Products

Search by features


ВВГ-Пнг(А) (VVG-Png (A))

ВВГ-Пнг(А) (VVG-Png (A))
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А))
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-Png (A)
Number of conductors Calculated dimensions of cable, mm Calculated weight of cable, kg/km
height width
2х1,5ок(N)-0,66 5,5 8,1 79
2х2,5ок(N)-0,66 5,8 8,9 103
2х4ок(N)-0,66 6,5 10,2 144
2х6ок(N)-0,66 7 11,2 188
2х10ок(N)-0,66 8,2 13,6 288
2х16ок(N)-0,66 9,3 15,6 416
3х1,5ок(N,PE)-0,66 5,5 10,8 112
3х2,5ок(N,PE)-0,66 5,8 11,9 147
3х4ок(N,PE)-0,66 6,5 13,9 209
3х6ок(N,PE)-0,66 7 15,4 274
3х10ок(N,PE)-0,66 8,2 19 426
3х16ок(N,PE)-0,66 9,3 21,9 616
2х1,5ок(N)-1 5,9 8,9 89
2х2,5ок(N)-1 6,2 9,7 114
2х4ок(N)-1 7,1 11,4 163
2х6ок(N)-1 7,6 12,4 208
2х10ок(N)-1 8,4 14 296
2х16ок(N)-1 9,5 16 424
3х1,5ок(N,PE)-1 5,9 12 127
3х2,5ок(N,PE)-1 6,2 13,1 163
3х4ок(N,PE)-1 7,1 15,7 237
3х6ок(N,PE)-1 7,6 17,2 304
3х10ок(N,PE)-1 8,4 19,6 437
3х16ок(N,PE)-1 9,5 22,5 629

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary installations on alternating voltage 0,66; and 1 kV, frequency 50 Hz

Used for installation in dry and humid industrial premises.

The cables VVG-Png(A) are not recommended for laying in the ground (trenches). The cables do not spread burning at group laying.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.5.4.

STRUCTURE

Conductor

Copper single-wire of circular form, of the 1 class according to GOST 22483.

Number of conductors

2 or 3

Nominal cross-section of main conductors

1.5 – 16

Insulation

PVC-compound (color coded conductor).

Core arrangement

Insulated conductors laid in parallel in the same flat.

Inner sheath

PVC-compound of low flammability.

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А))
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-Png (A)
Number of conductors Calculated dimensions of cable, mm Calculated weight of cable, kg/km
height width
2х1,5ок(N)-0,66 5,5 8,1 79
2х2,5ок(N)-0,66 5,8 8,9 103
2х4ок(N)-0,66 6,5 10,2 144
2х6ок(N)-0,66 7 11,2 188
2х10ок(N)-0,66 8,2 13,6 288
2х16ок(N)-0,66 9,3 15,6 416
3х1,5ок(N,PE)-0,66 5,5 10,8 112
3х2,5ок(N,PE)-0,66 5,8 11,9 147
3х4ок(N,PE)-0,66 6,5 13,9 209
3х6ок(N,PE)-0,66 7 15,4 274
3х10ок(N,PE)-0,66 8,2 19 426
3х16ок(N,PE)-0,66 9,3 21,9 616
2х1,5ок(N)-1 5,9 8,9 89
2х2,5ок(N)-1 6,2 9,7 114
2х4ок(N)-1 7,1 11,4 163
2х6ок(N)-1 7,6 12,4 208
2х10ок(N)-1 8,4 14 296
2х16ок(N)-1 9,5 16 424
3х1,5ок(N,PE)-1 5,9 12 127
3х2,5ок(N,PE)-1 6,2 13,1 163
3х4ок(N,PE)-1 7,1 15,7 237
3х6ок(N,PE)-1 7,6 17,2 304
3х10ок(N,PE)-1 8,4 19,6 437
3х16ок(N,PE)-1 9,5 22,5 629