Products

Search by features


КППГнг(А)-HF (KPPGng(A)-HF)

КППГнг(А)-HF (KPPGng(A)-HF)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF)
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGng(A)-HF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х0,75 7,0 74
5х0,75 7,5 90
7х0,75 8,1 111
10х0,75 10,7 169
14х0,75 11,5 216
19х0,75 12,7 276
27х0,75 15,0 375
37х0,75 16,7 491
52х0,75 19,9 686
4х1,0 7,3 86
5х1,0 8,0 105
7х1,0 9,2 145
10х1,0 11,3 199
14х1,0 12,2 257
19х1,0 13,5 330
27х1,0 15,9 451
37х1,0 17,7 594
52х1,0 21,1 831
4х1,5 7,9 107
5х1,5 9,2 146
7х1,5 9,9 182
10х1,5 12,2 252
14х1,5 13,2 328
19х1,5 14,6 425
27х1,5 17,3 585
37х1,5 19,7 794
4х2,5 9,4 163
5х2,5 10,2 200
7х2,5 11,0 254
10х2,5 13,8 354
14х2,5 14,9 469
19х2,5 16,5 614
27х2,5 20,1 870
37х2,5 22,4 1156
4х4 11,0 237
5х4 12,0 295
7х4 13,0 379
10х4 16,4 532
4х6 12,2 318
5х6 13,3 395
7х6 14,5 516
10х6 18,8 747

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage 660V of frequency 100 Hz or direct voltage up to 1000V.

The cables are used at group installation of cable lines of power and control circuits. The cables are designed for large thermal power stations, petrochemical objects, in the subway, in buildings and structures with mass stay of people, concert halls and indoor stadiums, theatres, airports and railway stations; in premises, equipped with computer and microprocessor appliances and other objects which have increased requirements for fire safety.

The class of fire hazard of the cables according to GOST 31565 of cables of modification "ng(A)-HF"- П1б.8.1.2.1.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

Halogen-free polymer composition.

Core arrangement

From 4 to 127 insulated conductors.

The insulated conductors are twisted; there is a marker pair in each layer. It is allowed digital and color coded marking of the conductors.

Separating layer

Halogen-free polymer composition.

Over sheath or jacket

Halogen-free polymer composition.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF)
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGng(A)-HF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х0,75 7,0 74
5х0,75 7,5 90
7х0,75 8,1 111
10х0,75 10,7 169
14х0,75 11,5 216
19х0,75 12,7 276
27х0,75 15,0 375
37х0,75 16,7 491
52х0,75 19,9 686
4х1,0 7,3 86
5х1,0 8,0 105
7х1,0 9,2 145
10х1,0 11,3 199
14х1,0 12,2 257
19х1,0 13,5 330
27х1,0 15,9 451
37х1,0 17,7 594
52х1,0 21,1 831
4х1,5 7,9 107
5х1,5 9,2 146
7х1,5 9,9 182
10х1,5 12,2 252
14х1,5 13,2 328
19х1,5 14,6 425
27х1,5 17,3 585
37х1,5 19,7 794
4х2,5 9,4 163
5х2,5 10,2 200
7х2,5 11,0 254
10х2,5 13,8 354
14х2,5 14,9 469
19х2,5 16,5 614
27х2,5 20,1 870
37х2,5 22,4 1156
4х4 11,0 237
5х4 12,0 295
7х4 13,0 379
10х4 16,4 532
4х6 12,2 318
5х6 13,3 395
7х6 14,5 516
10х6 18,8 747