Products

Search by features


AВВГгнг(А) (AVVGgng(A))

AВВГгнг(А) (AVVGgng(A))
Price on request
₽0
By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А))
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVGgng(A)
Cables with circular conductors
with aluminum conductor

Number and nom. Cross-section of CCC and screens, nxmm2

External diameter, mm Weight of 1km of cable, kg
1x16/16 20 528
1x25/16. 21,3 584
1x35/16 22,4 641
1x50/16 23,5 719
1x70/16 25 813
1x95/16 26,8 924
1x120/16 28 1034
1x150/25 30,1 1240
1x185/25 31,9 1382
1x240/25 34,1 1593
1x300/25 36,3 1815
1x400/35 39,4 2260
1x500/35 42,1 2611
1x630/35 45,9 3094
1x800/35 49,6 3667
AVVGgng(A)
Cables with circular conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x16/16 35 1402
3x25/16 37,9 1524
3x35/16 40,1 1733
3x50/16 43,1 2035
3x70/16 47 2440
3x95/16 50,5 2871
3x120/16 53,4 3316
3x150/25 57,1 3835
3x185/25 60,8 4374
3x240/25 65,5 5221
AVVGgng(A)
Cables with sector-shaped conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 37,1 1273
3x50/16 39,2 1475
3x70/16 41,9 1721
3x95/16 44,5 2010
3x120/16 47,5 2339
3x150/25 50 2750
3x185/25 52,9 3136
3x240/25 57,4 3774

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 6kV of frequency 50 Hz for networks with the earthed and insulated neutral.

The climate modification УХЛ, categories of location 1 and 5 according to GOST 15150, including installation in the ground.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.5.4.

STRUCTURE

Conductor

Aluminum, single-wire or multi-wire, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

Is made of PVC-compound (color coded conductor).

Core arrangement

Insulated conductors of multi-core cables are twisted in a cable core.

Inner sheath

It is made by extrusion with PVC-compound of low flammability or chalk-filled non-cured rubber with the filling of outer gaps between insulated conductors. It is possible to fill the outer gaps between circular insulated cores with the bundles of with the lapping of fastening tape and extrusion inner sheath. It is allowed to wrap the cable core with the tapes of polymer material.

Taping

In waterproof cables – a layer of water blocking tapes.

Screen

Of copper wires and a spirally imposed copper tape. It is allowed the application of the screen with copper tapes.

Separating layer

In waterproof cables – a layer of water blocking tapes.

Over sheath

Of PVC-compound of low flammability.

By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А))
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVGgng(A)
Cables with circular conductors
with aluminum conductor

Number and nom. Cross-section of CCC and screens, nxmm2

External diameter, mm Weight of 1km of cable, kg
1x16/16 20 528
1x25/16. 21,3 584
1x35/16 22,4 641
1x50/16 23,5 719
1x70/16 25 813
1x95/16 26,8 924
1x120/16 28 1034
1x150/25 30,1 1240
1x185/25 31,9 1382
1x240/25 34,1 1593
1x300/25 36,3 1815
1x400/35 39,4 2260
1x500/35 42,1 2611
1x630/35 45,9 3094
1x800/35 49,6 3667
AVVGgng(A)
Cables with circular conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x16/16 35 1402
3x25/16 37,9 1524
3x35/16 40,1 1733
3x50/16 43,1 2035
3x70/16 47 2440
3x95/16 50,5 2871
3x120/16 53,4 3316
3x150/25 57,1 3835
3x185/25 60,8 4374
3x240/25 65,5 5221
AVVGgng(A)
Cables with sector-shaped conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 37,1 1273
3x50/16 39,2 1475
3x70/16 41,9 1721
3x95/16 44,5 2010
3x120/16 47,5 2339
3x150/25 50 2750
3x185/25 52,9 3136
3x240/25 57,4 3774