РПГ-Пнг(А)-FRHF (RPG-Png(A)-FRHF)

РПГ-Пнг(А)-FRHF (RPG-Png(A)-FRHF)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Shell
Silicon rubber
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
 width  height
2х1,5ок(N)-0,66  7,9 5,1 70
2х2,5ок(N)-0,66  8,7 5,4 92
2х4ок(N)-0,66  10,0 6,1 131
2х6ок(N)-0,66  11,0 6,6 173
3х1,5ок(N,PE)-0,66  10,8 5,1 100
3х2,5ок(N,PE)-0,66  11,9 5,4 132
3х4ок(N,PE)-0,66  13,9 6,1 190
3х6ок(N,PE)-0,66  15,4 6,6 252
2х1,5ок(N)-1  8,7 5,5 79
2х2,5ок(N)-1 9,5 5,8 102
2х4ок(N)-1  10,8 6,5 142
2х6ок(N)-1  11,8 7,0 184
3х1,5ок(N,PE)-1  12,0 5,5 112
3х2,5ок(N,PE)-1  13,1 5,8 146
3х4ок(N,PE)-1  15,1 6,5 205
3х6ок(N,PE)-1 16,6 7,0 268

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 0.66 and 1kV and frequency 50 Hz. The cables do not spread combustion at the group stationary installation of cable power lines in the absence of danger of mechanical impact on the cable and it keeps working in case of fire during 180 minutes.

The cables are designed for wiring and emergency power circuits of equipment (current collectors), in residential and public buildings, in the surgical departments of hospitals, in the office premises, equipped with computer and micro processor devices, spectacular complexes and sports facilities, as well as in other objects with the high demand of fire safety.

The cables of types RPG-Png(A)-FRHF are used for installation under plaster, where a seal is not required when entering.

The class of fire hazard of the cables according to GOST 31565 П1б.1.1.2.1.

STRUCTURE

Number of conductors

2 or 3.

Conductor

Copper, of circular form, single-wire core with the cross-section from 1.5 to 16mm2 or multiwire core with the cross-section from 10 to 16mm2.

Insulation

Ceramic forming silicon rubber.

Core arrangement and twisting

Insulated cores are arranged in parallel in one flat.

Over sheath

Halogen-free polymer composition.

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Shell
Silicon rubber
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
 width  height
2х1,5ок(N)-0,66  7,9 5,1 70
2х2,5ок(N)-0,66  8,7 5,4 92
2х4ок(N)-0,66  10,0 6,1 131
2х6ок(N)-0,66  11,0 6,6 173
3х1,5ок(N,PE)-0,66  10,8 5,1 100
3х2,5ок(N,PE)-0,66  11,9 5,4 132
3х4ок(N,PE)-0,66  13,9 6,1 190
3х6ок(N,PE)-0,66  15,4 6,6 252
2х1,5ок(N)-1  8,7 5,5 79
2х2,5ок(N)-1 9,5 5,8 102
2х4ок(N)-1  10,8 6,5 142
2х6ок(N)-1  11,8 7,0 184
3х1,5ок(N,PE)-1  12,0 5,5 112
3х2,5ок(N,PE)-1  13,1 5,8 146
3х4ок(N,PE)-1  15,1 6,5 205
3х6ок(N,PE)-1 16,6 7,0 268