Search by features
-
Power cables of nominal voltage up to 3kv
- Power cables for single installation
- VVG, AVVG, VVGE, AVVGE, VBShV, AVBShV, according to specification 16-705.4992010
- VVG-P, AVVG-P, according to specification 16-705.499-2010
- VVG, AVVG, VVGz, AVVGz, VBbShV, AVBbShV, VVG-P, AVVG-P, according to GOST 16442-80
- VVG-KhL, AVVG-KhL, VVGE-KhL, AVVGE-KhL, VBShv-KhL, AVBShv-KhL, VVG-P-KhL, AVVG-P-KhL
- VVGg-KhL, AVVGg-KhL, VVGEg-KhL, AVVGEg-KhL, VBShvg-KhL, AVBShvg-KhL, according to specification 16.K121-017-2011
- VBaShv-KhL, AVBaShv-KhL, VKaShv-KhL, VKShv-KhL, AVKShv-KhL, AVKaShv-KhL, according to specification 16.K121-017-2011
- PvVG, APvVG, PvVGE, APvVGE, PvBShv, APvBShv, PvVG-P, APvVG-P, PvBShP, APvBShP, according to specification 16-705.499-2010
- PvVG-KhL, APvVG-KhL, PvVGE-KhL, APvVGE -KhL, PvVG-P-KhL, APvVG-P-KhL, PVBShv-KhL, APVBShv-KhL, PVBaShv-KhL, APVBaShv-KhL, PvKShv-KhL, APvKShv-KhL, PvKaShv-KhL, APvKaShv-KhL, according to specification 16.K121-017-2011
- ПвВГ-ХЛ (PvVG-KhL)
- АПвВГ-ХЛ (APvVG-KhL)
- ПвВГЭ-ХЛ (PvVGE-KhL)
- АПвВГЭ-ХЛ (APvVGE-KhL)
- ПвВГ-П-ХЛ (PvVG-P-KhL)
- АПвВГ-П-ХЛ (APvVG-P-KhL)
- ПвБШв-ХЛ (PvBShv-KhL)
- АПвБШв-ХЛ (APvBShv-KhL)
- ПвБаШв-ХЛ (PvBaShv-KhL)
- АПвБаШв-ХЛ (APvBaShv-KhL)
- ПвКШв-ХЛ (PvKShv-KhL)
- АПвКШв-ХЛ (APvKShv-KhL)
- ПвКаШв-ХЛ (PvKaShv-KhL)
- АПвКаШв-ХЛ (APvKaShv-KhL)
- NYM-J, NYM-O according to specifications 3521-002-53972660-2007
- NY(F)2Y-J
- Power cables flame retardant at group installation (modification "flame retardant")
- Power cables with plastic insulation flame retardant at group installation in cold-resistant modification
- VVGng(A)-KhL, AVVGng(A)-KhL, VVGEng(A)-KhL, AVVGEng(A)-KhL, VBShvng(A)–KhL, АVBShvng(A), VVG-Png(A)-KhL, AVVG-Png(A)-KhL, according to specifications 16.K121-017-2011
- VBAShvng (A)-KhL, AVBAShvng(A)-KhL, VKShvng(A)-KhL, AVKShvng(A)-KhL, VKaShvng(A)-KhL, AVKaShvng(A)-KhL, according to specifications 16.K121-017-2011
- PvVGng(A)-KhL, APvVGng(A)-KhL, PvVG-Png(A)-KhL, APvVG-Png(A)-KhL, PvVGEng(A)-KhL, APvVGEng(A)-KhL, PvBShvng(A)-KhL, APvBShvng(A)-KhL, PvBaShvng(A)-KhL, APvBaShvng(A)-KhL, PvKShvng(A)-KhL, APvKShvng(A)-KhL, PvKaShvng(A)-KhL, APvKaShvng(A)-KhL
- ПвВГнг(А)-ХЛ (PvVGng(A)-KhL)
- АПвВГнг(А)-ХЛ (APvVGng(A)-KhL)
- ПвВГ-Пнг(А)-ХЛ (PvVG-Png(A)-KhL)
- АПвВГ-Пнг(А)-ХЛ (APvVG-Png(A)-KhL)
- ПвВГЭнг(А)-ХЛ (PvVGEng(A)-KhL)
- АПвВГЭнг(А)-ХЛ (APvVGEng(A)-KhL)
- ПвБШвнг(А)-ХЛ (PvBShvng(A)-KhL)
- АПвБШвнг(А)-ХЛ (APvBShvng(A)-KhL)
- ПвБаШвнг(А)-ХЛ (PvBaShvng(A)-KhL)
- АПвБаШвнг(А)-ХЛ (APvBaShvng(A)-KhL)
- ПвКШвнг(А)-ХЛ (PvKShvng(A)-KhL)
- АПвКШвнг(А)-ХЛ (APvKShvng(A)-KhL)
- ПвКаШвнг(А)-ХЛ (PvKaShvng(A)-KhL)
- АПвКаШвнг(А)-ХЛ (APvKaShvng(A)-KhL)
- VGng (A)-KhL, AVVGng (A)-KhL, VVGEng (A)-KhL, AVVGEng (A)-KhL, VBShVng (A)–KhL, AVBShVng (A)–KhL, VBaShVng (A)–KhL, AVBaShVng (A)–KhL, VeBShvng (A)–KhL, AVeBShvng (A)–KhL, VeBShvng (A)–KhL, АVeBShvng (A)–KhL, according to specifications 16.K121-027-20133
- ВВГнг(А)-ХЛ (VVGng(A)-KhL)
- АВВГнг(А)-ХЛ (AVVGng(A)-KhL)
- ВВГЭнг(А)-ХЛ (VVGEng(A)-KhL)
- АВВГЭнг(А)-ХЛ (AVVGEng(A)-KhL)
- ВБШвнг(А)-ХЛ (VBShVng(A)–KhL)
- АВБШвнг(А)-ХЛ (AVBShVng(A)–KhL)
- ВБаШвнг(А)-ХЛ (VBaShVng(A)–KhL)
- АВБаШвнг(А)-ХЛ (AVBaShVng(A)–KhL)
- ВЭБШвнг(А)-ХЛ (VEBShvng(A)–KhL)
- АВЭБШвнг(А)-ХЛ (AVEBShvng(A)–KhL)
- ВЭБаШвнг(А)-ХЛ (VEBaShvng(A)–KhL)
- АВЭБаШвнг(А)-ХЛ (АVEBaShvng(A)–KhL)
- VVGgng(A)-KhL, AVVGgng(A)-KhL, VVGEgng(A)-KhL, AVVGEgng(A)-KhL, VBShVgng(A)–KhL, AVBShVgng(A)–KhL, VBaShVgng(A)–KhL, AVBaShVgng(A)–KhL, VeBShvgng(A)–KhL, AVeBShvgng(A)–KhL, VeBShvgng(A)–KhL, АVeBShvgng(A)–KhL
- ВВГгнг(А)-ХЛ (VVGgng(A)-KhL)
- АВВГгнг(А)-ХЛ (AVVGgng(A)-KhL)
- ВВГЭгнг(А)-ХЛ (VVGEgng(A)-KhL)
- АВВГЭгнг(А)-ХЛ (AVVGEgng(A)-KhL)
- ВБШвгнг(А)-ХЛ (VBShvgng(A)-KhL)
- АВБШвгнг(А)-ХЛ (AVBShvgng(A)-KhL)
- ВБаШвгнг(А)-ХЛ (VBaShvgng(A)-KhL)
- АВБаШвгнг(А)-ХЛ (AVBaShvgng(A)-KhL)
- ВЭБШвгнг(А)-ХЛ (VEBShvgng(A)-KhL)
- АВЭБШвгнг(А)-ХЛ (AVEBShvgng(A)-KhL)
- ВЭБаШвгнг(А)-ХЛ (VEBaShvgng(A)-KhL)
- АВЭБаШвгнг(А)-ХЛ (АVEBaShvgng(A)-KhL)
- VVG-Png(A)-Kh-L, AVVG-Png(A)-Kh-L, VVG-Pgng(A)-Kh-L, AVVG-Pgng(A)-Kh-L, according to specifications 16.K121-027-2013
- Power cables with plastic insulation, flame retardant at group installation with low smoke- and gas emission
- VVGng(A)-LS, AVVGng(A)-LS, VVGEng(A)-LS, AVVGEng(A)-LS, VBShvng(A)-LS, AVBShvng(A)-LS, according to specifications 16 .K71-310-2001
- VVG-Png(A)-LS, AVVG-Png(A)-LS, according to specifications respectively, 16.K71-310-2001
- VVGng(A)-LS, AVVGng(A)-LS, VVGEng(A)-LS, AVVGEng(A)-LS, VBShvng(A)-LS, AVBShvng(A)-LS, according to specifications 16 .K121-018-2011
- VVG-Png(A)-LS, AVVG-Png(A)-LS, according to specifications 16.K121-018-2011
- PvVGng(A)-LS, APvVGng(A)-LS, PvVGЕng(A)-LS, APvVGЕng(A)-LS, PvBShvng(A)-LS, АPvBShvng(A)-LS, according to specifications 16 .K121-018-2011
- PvVGng(A)-LS, PvVGЕng(A)-LS,PvBShvng(A)-LS according to specifications 16.K71-480-2015
- Power cables with xlpe insulation, flame retardant at group installation with low smoke- and gas emission
- Power cables, flame retardant at group installation and not emitting corrosive active gaseous products at burning and smouldering (modification "flame retardant – halogen-free")
- PPGng(A)-HF, PPGEng(A)-HF, PBPng(A)-HF, PPGgng(A)-HF, PPGEgng(A)-HF, PBPgng(A)-HF, according to specifications 16.K121-023-2011
- PvPGng(A)-HF, PvPGEng(A)-HF, according to specifications 16.K71-341-2004
- PPGng(A)-HF, PPGЕng(A)-HF, PBPng(A)-HF, PvPGng(A)-HF, according to specifications 16.K71-304-2001
- PvPGng(A)-HF, PvPGEng(A)-HF, PvBPng(A)-HF, according to specifications 16.K71-480-2015
- Power cables, fire-resisting, flame retardant at group installation, with low smoke- and gas emission (modification "flame retardant – "fire-resistant low smoke")
- VVGng(A)-FRLS, VVGЕng(A)-FRLS, VBShvng(A)-FRLS, VVG-Png(A)-FRLS, according to specifications 16.K121-022-2011
- VVGng(A)-FRLS, VVGЕng(A)-FRLS, according to specifications 16.K71-337-2004
- PvVGng(A)-FRLS, PvVGEng(A)-FRLS, PvBShvng(A)-FRLS, according to specifications 16.K121-022-2011
- PvVGng(A)-FRLS, according to specifications 16.K71-341-2004
- RVGng(A)-FRLS, RVG-Рng(A)-FRLS, RVGЕng(A)-FRLS, according to specifications 16.K121-026-2013
- PvVGng(A)-FRLS, PvVGEng(A)-FRLS, PvBShvng(A)-FRLS according to specifications 16.K71-480-2015
- Low-toxic power cables flame retardant at group installation with low smokeand gas emission
- Power cables fire-resistant flame retardant at group installation, which do not emmit toxic corrosive active gaseous products while burning and smouldering (modification "flame retardant – fire-resistant halogen-free")
- PvPGng(A)-FRHF, PvPGЕng(A)-FRHF, according to specifications 16.K71-341-2004
- PvPGng-FRHF, PvPGEng-FRHF, PvBPng-FRHF, PvPGgng-FRHF, PvPGEgng-FRHF, PvBPgng-FRHF, according to specifications 16.K121-023-2011
- PPGng(A)-FRHF, PPGЕng(A)-FRHF, PBPng(A)-FRHF, according to specifications 16.K71-341-2004
- PPGng(A)-FRHF, PPGЕng(A)-FRHF, PvPGng(A)-FRHF, PvPGEng(A)-FRHF, according to specifications 16.K71-339-2014
- RPGng(A)-FRHF, RPGEng(A)-FRHF, RPG-Png(A)-FRHF, according to specifications 16.K121-026-2013
- PvPGng(A)-FRHF, PvPGEng(A)-FRHF, PvBPng(A)-FRHF according to specifications16.K71-480-2015
- Power cables fire-resisting with plastic insulation flame retardant at group installation in cold-resistant modification with the temperature of cable installation up to -30 degrees below zero
- Power cables for single installation
-
Power cables for rated voltage up to 6 kV
- VVG, AVVG, VVGg, AVVGg, VBV, AVBV, VBVg, AVBVg, according to specifications 16.K121-028-2013
- PvPGng(A)-HF, PvPGng(A)-HF according to specifications 16.K71-480-2015
- KVEBShv, KVEBShv(u), according to specifications 16.K121-024-2013
- VVG, AVVG, VBV, АVBV, according to specifications 16.K71-359-2005
- KVEBShvng(A), KVEBShv(u)ng(A), according to specifications 16. K121-024-2013
- VVGng(A), AVVGng(A), VVGgng(A), AVVGgng(A), VBVng(A), AVBVng(A), VBVgng(A), AVBVgng(A), according to specifications 16.K121-028-2013
- VBVng(A), AVBVng(A), according to specifications 16.K71-359-2005
- KVEBShv-KhL, KVEBShv(u)-KhL, according to specifications 16.K121-024-2013
- KVEBShvng(A)KhL, KVEBShv(u)ng(A)KhL, according to specifications 16.K121-024-2013
- VVGng(A)-LS, AVVGng(A)-LS, VVGgng(A)-LS, АVVGgng(A)-LS, VBVng(A)-LS, AVBVng(A)-LS, VBVgng(A)-LS, AVBVgng(A)-LS, according to specifications 16.K121-028-2013
- KVEBShvng(A)-FRLS, KVEBShv(u)ng(A)-FRLS according to specifications 16.K121-024-2013
- KVEBShvng(A)-FRKhL, KVEBShv(u)ng(A)-FRKhL according to specifications 16.K121-024-2013
- PvVGng(A)-LS, PvBShvng(A)-LS according to specifications 16.K71-480-2015
-
Control cables
- KVVG, KVVGz, KVVGE, KVBbShv, according to GOST 1508-78
- KVVGng(A), KVVGzng(A), KVVGЕng(A), KVBbShvng(A), KVBbShvzng(A), according to specifications 3563-004-53972660-2008
- KVVGng(A)-KhL, KVVGzng(A)-KhL, KVVGЕng(A)-KhL, KVBbShvng(A)-KhL, KVVG-Png(A)-KhL, according to specifications 16.K121-012-2013
- KVVGng(A)-KhL, KVVGЕng(A)-KhL, KVBbShvng(A)-KhL, KVVGgng(A)-KhL, KVVGЕgng(A)-KhL, KVBbShvgng(A)-KhL, according to specifications 16.K121-030-2013
- KVVGng(A)- FRLSLTx, KVVGЕng(A)- FRLSLTx, KVBbShvng(A)- FRLSLTx according to specifications 3563-010-53972660-2010
- KVVGng(A)-LS, KVVGEng(A)-LS, according to specifications 16.K71-310-2001
- KVVGng(A)-LS, KVVGzng(A)-LS, KVVGЕng(A)-LS, KVBbShvng(A)-LS, KVVG-Png(A)-LS, according to specifications 3563-010-53972660-2010
- KPPGng(A)-HF, KPPGЕng(A)-HF, KPBPng(A)-HF, according to specifications 16.K71-304-2001
- KPPGng(A)-HF, KPPGЕng(A)-HF, KPBbPng(A)-HF, according to specifications 16.K121-029-2013
- KVVGng(A)-FRLS, KVVGЕng(A)-FRLS, according to specifications 16.K71-337-2004
- KVVGng(A)-FRLS, KVVGЕng(A)-FRLS, KVBbShvng(A)-FRLS, according to specifications 3563-010-53972660-2010
- KPPGng(A)-FRHF, KPPGЕng(A)-FRHF, according to specifications 16.K71-339-2004
- KPPGng(A)-FRHF, KPPGЕng(A)-FRHF, KPBbPng(A)-FRHF, according to specifications 16.K121-029-2014
- KPBPng(A)- FRHF, KPvBPng(A)-FRHF according to specifications 16.K71-480-2015
- KVVGng(A)-FRKhL, KVVGЕng(A)-FRKhL, KVBbShvng(A)-FRKhL, according to specifications 16.K121-030-2013
- KPBShvng(A)-FRLS, KPvBShvng(A)-FRLS according to specifications 16.K71-480-2015
- KPBPng(A)- HF, KPvBPng(A)- HF according to specifications 16.K71-480-2015
- KPBShvng(A)-LS, KPvBShvng(A)-LS according to specifications 16.К71-480-2015
- KVVGng(A)- LSLTx, KVVGzng(A)- LSLTx, KVVGЕng(A)- LSLTx, KVBbShvng(A)- LSLTx, KVVG-Png(A)- LSLTx according to specifications 3563-010-53972660-2010
- Wires, cords and connecting cables
-
Wires and cables for electrical units
- PuV, PuGV, PuVV, PuGVV, KuVV, KuGVV, according to specifications 16-705.501-2010
- PV1, PV1-KhL, PV2, PV2-KhL, PV3, PV3-KhL, PV4, PV4-KhL, PPV, PPV-KhL, АPV, АPV-KhL, according to GOST 6323-79
- PuVng(A)-LS, PuGVng(A)-LS, PuVVng(A)-LS, PuGVVng(A)-LS, KuVVng(A)-LS, KuGVVng(A)-LS, according to specifications 16-705.502-2011
- KuRVng(A)-FRLS, KuGRVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuREVng(A)-FRLS, KuGREVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuRKVng(A)-FRLS, KuGRKVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuREVKVng(A)-FRLS, KuGREVKVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuRPng(A)-FRHF, KuGRPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuREPng(A)-FRHF, KuGREPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuRKPng(A)-FRHF, KuGRKPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuREPKPng(A)-FRHF, KuREPKPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuRVng(A)-FRLSTx, KuGRVng(A)-FRLSTx, according to specifications 16-K121-025-2013
- KuRKVng(A)-FRLSTx, KuGRKVng(A)-FRLSTx, according to specifications 16-K121-025-2013
- KuREVng(A)-FRLSTx, KuREVng(A)-FRLSTx, according to specifications 16-K121-025-2013
-
Cables for Fire Alarm Systems
- КPSVVng(А)-LS, КPSVVGng(А)-LS, КPSVEVng(А)-LS, КPSVEVGng(А)-LS, КPSVEEVng(А)-LS, КPSVEEVGng(А)-LS, according to specifications 16.K121-020-2011
- КPSng(А)-FRLS, КPSGng(А)-FRLS, КPSEng(А)-FRLS, КPSEGng(А)-FRLS, КPSEEng(А)-FRLS, КPSEEGng(А)-FRLS, according to specifications 16.K121-021-2011
- KPSng(A)-FRHF, KPSGng(A)-FRHF, KPSEng(A)-FRHF, KPSEGng(A)-FRHF, KPSEEng(A)-FRHF, KPSЕEGng(A)-FRHF, according to specifications 16.K121-021-2011
- KPSSng(A)-FRLS, KPSSGng(A)-FRLS, KPSESng(A)-FRLS, KPSESGng(A)-FRLS, according to specifications 16.K121-021-2011
- KPSSng(A)-FRHF, KPSSGng(A)-FRHF, KPSESng(A)-FRHF, KPSESGng(A)-FRHF, according to specifications 16.K121-021-2011
- KPSSng(A)-FRLSLTx, KPSSGng(A)-FRLSLTx, KPSЕSng(A)-FRLSLTx,KPSЕSGng(A)-FRLSLTx according to specifications 16.K121-021-2011
-
Cables for monitoring and control circuits
- KUGVVng(A)-LS, KUGVEVng(A)-LS, KUGVVEng(A)-LS, according to specifications 16.K71-310-2001
- KUGVVng(A)-FRLS, KUGVEVng(A)-FRLS, KUGVVЕng(A)-LS, according to specifications 16.K71-337-2004
- KUPPng(A)-HF, KUPPlng(A)-HF, according to specifications 3561-411-00217053-2009
- KUPPmng(A)-HF, KUPPmng(A)-FRHF, KUPEfPmng(A)-HF, KUPEfPmng(A)-FRHF, according to specifications 3561-441-00217053-2012
- KUPPng(A)-FRHF, KUPPlng(A)-FRHF, according to specifications 3561-442-00217053-2012
- KUGPvEPvng(A)-HF-LOCA, KUGPvEPvng(A)-HF-T-LOCA, KUGPvEPvng(A)-FRHF-LOCA, KUGPvEPvng(A)-FRHF-T-LOCA, KUGPvEPvng(A)-HF, KUGPvEPvng(A)-HF-T, KUGPvEPvng(A)-FRHF, KUGPvEPvng(A)-FRHF-T according to specifications 16.К71-451-2012
- КУГПвЭПвнг(А)-HF-LOCA (KUGPvEPvng(A)-HF-LOCA)
- КУГПвЭПвнг(А)-HF (KUGPvEPvng(A)-HF)
- КУГПвЭПвнг(А)-HF-Т-LOCA (KUGPvEPvng(A)-HF-T-LOCA)
- КУГПвЭПвнг(А)-HF-Т (KUGPvEPvng(A)-HF-T)
- КУГПвЭПвнг(А)-FRHF-LOCA (KUGPvEPvng(A)-FRHF-LOCA)
- КУГПвЭПвнг(А)-FRHF (KUGPvEPvng(A)-FRHF)
- КУГПвЭПвнг(А)-FRHF-Т-LOCA (KUGPvEPvng(A)-FRHF-T-LOCA)
- КУГПвЭПвнг(А)-FRHF-Т (KUGPvEPvng(A)-FRHF-T)
- Small-size cables
-
Cables for control systems and alarm
- KPEPng(A)-HF, KGPEPng(A)-HF, KUGPPng(A)-HF, KUGPPEng(A)-HF, KUGPPEPng(A)-HF, KUGPEPng(A)-HF, KUGEPPng(A)-HF, KUGEPPEng(A)-HF, KUGEPPEPng(A)-HF, according to specifications 16.K71-338-2004
- KPEPng(A)-FRHF, KGPEPng(A)-FRHF, KUGPPng(A)-FRHF, KUGPPЕng(A)-FRHF, KUGPPЕРng(A)-FRHF, KUGPЕРng(A)-FRHF, KUGЕРРng(A)-FRHF, KUGЕРРЕng(A)-FRHF, KUGЕРРЕРng(A)-FRHF, according to specifications 16.K71-338-2004
- КПЭПнг(А)-FRHF (KPEPng(A)-FRHF)
- КГПЭПнг(А)-FRHF (KGPEPng(A)-FRHF)
- КУГППнг(А)-FRHF (KUGPPng(A)-FRHF)
- КУГППЭнг(А)-FRHF (KUGPPЕng(A)-FRHF)
- КУГППЭПнг(А)-FRHF (KUGPPЕРng(A)-FRHF)
- КУГПЭПнг(А)-FRHF (KUGPЕРng(A)-FRHF)
- КУГЭППнг(А)-FRHF (KUGЕРРng(A)-FRHF)
- КУГЭППЭнг(А)-FRHF (KUGЕРРЕng(A)-FRHF)
- КУГЭППЭПнг(А)-FRHF (KUGЕРРЕРng(A)-FRHF)
-
Telephone cables
- TVBPng(A)-HF – Russian analogue of J-2YF(St)H… Bd, А-2YF(L)H..BD, TVBPBbPng(A)-HF – Russian analogue of J-2YF(St)BH according to Specification 16.K71-468-2015
- TVBVng(A)-LS – Russian analogue of J-2YF(St)Y… Bd, А-2YF(L)Y..BD Flame Retardant Low Smoke, TVBVBbShvng(A)-LS – Russian analogue of J-2YF(St)BY Flame Retardant Low Smoke according to Specification 16.K71-468-2015
ВВГЭнг(А)-ХЛ (VVGEng(A)-KhL)
- By category
- Force cables
- Voltage
- 660 / 1000
- In execution
- Flame retardant (-ng(А)) / Cold-resistant (-HL) / Shielded
- Insulation
- Copper
- Shell
- PVC insulation
- Core material
- Flexible PVC
SCOPE AND PURPOSE
The cables are designed for transmission and distribution of electric energy in stationary electric installations on alternating voltage 0,66 and 1 kV and frequency 50 Hz or for direct voltage of 1 and 1.5 kV correspondingly.
The cables are used for group installation in cable constructions, openair electrical installations (cable overpasses, arcades).
While manufacturing the cables one uses the materials, which allow the cables to be resistant to low temperatures up to – 600C (degrees below zero) are used.
The class of fire hazard of the cables according to GOST 31565 П1б.8.2.5.4.
STRUCTURE
Conductor
Copper core of circular of sector-shaped form, of the 1 or 2 class according to GOST 22483.
Insulation
PVC-compound (color coded conductor)
Core arrangement and stranding
Insulated conductors of 2, 3, 4, 5 and 6 core cables twisted in cable core.
In cables of types VVG-Png(A)-KhL and AVVG-Png(A)-KhL the cores are situated in parallel in flat formation.
Inner sheath
PVC-compound or PVC-compound of low flammability is manufactured with the filling of exterior gaps between insolated conductors.
Screen
For cables of types VVGEng(A)-KhL a screen is made of copper tapes or copper wires and a spiral taping with a copper tape.
Cable sheath or jacket
PVC-compound of low flammability
- By category
- Force cables
- Voltage
- 660 / 1000
- In execution
- Flame retardant (-ng(А)) / Cold-resistant (-HL) / Shielded
- Insulation
- Copper
- Shell
- PVC insulation
- Core material
- Flexible PVC