Products

Search by features


РВГ-Пнг(А)-FRLSTx (RVG-Png(A)-FRLSTx)

РВГ-Пнг(А)-FRLSTx (RVG-Png(A)-FRLSTx)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Low toxicity (-LTx) / Fireproof (-FR)
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
 width  height
2х1,5ок(N)-0,66 7,9 5,1 74
2х2,5ок(N)-0,66 8,7 5,4 97
2х4ок(N)-0,66 10,0 6,1 137
2х6ок(N)-0,66 11,0 6,6 179
3х1,5ок(N,PE)-0,66 10,8 5,1 105
3х2,5ок(N,PE)-0,66 11,9 5,4 138
3х4ок(N,PE)-0,66 13,9 6,1 197
3х6ок(N,PE)-0,66 15,4 6,6 260
2х1,5ок(N)-1 8,7 5,5 84
2х2,5ок(N)-1 9,5 5,8 107
2х4ок(N)-1 10,8 6,5 148
2х6ок(N)-1 11,8 7,0 190
3х1,5ок(N,PE)-1 12,0 5,5 118
3х2,5ок(N,PE)-1 13,1 5,8 153
3х4ок(N,PE)-1 15,1 6,5 213
3х6ок(N,PE)-1 16,6 7,0 277

 

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power in stationary installations on the nominal alternating voltage to 0.66 and 1kV and frequency 50 Hz. The cables do not spread combustion at group installation of cable lines in the absence of mechanical effects on the cable and keep working when exposed by flame on the cable not less than 180 minutes.

The cables are designed for wiring and emergency power circuits of equipment (current collectors), in residential and public buildings, in the surgical departments of hospitals, in the office premises, equipped with computer and micro processor devices, spectacular complexes and sports facilities, as well as in other objects with the high demand of fire safety.

The class of fire hazard of the cables according to GOST 31565 П1б.1.2.1.2.

STRUCTURE

Conductor

Copper of round form, single-wire with the cross-section from 1.5 to 16 mm2 of the 1 class or multi-wire core with the cross-section from 10 to 16 mm2 of the 2 class according to GOST 22483.

Insulation

Ceramic forming silicone rubber.

Core arrangement

Insulated conductors of 2 and 3 core cables of types RVG-Png(A)-FRLSTx are arranged in parallel in one flat.

Inner sheath

PVC-compound of low toxicity.

Over sheath

PVC-compound of low toxicity

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Low toxicity (-LTx) / Fireproof (-FR)
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
 width  height
2х1,5ок(N)-0,66 7,9 5,1 74
2х2,5ок(N)-0,66 8,7 5,4 97
2х4ок(N)-0,66 10,0 6,1 137
2х6ок(N)-0,66 11,0 6,6 179
3х1,5ок(N,PE)-0,66 10,8 5,1 105
3х2,5ок(N,PE)-0,66 11,9 5,4 138
3х4ок(N,PE)-0,66 13,9 6,1 197
3х6ок(N,PE)-0,66 15,4 6,6 260
2х1,5ок(N)-1 8,7 5,5 84
2х2,5ок(N)-1 9,5 5,8 107
2х4ок(N)-1 10,8 6,5 148
2х6ок(N)-1 11,8 7,0 190
3х1,5ок(N,PE)-1 12,0 5,5 118
3х2,5ок(N,PE)-1 13,1 5,8 153
3х4ок(N,PE)-1 15,1 6,5 213
3х6ок(N,PE)-1 16,6 7,0 277