ВВГ-Пнг(А)-LSTx (VVG-Png(A)-LSTx)

ВВГ-Пнг(А)-LSTx (VVG-Png(A)-LSTx)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Low toxicity (-LTx)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-Png(A)-LSTx
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
height width
2х1,5ок(N)-0,66 5,5 8,1 89
2х2,5ок(N)-0,66 5,8 8,9 114
2х4ок(N)-0,66 6,5 10,2 159
2х6ок(N)-0,66 7 11,2 204
2х10ок(N)-0,66 8,2 13,6 311
2х16ок(N)-0,66 9,3 15,6 443
3х1,5ок(N,PE)-0,66 5,5 10,8 125
3х2,5ок(N,PE)-0,66 5,8 11,9 163
3х4ок(N,PE)-0,66 6,5 13,9 229
3х6ок(N,PE)-0,66 7 15,4 297
3х10ок(N,PE)-0,66 8,2 19 459
3х16ок(N,PE)-0,66 9,3 21,9 656
2х1,5ок(N)-1 5,9 8,9 101
2х2,5ок(N)-1 6,2 9,7 127
2х4ок(N)-1 7,1 11,4 181
2х6ок(N)-1 7,6 12,4 228
2х10ок(N)-1 8,4 14 320
2х16ок(N)-1 9,5 16 454
3х1,5ок(N,PE)-1 5,6 12 144
3х2,5ок(N,PE)-1 6,2 13,1 182
3х4ок(N,PE)-1 7,1 15,7 263
3х6ок(N,PE)-1 7,6 17,2 334
3х10ок(N,PE)-1 8,4 19,6 473
3х16ок(N,PE)-1 9,5 22,5 672

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power in stationary electric installations on alternating voltage 0,66 and 1kV and frequency 50 Hz.

The cables are used in group installations; they do not spread combustion on category A.

The cables are designed for use in cable structures and premises, including residential and public buildings, in buildings of children’s preschool educational institutions, specialized homes for the elderly and persons with disabilities, hospitals, buildings of educational establishments of boarding schools and children’s institutions, hotels, dormitories, the dormitories sanatoriums and vacation houses of general type, motels, resorts and spectacular clubs, sports facilities, buildings of the organization for the maintenance of the population, of subways.

The class of fire hazard of the cables according to GOST 31565-2012 П1б.8.2.2.2.

STRUCTURE

Conductor

Copper, single-wire or multi-wire core, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation (color coded conductor).

It’s made of low toxicity PVC-compound of low flammability.

Core arrangement and twisting

2 or 3 conductors are situated in parallel in one flat.

Inner sheath

It’s made of low toxicity PVC-compound of low flammability

Cable sheath or jacket

It’s made of low toxicity PVC-compound of low flammability.

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Low toxicity (-LTx)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-Png(A)-LSTx
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
height width
2х1,5ок(N)-0,66 5,5 8,1 89
2х2,5ок(N)-0,66 5,8 8,9 114
2х4ок(N)-0,66 6,5 10,2 159
2х6ок(N)-0,66 7 11,2 204
2х10ок(N)-0,66 8,2 13,6 311
2х16ок(N)-0,66 9,3 15,6 443
3х1,5ок(N,PE)-0,66 5,5 10,8 125
3х2,5ок(N,PE)-0,66 5,8 11,9 163
3х4ок(N,PE)-0,66 6,5 13,9 229
3х6ок(N,PE)-0,66 7 15,4 297
3х10ок(N,PE)-0,66 8,2 19 459
3х16ок(N,PE)-0,66 9,3 21,9 656
2х1,5ок(N)-1 5,9 8,9 101
2х2,5ок(N)-1 6,2 9,7 127
2х4ок(N)-1 7,1 11,4 181
2х6ок(N)-1 7,6 12,4 228
2х10ок(N)-1 8,4 14 320
2х16ок(N)-1 9,5 16 454
3х1,5ок(N,PE)-1 5,6 12 144
3х2,5ок(N,PE)-1 6,2 13,1 182
3х4ок(N,PE)-1 7,1 15,7 263
3х6ок(N,PE)-1 7,6 17,2 334
3х10ок(N,PE)-1 8,4 19,6 473
3х16ок(N,PE)-1 9,5 22,5 672