Products

Search by features


AВБВнг(А) (AVBVng(A))

AВБВнг(А) (AVBVng(A))
Price on request
₽0
By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А)) / Armored
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVBVng(A)
Cables with circular conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x16/16 38,7 2078
3x25/16 41,6 2362
3x35/16 43,9 2627
3x50/16 47,1 3032
3x70/16 50,8 3487
3x95/16 54,2 3993
3x120/16 57,6 4561
3x150/25 60,8 5106
3x185/25 64,5 5731
3x240/25 70,4 6895
AVBVng(A)
Cables with sector-shaped conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 40,8 2097
3x50/16 43,1 2349
3x70/16 45,9 2695
3x95/16 48,5 3045
3x120/16 51,2 3398
3x150/25 53,8 3867
3x185/25 57 4370
3x240/25 61,2 5060

 

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 6kV of frequency 50 Hz for networks with the earthed and insulated neutral.

They can be laid in dry soils (sand, sandy-clay and normal soil with a moisture content of 14%). The cables can be laid in the explosive areas of classes B-1б, В-1г, В-II, B-IIa.

The climate modification УХЛ, categories of location 1 and 5 according to GOST 15150, including installation in the ground.

The class of fire hazard of the cables according to GOST 31565 01.8.2.5.4.

STRUCTURE

Conductor

Aluminum, single-wire or multi-wire, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

Is made of PVC-compound (color coded conductor).

Inner sheath

It is made by extrusion with PVC-compound of low flammability or chalk-filled non-cured rubber with the filling of outer gaps between insulated conductors. It is possible to fill the outer gaps between circular insulated cores with the bundles of non hygroscopic fiber or polymer materials with the lapping of fastening tape, on the top of which the extrusion inner sheath is laid. It is allowed to wrap the cable core with the layer of tapes of polymer material, compatible with the materials of insulation and over sheath.

Taping

Is made of tape or tapes of conductive paper or conductive synthetic tape, or tapes of non-woven conductive fabric.

Screen

Of copper wires and a spirally imposed copper tape. It is allowed the application of the screen with copper tapes.

Separating layer

Of polymer tape or non-woven fabric.

Bedding

Of PVC-compound of low flammability.

Cable armoring

It is lapped helically with two steel, galvanized tapes. It is possible to overlap or wrap longitudinally with PET or polypropylene tape.

Over sheath

Of PVC-compound of low flammability.

By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А)) / Armored
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVBVng(A)
Cables with circular conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x16/16 38,7 2078
3x25/16 41,6 2362
3x35/16 43,9 2627
3x50/16 47,1 3032
3x70/16 50,8 3487
3x95/16 54,2 3993
3x120/16 57,6 4561
3x150/25 60,8 5106
3x185/25 64,5 5731
3x240/25 70,4 6895
AVBVng(A)
Cables with sector-shaped conductors
with aluminum conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 40,8 2097
3x50/16 43,1 2349
3x70/16 45,9 2695
3x95/16 48,5 3045
3x120/16 51,2 3398
3x150/25 53,8 3867
3x185/25 57 4370
3x240/25 61,2 5060