Products

Search by features


КПСЭГнг(А)-FRLS (KPSEGng(A)-FRLS)

КПСЭГнг(А)-FRLS (KPSEGng(A)-FRLS)
Price on request
₽0
By category
Cables for fire alarm systems
Voltage
300
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR) / Shielded
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPSEGng(A)-FRLS
Number of pairs in cable, pcs Cross-section, mm2 External dimensions or diameter of cable, mm Calculated weight of 1km of cable, kg/km
1 0,2 5,1 27
2 4,7х8,2 42
1 0,35 5,7 34
2 5,3х9,3 55
1 0,5 6,2 39
2 5,8х10,4 65
1 0,75 6,7 47
2 6,3х11,4 79
1 1 7,2 55
2 6,8х12,3 94
1 1,5 7,9 67
2 7,5х13,8 119
1 2,5 9 93
2 8,6х16,1 169

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for single or group stationary laying in fire protection systems, fire alarm systems in warning systems and evacuation management of people during fire, in buildings, constructions and structures ( industrial enterprises, schools, hospitals, office premises, high-rise buildings, subways and nuclear power plants) where requirements for cables and wires to survive in fire conditions exist.

The cables keep working in fire conditions for a period of 180 minutes.

They are operated inside and outside the premises, provided protection from direct affect of solar radiation and precipitation.

The class of fire hazard of the cables according to GOST 31565 П1б.1.2.2.2.

STRUCTURE

Current-carrying conductor

Copper, multi-wire not less than of the 3 class according to GOST 22483, with the cross-sections from 0.2 to 2.5 mm2.

Insulation

Silicon organic rubber (color-coded conductors).

Core arrangement and twisting

Insulated conductors are twisted in a pair. The twisted pairs are situated in parallel in cables with two pairs.

Screen

Alum polymer tape with a contact conductor of copper, galvanized wire is lapped in the way of winding or longitudinally by overlapping over the twisted pairs of cables

Over sheath

PVC-compound of low fire hazard

By category
Cables for fire alarm systems
Voltage
300
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR) / Shielded
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPSEGng(A)-FRLS
Number of pairs in cable, pcs Cross-section, mm2 External dimensions or diameter of cable, mm Calculated weight of 1km of cable, kg/km
1 0,2 5,1 27
2 4,7х8,2 42
1 0,35 5,7 34
2 5,3х9,3 55
1 0,5 6,2 39
2 5,8х10,4 65
1 0,75 6,7 47
2 6,3х11,4 79
1 1 7,2 55
2 6,8х12,3 94
1 1,5 7,9 67
2 7,5х13,8 119
1 2,5 9 93
2 8,6х16,1 169