Products

Search by features


АВВГ-Пнг(А)-LS (AVVG-Png(A)-LS)

АВВГ-Пнг(А)-LS (AVVG-Png(A)-LS)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVG-Png(A)-LS
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated height of cable, mm Calculated width of cable, mm Calculated weight of cable, kg/km
 2х2,5ок(N)-0,66 5,8 8,9 85
2х4ок(N)-0,66 6,5 10,2 111
2х6ок(N)-0,66 7,0 11,2 133
2х10ок(N)-0,66 8,2 13,6 192
2х16ок(N)-0,66 9,3 15,6 255
2х2,5ок(N)-1 6,2 9,7 98
2х4ок(N)-1 7,1 11,4 133
2х6ок(N)-1 7,6 12,4 157
2х10ок(N)-1 8,4 14,0 201
2х16ок(N)-1 9,5 16,0 266
3х2,5ок(N,PE)-0,66 5,8 11,9 119
3х4ок(N,PE)-0,66 6,5 13,9 158
3х6ок(N,PE)-0,66 7,0 15,4 191
3х10ок(N,PE)-0,66 8,2 19,0 280
3х16ок(N,PE)-0,66 9,3 21,9 374
3х2,5ок(N,PE)-1 6,2 13,1 138
3х4ок(N,PE)-1 7,1 15,7 191
3х6ок(N,PE)-1 7,6 17,2 228
3х10ок(N,PE)-1 8,4 19,6 294
3х16ок(N,PE)-1 9,5 22,5 390

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cable AVVG-Png(A)-LS is designed for transmission and distribution of electric energy in stationary electric installations on alternating voltage 0,66 and 1kV and frequency 50 Hz.

The cables are used for electrical installations in residential and public buildings.

The cables are designed for use in cable structures and premises, including the objects where nuclear energy is used in the AC systems of classes 3 and 4 according to classification ОПБ-88 (ПНАЭГ–01-011-97).

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.2.2.

STRUCTURE

Conductor

Aluminum, single-wire, of circular form, of the 1 class according to GOST 22483.

Number of conductors

2 or 3

Nominal cross-section of the conductors, mm2

2.5-16

Insulation

PVC-compound of low flammability (color coded conductor).

Core arrangement

Insulated conductors laid in parallel in one flat.

Cable sheath

PVC-compound of low flammability

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVVG-Png(A)-LS
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated height of cable, mm Calculated width of cable, mm Calculated weight of cable, kg/km
 2х2,5ок(N)-0,66 5,8 8,9 85
2х4ок(N)-0,66 6,5 10,2 111
2х6ок(N)-0,66 7,0 11,2 133
2х10ок(N)-0,66 8,2 13,6 192
2х16ок(N)-0,66 9,3 15,6 255
2х2,5ок(N)-1 6,2 9,7 98
2х4ок(N)-1 7,1 11,4 133
2х6ок(N)-1 7,6 12,4 157
2х10ок(N)-1 8,4 14,0 201
2х16ок(N)-1 9,5 16,0 266
3х2,5ок(N,PE)-0,66 5,8 11,9 119
3х4ок(N,PE)-0,66 6,5 13,9 158
3х6ок(N,PE)-0,66 7,0 15,4 191
3х10ок(N,PE)-0,66 8,2 19,0 280
3х16ок(N,PE)-0,66 9,3 21,9 374
3х2,5ок(N,PE)-1 6,2 13,1 138
3х4ок(N,PE)-1 7,1 15,7 191
3х6ок(N,PE)-1 7,6 17,2 228
3х10ок(N,PE)-1 8,4 19,6 294
3х16ок(N,PE)-1 9,5 22,5 390