ВВГгнг(А)-LS (VVGgng(A)-LS)

ВВГгнг(А)-LS (VVGgng(A)-LS)
Price on request
₽0
By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVGgng(A)-LS
Cables with circular conductors
with copper conductor
Number and nom. cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
1x16/16 20 631
1x25/16. 21,3 743
1x35/16 22,4 862
1x50/16 23,5 1033
1x70/16 25 1254
1x95/16 26,8 1522
1x120/16 28 1785
1x150/25 30,1 2178
1x185/25 31,9 2541
1x240/25 34,1 3097
1x300/25 36,3 3696
1x400/35 39,4 4767
1x500/35 42,1 5743
1x630/35 45,9 7041
1x800/35 49,6 8676
3x16/16 35 1607
3x25/16 37,9 1997
3x35/16 40,1 2400
3x50/16 43,1 2978
3x70/16 47 3767
3x95/16 50,5 4669
3x120/16 53,4 5586
3x150/25 57,1 6674
3x185/25 60,8 7875
3x240/25 65,5 9767
VVGgng(A)-LS
Cables with sector-shaped conductors
with copper conductor
Number and nom. cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 37,1
3x50/16 39,2 2425
3x70/16 41,9 3048
3x95/16 44,5 3812
3x120/16 47,5 4614
3x150/25 50 5593
3x185/25 52,9 6640
3x240/25 57,4 8321

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 6kV of frequency 50 Hz for networks with the earthed and insulated neutral.

The climate modification УХЛ, categories of location 1 and 5 according to GOST 15150, including installation in the ground.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.2.2.

STRUCTURE

Conductor

Copper, single-wire or multi-wire, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

Is made of PVC-compound of low fire hazard (color coded conductor).

Core arrangement

Insulated conductors of multi-core cables are twisted in a cable core.

Inner sheath

It is made by extrusion with PVC-compound of low fire hazard or chalk-filled non-cured rubber with the filling of outer gaps between insulated conductors. It is possible to fill the outer gaps between circular insulated cores with the bundles of with the lapping of fastening tape and extrusion inner sheath. It is allowed to wrap the cable core with the tapes of polymer material.

Taping

Layer of water blocking tapes.

Screen

Of copper wires and a spirally imposed copper tape. It is allowed the application of the screen with copper tapes.

Separating layer

Layer of water blocking tapes.

Over sheath

Of PVC-compound of low fire hazard.

By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVGgng(A)-LS
Cables with circular conductors
with copper conductor
Number and nom. cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
1x16/16 20 631
1x25/16. 21,3 743
1x35/16 22,4 862
1x50/16 23,5 1033
1x70/16 25 1254
1x95/16 26,8 1522
1x120/16 28 1785
1x150/25 30,1 2178
1x185/25 31,9 2541
1x240/25 34,1 3097
1x300/25 36,3 3696
1x400/35 39,4 4767
1x500/35 42,1 5743
1x630/35 45,9 7041
1x800/35 49,6 8676
3x16/16 35 1607
3x25/16 37,9 1997
3x35/16 40,1 2400
3x50/16 43,1 2978
3x70/16 47 3767
3x95/16 50,5 4669
3x120/16 53,4 5586
3x150/25 57,1 6674
3x185/25 60,8 7875
3x240/25 65,5 9767
VVGgng(A)-LS
Cables with sector-shaped conductors
with copper conductor
Number and nom. cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 37,1
3x50/16 39,2 2425
3x70/16 41,9 3048
3x95/16 44,5 3812
3x120/16 47,5 4614
3x150/25 50 5593
3x185/25 52,9 6640
3x240/25 57,4 8321