Products

Search by features


AВВГ-П (AVVG-P)

AВВГ-П (AVVG-P)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
For a single pad
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVG-P
Number of conductors Calculated dimensions of cable, mm Calculated weight of cable, kg/km
height width
2х2,5ок(N)-0,66 5,8 8,9 70
2х4ок(N)-0,66 6,5 10,2 93
2х6ок(N)-0,66 7 11,1 111
2х10ок(N)-0,66 8,1 13,5 160
2х16ок(N)-0,66 9,3 15,5 217
3х2,5ок(N,PE)-0,66 5,8 11,9 99
3х4ок(N,PE)-0,66 6,5 13,9 132
3х6ок(N,PE)-0,66 7 15,3 160
3х10ок(N,PE)-0,66 8,1 18,8 234
3х16ок(N,PE)-0,66 9,3 21,8 319
2х2,5ок(N)-1 6,2 9,7 81
2х4ок(N)-1 7,1 11,4 111
2х6ок(N)-1 7,6 12,3 131
2х10ок(N)-1 8,3 13,9 168
2х16ок(N)-1 9,5 15,9 226
3х2,5ок(N,PE)-1 6,2 13,1 114
3х4ок(N,PE)-1 7,1 15,7 159
3х6ок(N,PE)-1 7,6 17,1 189
3х10ок(N,PE)-1 8,3 19,4 245
3х16ок(N,PE)-1 9,5 22,4 332

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electricity in fixed electrical installations on a nominal alternating voltage 0,66, 1 and 3 kV, frequency - 50 Hz.

Cables of types AVVG-P are designed for laying single cable lines in cable installations and premises.

Cables of types AVVG-P in a single-conductor modification is designed for use in DC voltage.

The class of fire hazard of the cables is according to GOST 31565 01.8.2.5.4.

STRUCTURE

Conductor

Aluminum or copper core, single-wire, circular form, 1 class according to GOST 22483.

Numbers of conductors

2 or 3

Nominal cross-section area of main conductors, mm2

Copper 1,5-16

Aluminum 2,5-16

Stranding

Insulated cores are laid parallel in one flat.

Insulation

PVC- compound (color coded conductor).

Over sheath or protective covering

PVC-compound

By category
Force cables
Voltage
660 / 1000
In execution
For a single pad
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVG-P
Number of conductors Calculated dimensions of cable, mm Calculated weight of cable, kg/km
height width
2х2,5ок(N)-0,66 5,8 8,9 70
2х4ок(N)-0,66 6,5 10,2 93
2х6ок(N)-0,66 7 11,1 111
2х10ок(N)-0,66 8,1 13,5 160
2х16ок(N)-0,66 9,3 15,5 217
3х2,5ок(N,PE)-0,66 5,8 11,9 99
3х4ок(N,PE)-0,66 6,5 13,9 132
3х6ок(N,PE)-0,66 7 15,3 160
3х10ок(N,PE)-0,66 8,1 18,8 234
3х16ок(N,PE)-0,66 9,3 21,8 319
2х2,5ок(N)-1 6,2 9,7 81
2х4ок(N)-1 7,1 11,4 111
2х6ок(N)-1 7,6 12,3 131
2х10ок(N)-1 8,3 13,9 168
2х16ок(N)-1 9,5 15,9 226
3х2,5ок(N,PE)-1 6,2 13,1 114
3х4ок(N,PE)-1 7,1 15,7 159
3х6ок(N,PE)-1 7,6 17,1 189
3х10ок(N,PE)-1 8,3 19,4 245
3х16ок(N,PE)-1 9,5 22,4 332