РВГ-Пнг(А)-FRLS (RVG-Рng(A)-FRLS)

РВГ-Пнг(А)-FRLS (RVG-Рng(A)-FRLS)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR)
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
 width  height
2х1,5ок(N)-0,66  7,9 5,1 72
2х2,5ок(N)-0,66  8,7 5,4 95
2х4ок(N)-0,66  10 6,1 134
2х6ок(N)-0,66  11 6,6 175
3х1,5ок(N,PE)-0,66  10,8 5,1 102
3х2,5ок(N,PE)-0,66  11,9 5,4 135
3х4ок(N,PE)-0,66  13,9 6,1 193
3х6ок(N,PE)-0,66  15,4 6,6 255
2х1,5ок(N)-1  8,7 5,5 81
2х2,5ок(N)-1 9,5 5,8 104
2х4ок(N)-1  10,8 6,5 144
2х6ок(N)-1  11,8 7,0 187
3х1,5ок(N,PE)-1  12,0 5,5 145
3х2,5ок(N,PE)-1  13,1 5,8 149
3х4ок(N,PE)-1  15,1 6,5 209
3х6ок(N,PE)-1 16,6 7,0 272

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power in stationary installations on the nominal alternating voltage to 0.66 and 1kV and frequency 50 Hz. The cables do not spread combustion at group stationary installation of cable lines, in the absence of mechanical effects and keep working when exposed to flame not less than 180 minutes.

They are designed for wiring and networks of the wiring circuits of emergency power supply of the equipment (current collectors), in residential and public buildings, in the surgical departments of hospitals, in office premises, equipped with computer and microprocessor devices, entertainment complexes and sports facilities, as well as at other objects with the high demand of fire safety.

The class of fire hazard of the cables according to GOST 31565 for cables П1б.1.2.2.2.

STRUCTURE

Number of conductors

2 or 3.

Conductor

Copper, of circular form, single-wire core, with the cross-section from 1.5 to 16mm2 or multiwire core with the cross-section from 10 to 16mm2

Insulation

Ceramics-forming rubber.

Core arrangement and twisting

For RVG-Рng(A)-FRLS insulated cores situated in parallel in one flat.

Over sheath

PVC-compound of low fire hazard.

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR)
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
 width  height
2х1,5ок(N)-0,66  7,9 5,1 72
2х2,5ок(N)-0,66  8,7 5,4 95
2х4ок(N)-0,66  10 6,1 134
2х6ок(N)-0,66  11 6,6 175
3х1,5ок(N,PE)-0,66  10,8 5,1 102
3х2,5ок(N,PE)-0,66  11,9 5,4 135
3х4ок(N,PE)-0,66  13,9 6,1 193
3х6ок(N,PE)-0,66  15,4 6,6 255
2х1,5ок(N)-1  8,7 5,5 81
2х2,5ок(N)-1 9,5 5,8 104
2х4ок(N)-1  10,8 6,5 144
2х6ок(N)-1  11,8 7,0 187
3х1,5ок(N,PE)-1  12,0 5,5 145
3х2,5ок(N,PE)-1  13,1 5,8 149
3х4ок(N,PE)-1  15,1 6,5 209
3х6ок(N,PE)-1 16,6 7,0 272