Products

Search by features


КВВГнг(А)-LS (KVVGng(A)-LS)

КВВГнг(А)-LS (KVVGng(A)-LS)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) KVVGng(A)-LS
Calculated diameter of cable, mm Calculated weight of cable, kg/km
4x1 7,3 88
5x1 8,0 107
7x1 9,2 148
10x1 11,3 203
14x1 12,2 260
19x1 13,5 334
27x1 15,9 456
37x1 17,7 599
52x1 21,1 838
4x1,5 7,9 109
5x1,5 9,2 149
7x1,5 9,9 185
10x1,5 12,2 255
14x1,5 13,2 332
19x1,5 14,6 430
27x1,5 17,3 590
37x1,5 19,7 800
4x2,5 9,4 165
5x2,5 10,2 204
7x2,5 11,0 258
10x2,5 13,8 358
14x2,5 14,9 473
19x2,5 16,5 618
27x2,5 20,1 877
37x2,5 22,4 1163
4x4 11,0 240
5х4 12,0 299
7x4 13,0 383
10x4 16,4 537
4x6 12,2 322
5х6 13,3 399
7x6 14,5 521
10x6 18,8 754

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage 660V of frequency 100 Hz or direct voltage up to 1000V, for group installation with taking into account the volume of combustible load of the cables, in cable structures and premises of indoor electric units including residential and public buildings.

The climate modification УХЛ and T, categories of location 1 and 5 according to GOST 15150.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.2.2.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

PVC-compound of low flammability.

Core arrangement and twisting

From 4 to 127 insulated conductors.

The insulated conductors are twisted; there is a marker pair in each layer. It is allowed digital and color coded marking of the conductors.

Separating layer

PVC-compound of low flammability.

Over sheath

PVC-compound of low fire hazard.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) KVVGng(A)-LS
Calculated diameter of cable, mm Calculated weight of cable, kg/km
4x1 7,3 88
5x1 8,0 107
7x1 9,2 148
10x1 11,3 203
14x1 12,2 260
19x1 13,5 334
27x1 15,9 456
37x1 17,7 599
52x1 21,1 838
4x1,5 7,9 109
5x1,5 9,2 149
7x1,5 9,9 185
10x1,5 12,2 255
14x1,5 13,2 332
19x1,5 14,6 430
27x1,5 17,3 590
37x1,5 19,7 800
4x2,5 9,4 165
5x2,5 10,2 204
7x2,5 11,0 258
10x2,5 13,8 358
14x2,5 14,9 473
19x2,5 16,5 618
27x2,5 20,1 877
37x2,5 22,4 1163
4x4 11,0 240
5х4 12,0 299
7x4 13,0 383
10x4 16,4 537
4x6 12,2 322
5х6 13,3 399
7x6 14,5 521
10x6 18,8 754