Products

Search by features


АВВГ (AVVG)

АВВГ (AVVG)
Price on request
₽0
By category
Force cables
Voltage
6000
In execution
For a single pad
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVG
Cables with circular conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
1x16/16 19,9 523
1x25/16. 21,2 579
1x35/16 22,2 635
1x50/16 23,4 713
1x70/16 24,9 807
1x95/16 26,6 918
1x120/16 27,9 1026
1x150/25 30 1232
1x185/25 31,8 1375
1x240/25 33,9 1586
1x300/25 36,2 1809
1x400/35 39,3 2254
1x500/35 42 2604
1x630/35 45,8 3087
1x800/35 49,5 3658
3x16/16 34,9 1397
3x25/16 37,8 1516
3x35/16 40 1730
3x50/16 42,9 2025
3x70/16 46,9 2435
3x95/16 50,4 2864
3x120/16 53,3 3309
3x150/25 56,9 3827
3x185/25 60,7 4366
3x240/25 65,4 5217

AVVG
Cables with sector-shaped conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 36,9 1269
3x50/16 39,3 1470
3x70/16 41,7 1716
3x95/16 44,3 2006
3x120/16 47,4 2335
3x150/25 49,9 2746
3x185/25 52,8 3131
3x240/25 57,3 3770

 

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 6 kV of frequency 50 Hz for networks with the earthed and insulated neutral.

The climate modification УХЛ, categories of location 1 and 5 according to GOST 15150, including installation in the ground.

The class of fire hazard of the cables according to GOST 31565 01.8.2.5.4

STRUCTURE

Conductor

Aluminum, single-wire or multi-wire core, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

Is made of PVC-compound (color coded conductor)

Core arrangement

Insulated conductors of multi-core cables are twisted in a cable core.

Inner sheath

It is made by extrusion with PVC-compound or chalk-filled non-cured rubber with the filling of outer gaps between insulated conductors. It is possible to fill the outer gaps between circular insulated cores with the bundles of non hygroscopic fiber or polymer materials with the lapping of fastening tape, on the top of which the extrusion inner sheath is laid. It is allowed to wrap the cable core with the layer of tapes of polymer material. It is allowed the sheathing of double-layer inner extrusion sheath.

Taping

It is made of tape or tapes of conductive paper or conductive synthetic tape or of tapes of non-woven fabric.

Screen

Is made of copper wires and a spirally imposed copper tape. It is allowed the taping of the screen with copper tapes.

Separating layer

Of polymer tape or non-woven fabric.

Over sheath

Of PVC-compound

By category
Force cables
Voltage
6000
In execution
For a single pad
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVG
Cables with circular conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
1x16/16 19,9 523
1x25/16. 21,2 579
1x35/16 22,2 635
1x50/16 23,4 713
1x70/16 24,9 807
1x95/16 26,6 918
1x120/16 27,9 1026
1x150/25 30 1232
1x185/25 31,8 1375
1x240/25 33,9 1586
1x300/25 36,2 1809
1x400/35 39,3 2254
1x500/35 42 2604
1x630/35 45,8 3087
1x800/35 49,5 3658
3x16/16 34,9 1397
3x25/16 37,8 1516
3x35/16 40 1730
3x50/16 42,9 2025
3x70/16 46,9 2435
3x95/16 50,4 2864
3x120/16 53,3 3309
3x150/25 56,9 3827
3x185/25 60,7 4366
3x240/25 65,4 5217

AVVG
Cables with sector-shaped conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 36,9 1269
3x50/16 39,3 1470
3x70/16 41,7 1716
3x95/16 44,3 2006
3x120/16 47,4 2335
3x150/25 49,9 2746
3x185/25 52,8 3131
3x240/25 57,3 3770