Products

Search by features


КВВГзнг(А) (KVVGzng(A))

КВВГзнг(А) (KVVGzng(A))
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А))
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVVGzng(A)
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 7,5 96
5х1,0 8,2 115
7х1,0 9,4 157
10х1,0 11,5 216
14х1,0 12,4 271
19х1,0 13,7 344
27х1,0 16,1 466
37х1,0 17,9 605
52х1,0 21,3 842
4х1,5 8,1 119
5х1,5 9,4 157
7х1,5 10,1 196
10х1,5 12,4 272
14х1,5 13,4 346
19х1,5 14,8 442
27х1,5 17,5 603
37х1,5 19,9 809
4х2,5 9,6 178
5х2,5 10,4 215
7х2,5 11,2 273
10х2,5 14 381
14х2,5 15,1 492
19х2,5 16,7 635
27х2,5 20,3 895
37х2,5 22,6 1177
4х4 11,2 258
5х4 12,2 316
7х4 13,2 406
10х4 16,6 578
4х6 12,4 346
5х6 13,5 422
7х6 14,7 551
10х6 19 808

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz or direct voltage up to 1000V for installation in the premises, conduits, tunnels, in conditions of aggressive environment, in the absence of mechanical effects on cable.

It is possible to lay the cable in the ground (trenches) where the places of the exit of the cable from the ground to the surface are protected. The cables are used for installation in cable structures and spaces for providing of fire safety.

The cables of type KVVGzng(A) are used for installations requiring seal cables when entering.

The class of fire hazard of the cables according to GOST 31565 01.8.2.5.4.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

PVC-compound.

Core arrangement

From 4 to 127 insulated conductors.

The insulated conductors are twisted; there is a marker pair in each layer.

Separating layer

PVC-compound or a layer with the PET tape.

Over sheath or jacket

PVC-compound of low flammability

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А))
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVVGzng(A)
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 7,5 96
5х1,0 8,2 115
7х1,0 9,4 157
10х1,0 11,5 216
14х1,0 12,4 271
19х1,0 13,7 344
27х1,0 16,1 466
37х1,0 17,9 605
52х1,0 21,3 842
4х1,5 8,1 119
5х1,5 9,4 157
7х1,5 10,1 196
10х1,5 12,4 272
14х1,5 13,4 346
19х1,5 14,8 442
27х1,5 17,5 603
37х1,5 19,9 809
4х2,5 9,6 178
5х2,5 10,4 215
7х2,5 11,2 273
10х2,5 14 381
14х2,5 15,1 492
19х2,5 16,7 635
27х2,5 20,3 895
37х2,5 22,6 1177
4х4 11,2 258
5х4 12,2 316
7х4 13,2 406
10х4 16,6 578
4х6 12,4 346
5х6 13,5 422
7х6 14,7 551
10х6 19 808