Products

Search by features


ПвБПнг(А)- FRHF- (PvBPng(A)- FRHF)

ПвБПнг(А)- FRHF- (PvBPng(A)- FRHF)
Price on request
₽0
By category
Force cables
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
PvBPng(A)-FRHF 0,66 кV
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
3х1,5-0,66 14,8 394
3х2,5-0,66 15,6 457
3х4-0,66 16,6 541
3х6-0,66 17,7 642
3х10-0,66 19,5 828
3х16-0,66  21,5 1085
3х25-0,66  26,7 1629
3х35-0,66  29,4 2056
3х50-0,66  28,7 2826
4х1,5-0,66 15,7 439
4х2,5-0,66 16,7 515
4х4-0,66 17,8 617
4х6-0,66 19,1 741
4х10-0,66 21 969
4х16-0,66  23,3 1288
4х25-0,66  29,3 1958
4х35-0,66  32 2472
4х50-0,66  31,7 3531
5х1,5-0,66 16,8 483
5х2,5-0,66 17,9 570
5х4-0,66 19,2 688
5х6-0,66 20,5 832
5х10-0,66 22,7 1100
5х16-0,66 25,7 1502
5х25-0,66  31,9 2241
5х35 -0,66 35,6 2906
5х50-0,66 35,4 4296

PvBPng(A)-FRHF 3кV
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
1х240-3 36,4 3365
1х300-3 38,7 4008
1х400-3 42,1 5076
1х500-3 46,5 6407
1х630-3 51,1 7913

 

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary electric installations, for installation in cable structures, buildings and underground structures, including flammable and explosive areas, for supply chains of the equipment, which operates in fire.

The cables of types PvPGEng(A)-FRHF and PvBPng(A)-FRHF of rated voltage 3 kV are used in DC voltage units and they are available in single-core modification.

The class of fire hazard of the cables according to GOST 31565-2012 П1б.1.1.2.1.

 

TECHNICAL DATA

Nominal voltage, kV – 0.66, 1 or 3

Ambient temperature during cable operation, °С: - from -50 to +50

Resistant with a relative humidity up to 98% at ambient temperature, degree Celsius: +35

Minimum bending radius, diameters of cable:

for single-wire – 10

or multi-wire – 7,5

Service life, years, not less: 40

Smoke generation in the test cell: not more than 40 %

Flame retardance test category at group installation: А

Equivalent toxicity index, g/m3 , more than : 40

Fire resistance of the cable, minutes, not less than: 180

 

STRUCTURE

Conductor

Copper, single-wire or multi-wire of the 1st or 2nd classes according to GOST 22483-2012, of the cross-section for 0.66 kV – 1.5 – 50 mm2;

for 1 kV – 1.5 – 240 mm2, single-wire – 50-630 мм2;

for 3 kV – 240 – 630 mm2.

Thermal barrier

The lapping with mica tapes.

Insulation

Cross-linked, halogen free polymer composition.

Screen for single-wire cables of nominal voltage 3kV:

It is made of copper tapes or copper wires and a copper tape overlaid spirally.

Core arrangement

Insulated conductors of multi-core cables on 0.66 and 1kV are twisted in a cable core.

The cables have got distinctive markings of insulated cores: color or digital.

Inner sheath or separating layer (for armored cables on voltage 3kV)

It is made by extrusion with filling with the halogen free polymer compositions.

Cable armoring

For cables of types PvBShvng(A)-FRHF is laid helically with two steel, galvanized tapes.

It is possible to lay the PET-tapes by winding or longitudinally over the armor.

Cable sheath or jacket

Halogen free polymer composition.

By category
Force cables
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
PvBPng(A)-FRHF 0,66 кV
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
3х1,5-0,66 14,8 394
3х2,5-0,66 15,6 457
3х4-0,66 16,6 541
3х6-0,66 17,7 642
3х10-0,66 19,5 828
3х16-0,66  21,5 1085
3х25-0,66  26,7 1629
3х35-0,66  29,4 2056
3х50-0,66  28,7 2826
4х1,5-0,66 15,7 439
4х2,5-0,66 16,7 515
4х4-0,66 17,8 617
4х6-0,66 19,1 741
4х10-0,66 21 969
4х16-0,66  23,3 1288
4х25-0,66  29,3 1958
4х35-0,66  32 2472
4х50-0,66  31,7 3531
5х1,5-0,66 16,8 483
5х2,5-0,66 17,9 570
5х4-0,66 19,2 688
5х6-0,66 20,5 832
5х10-0,66 22,7 1100
5х16-0,66 25,7 1502
5х25-0,66  31,9 2241
5х35 -0,66 35,6 2906
5х50-0,66 35,4 4296

PvBPng(A)-FRHF 3кV
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
1х240-3 36,4 3365
1х300-3 38,7 4008
1х400-3 42,1 5076
1х500-3 46,5 6407
1х630-3 51,1 7913