Products

Search by features


КППГЭнг(А)-HF (KPPGЕng(A)-HF)

КППГЭнг(А)-HF (KPPGЕng(A)-HF)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Shielded
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGЕng(A)-HF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х0,75 10,1 135
5х0,75 10,7 155
7х0,75 11,3 180
10х0,75 13,3 236
14х0,75 14,1 288
19х0,75 15,3 354
27х0,75 17,5 465
37х0,75 19,6 609
52х0,75 22,4 803
4х1,0 10,5 150
5х1,0 11,1 173
7х1,0 11,8 204
10х1,0 13,9 270
14х1,0 14,8 332
19х1,0 16,0 412
27х1,0 18,9 565
37х1,0 20,7 719
52х1,0 24,1 978
4х1,5 11,1 175
5х1,5 11,7 205
7х1,5 12,5 245
10х1,5 14,8 327
14х1,5 15,8 409
19х1,5 17,2 513
27х1,5 20,3 708
37х1,5 22,3 909
4х2,5 12,0 223
5х2,5 12,8 265
7х2,5 13,6 323
10х2,5 16,3 438
14х2,5 17,5 558
19х2,5 19,5 731
27х2,5 22,6 988
37х2,5 25,4 1311
4х4 13,6 306
5х4 14,6 369
7х4 15,6 459
10х4 19,4 649
4х6 14,8 393
5х6 15,9 476
7х6 17,1 604
10х6 21,4 858

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage 660V of frequency 100 Hz or direct voltage up to 1000V.

The cables are used at group installation of cable lines of power and control circuits. The cables are designed for large thermal power stations, petrochemical objects, in the subway, in buildings and structures with mass stay of people, concert halls and indoor stadiums, theatres, airports and railway stations; in premises, equipped with computer and microprocessor appliances and other objects which have increased requirements for fire safety.

The screened cables are used when it is necessary to protect the electrical circuits from the influence of external electric fields.

The class of fire hazard of the cables according to GOST 31565 of cables of modification "ng(A)-HF"- П1б.8.1.2.1.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

Halogen-free polymer composition.

Core arrangement

From 4 to 127 insulated conductors.

The insulated conductors are twisted; there is a marker pair in each layer. It is allowed digital and color coded marking of the conductors.

Separating layer

Halogen-free polymer composition.

Screen

For cables of types KPPGЕng(A)-HF - foiled alum flex with the contact conductor with a copper, galvanized wire.

Over sheath or jacket

Halogen-free polymer composition.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Shielded
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGЕng(A)-HF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х0,75 10,1 135
5х0,75 10,7 155
7х0,75 11,3 180
10х0,75 13,3 236
14х0,75 14,1 288
19х0,75 15,3 354
27х0,75 17,5 465
37х0,75 19,6 609
52х0,75 22,4 803
4х1,0 10,5 150
5х1,0 11,1 173
7х1,0 11,8 204
10х1,0 13,9 270
14х1,0 14,8 332
19х1,0 16,0 412
27х1,0 18,9 565
37х1,0 20,7 719
52х1,0 24,1 978
4х1,5 11,1 175
5х1,5 11,7 205
7х1,5 12,5 245
10х1,5 14,8 327
14х1,5 15,8 409
19х1,5 17,2 513
27х1,5 20,3 708
37х1,5 22,3 909
4х2,5 12,0 223
5х2,5 12,8 265
7х2,5 13,6 323
10х2,5 16,3 438
14х2,5 17,5 558
19х2,5 19,5 731
27х2,5 22,6 988
37х2,5 25,4 1311
4х4 13,6 306
5х4 14,6 369
7х4 15,6 459
10х4 19,4 649
4х6 14,8 393
5х6 15,9 476
7х6 17,1 604
10х6 21,4 858