Products

Search by features


АВВГнг(А)-ХЛ (AVVGng(A)-KhL)

АВВГнг(А)-ХЛ (AVVGng(A)-KhL)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Cold-resistant (-HL)
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVGng(A)-KhL
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
1х2,5ок-0,66 5,6 40
1х4ок-0,66 6,3 51
1х6ок-0,66 6,8 60
1х10ок-0,66 8 84
1х16ок-0,66 9,1 113
1х25ок-0,66 10,6 158
1х35ок-0,66 11,6 193
1х50ок-0,66 13,1 247
2х2,5ок(N)-0,66 9,7 117
2х4ок(N)-0,66 11 154
2х6ок(N)-0,66 12 182
2х10ок(N)-0,66 14,4 261
2х16ок(N)-0,66 16,2 339
2х25ок(N)-0,66 21,3 580
2х35ок(N)-0,66 23,6 700
2х50ок(N)-0,66 26,6 916
3х2,5ок(N,PE)-0,66 10,1 130
3х4ок(N,PE)-0,66 11,6 171
3х6ок(N,PE)-0,66 12,6 205
3х10ок(N,PE)-0,66 15,2 297
3х16ок(N,PE)-0,66 17,1 390
3х25ок(N,PE)-0,66 22,5 664
3х35ок(N,PE)-0,66 25 831
3х50ок(N,PE)-0,66 28,1 1060
4х2,5ок(N)-0,66 10,9 149
4х4ок(N)-0,66 12,5 199
4х6ок(N)-0,66 13,7 240
4х10ок(N)-0,66 16,6 354
AVVGng(A)-KhL
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х16ок(N)-0,66 18,8 471
4х25ок(N)-0,66 24,9 818
4х35ок(N)-0,66 27,3 998
4х50ок(N)-0,66 30,8 1278
5х2,5ок(N,PE)-0,66 11,8 175
5х4ок(N,PE)-0,66 13,6 237
5х6ок(N,PE)-0,66 14,9 289
5х10ок(N,PE)-0,66 18,2 422
5х16ок(N,PE)-0,66 20,6 562
5х25ок(N,PE)-0,66 27,2 970
5х35ок(N,PE)-0,66 29,8 1194
5х50ок(N,PE)-0,66 34,2 1537
1х2,5ок-1 6 45
1х4ок-1 6,9 60
1х6ок-1 7,4 70
1х10ок-1 8,2 88
1х16ок-1 9,3 117
1х25ок-1 10,8 162
1х35ок-1 11,8 198
1х50ок-1 13,3 253
2х2,5ок(N)-1 10,5 136
2х4ок(N)-1 12,2 185
2х6ок(N)-1 13,2 216
2х10ок(N)-1 14,8 274
2х16ок(N)-1 16,6 354
2х25ок(N)-1 21,7 600
2х35ок(N)-1 24 744
2х50ок(N)-1 27 940

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary electric installations on alternating voltage 0,66 and 1 kV and frequency 50 Hz or for direct voltage of 1 and 1.5 kV correspondingly.

The cables are used for group installation in cable constructions, openair electrical installations (cable overpasses, arcades).

While manufacturing the cables one uses the materials, which allow the cables to be resistant to low temperatures up to – 600C (degrees below zero) are used.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.5.4.

STRUCTURE

Conductor

Aluminum core of circular of sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

PVC-compound (color coded conductor)

Core arrangement and stranding

Insulated conductors of 2, 3, 4, 5 and 6 core cables twisted in cable core.

Inner sheath

PVC-compound or PVC-compound of low flammability is manufactured with the filling of exterior gaps between insolated conductors.

Cable sheath or jacket

PVC-compound of low flammability

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Cold-resistant (-HL)
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVGng(A)-KhL
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
1х2,5ок-0,66 5,6 40
1х4ок-0,66 6,3 51
1х6ок-0,66 6,8 60
1х10ок-0,66 8 84
1х16ок-0,66 9,1 113
1х25ок-0,66 10,6 158
1х35ок-0,66 11,6 193
1х50ок-0,66 13,1 247
2х2,5ок(N)-0,66 9,7 117
2х4ок(N)-0,66 11 154
2х6ок(N)-0,66 12 182
2х10ок(N)-0,66 14,4 261
2х16ок(N)-0,66 16,2 339
2х25ок(N)-0,66 21,3 580
2х35ок(N)-0,66 23,6 700
2х50ок(N)-0,66 26,6 916
3х2,5ок(N,PE)-0,66 10,1 130
3х4ок(N,PE)-0,66 11,6 171
3х6ок(N,PE)-0,66 12,6 205
3х10ок(N,PE)-0,66 15,2 297
3х16ок(N,PE)-0,66 17,1 390
3х25ок(N,PE)-0,66 22,5 664
3х35ок(N,PE)-0,66 25 831
3х50ок(N,PE)-0,66 28,1 1060
4х2,5ок(N)-0,66 10,9 149
4х4ок(N)-0,66 12,5 199
4х6ок(N)-0,66 13,7 240
4х10ок(N)-0,66 16,6 354
AVVGng(A)-KhL
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х16ок(N)-0,66 18,8 471
4х25ок(N)-0,66 24,9 818
4х35ок(N)-0,66 27,3 998
4х50ок(N)-0,66 30,8 1278
5х2,5ок(N,PE)-0,66 11,8 175
5х4ок(N,PE)-0,66 13,6 237
5х6ок(N,PE)-0,66 14,9 289
5х10ок(N,PE)-0,66 18,2 422
5х16ок(N,PE)-0,66 20,6 562
5х25ок(N,PE)-0,66 27,2 970
5х35ок(N,PE)-0,66 29,8 1194
5х50ок(N,PE)-0,66 34,2 1537
1х2,5ок-1 6 45
1х4ок-1 6,9 60
1х6ок-1 7,4 70
1х10ок-1 8,2 88
1х16ок-1 9,3 117
1х25ок-1 10,8 162
1х35ок-1 11,8 198
1х50ок-1 13,3 253
2х2,5ок(N)-1 10,5 136
2х4ок(N)-1 12,2 185
2х6ок(N)-1 13,2 216
2х10ок(N)-1 14,8 274
2х16ок(N)-1 16,6 354
2х25ок(N)-1 21,7 600
2х35ок(N)-1 24 744
2х50ок(N)-1 27 940