Products

Search by features


КPSVVng(А)-LS, КPSVVGng(А)-LS, КPSVEVng(А)-LS, КPSVEVGng(А)-LS, КPSVEEVng(А)-LS, КPSVEEVGng(А)-LS, according to specifications 16.K121-020-2011
specifications 16.K121-020-2011

Current-carrying conductor

Copper, single-wire of the 1 class or multi-wire not less than of the 3 class according to GOST 22483, with the cross-sections from 0.2 to 2.5 mm2.

Insulation

PVC-compound of low fire hazard (color-coded conductors).

Core arrangement and twisting

Insulated conductors are twisted in a pair.

Screen

Alum polymer tape with a contact conductor of copper, galvanized wire is lapped in the way of winding or longitudinally by overlapping;

-over the twisted pairs of cables KPSVЕVng(A)- LS and KPSVЕVGng(A)-LS;

- over each pair individually in two-pair cables KPSVЕEVng(A)-LS and KPSVЕEVGng(A)-LS

Over sheath

PVC-compound of low fire hazard.

The cables are designed for installation of fire and security alarm systems, systems of access control and other management systems, control and communications in the conditions of stationary laying inside of buildings and structures if it is necessary to protect the electric circuits from the influence of external electric fields.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.2.2

Nominal voltage, not more than, V 300
Ambient temperature during cable operation, °С from – 50 to + 70
The ambient temperature for laying and installation of the cables (without preheat) is made, 0C not below - 15
Minimum bending radius, diameters of the cable - with the single wire cores not less 10
-with the multi-wire cores not less 6
Service life, not less 15 years
Smoke generation in the test cell not more than 50%

Table 1

Electric parameters

Name of parameter on frequency 0.8 kHz Type of cable Value for rated cross-section of conductors, mm2
0,2 0,35 0,5 0,75 1 1,5 2,5
Electric capacity, converted on 1 km, nF, not more КPSVVng(А)-LS, КPSVVGng(А)-LS 65 70 75 80 90 100 110
КPSVEVng(А)-LS, КPSVEVGng(А)-LS, КPSVEEVng(А)-LS, КPSVEEVGng(А)-LS 70 95 108 116 118 123 138
Attenuation coefficient converted on 1 km of length, dB, not more КPSVVng(А)-LS, КPSVVGng(А)-LS 1,8 1,45 1,33 1,06 0,93 0,68 0,58
КPSVEVng(А)-LS, КPSVEVGng(А)-LS, КPSVEEVng(А)-LS, КPSVEEVGng(А)-LS 2,05 1,6 1,34 1,11 0,94 0,79 0,64

 