Products

Search by features


ВВГ-Пнг(А)-LS (VVG-Png(A)-LS)

ВВГ-Пнг(А)-LS (VVG-Png(A)-LS)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-Png(A)-LS, 0,66 kV
Number of conductors, nominal cross-section (mm<sup>2</sup>) Calculated diameter of cable, mm Calculated weight of cable, kg/km
height width
2х1,5 5,3 7,9 81
2х2,5 5,6 8,7 104
2х4 6,3 10,0 146
2х6 6,8 11,0 189
2х10 8,0 13,4 290
2х16 9,1 15,4 417
3х1,5 5,3 10,6 113
3х2,5 5,6 11,7 148
3х4 6,3 13,7 209
3х6 6,8 15,2 274
3х10 8,0 18,8 413
3х16 9,1 21,7 610
VVG-Png(A)-LS, 1 kV
Number of conductors, nominal cross-section (mm<sup>2</sup>) Calculated diameter of cable, mm Calculated weight of cable, kg/km
height width
2х1,5 5,7 8,7 92
2х2,5 6,0 9,5 116
2х4 6,9 11,2 166
2х6 7,4 12,2 211
2х10 8,2 13,8 298
2х16 9,3 15,8 426
3х1,5 5,7 11,8 128
3х2,5 6,0 12,9 164
3х4 6,9 15,5 238
3х6 7,4 17,0 305
3х10 8,2 19,4 435
3х16 9,3 22,3 624

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cable VVG-Png(A)-LS is designed for transmission and distribution of electric energy in stationary electric installations on alternating voltage 0,66 and 1kV and frequency 50 Hz.

The cables are used for electrical installations in residential and public buildings.

The cables are designed for use in cable structures and premises, including the objects where nuclear energy is used in the AC systems of classes 3 and 4 according to classification ОПБ-88 (ПНАЭГ–01-011-97).

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.2.2.

STRUCTURE

Conductor

Copper, single-wire, of circular form, of the 1 class according to GOST 22483.

Number of conductors

2 or 3

Nominal cross-section of the conductors, mm2

1.5-16

Insulation

PVC-compound of low flammability (color coded conductor).

Core arrangement

Insulated conductors laid in parallel in one flat.

Cable sheath

PVC-compound of low flammability

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-Png(A)-LS, 0,66 kV
Number of conductors, nominal cross-section (mm<sup>2</sup>) Calculated diameter of cable, mm Calculated weight of cable, kg/km
height width
2х1,5 5,3 7,9 81
2х2,5 5,6 8,7 104
2х4 6,3 10,0 146
2х6 6,8 11,0 189
2х10 8,0 13,4 290
2х16 9,1 15,4 417
3х1,5 5,3 10,6 113
3х2,5 5,6 11,7 148
3х4 6,3 13,7 209
3х6 6,8 15,2 274
3х10 8,0 18,8 413
3х16 9,1 21,7 610
VVG-Png(A)-LS, 1 kV
Number of conductors, nominal cross-section (mm<sup>2</sup>) Calculated diameter of cable, mm Calculated weight of cable, kg/km
height width
2х1,5 5,7 8,7 92
2х2,5 6,0 9,5 116
2х4 6,9 11,2 166
2х6 7,4 12,2 211
2х10 8,2 13,8 298
2х16 9,3 15,8 426
3х1,5 5,7 11,8 128
3х2,5 6,0 12,9 164
3х4 6,9 15,5 238
3х6 7,4 17,0 305
3х10 8,2 19,4 435
3х16 9,3 22,3 624