КВВГнг(А)-FRLS (KVVGng(A)-FRLS)

КВВГнг(А)-FRLS (KVVGng(A)-FRLS)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х0,75 11,2 236
5х0,75 12,1 270
7х0,75 13,1 324
10х0,75 16,4 443
14х0,75 17,8 536
19х0,75 20,1 684
27х0,75 24,3 934
37х0,75 27,1 1173
52х0,75 31,8 1547
61х0,75 33,7 1753
4х1,0 11,6 257
5х1,0 12,6 294
7х1,0 13,6 355
10х1,0 17,0 488
14х1,0 18,8 614
19х1,0 20,9 758
27х1,0 25,2 1038
37х1,0 28,2 1311
52х1,0 33,0 1736
61х1,0 35,5 2012
4х1,5 12,2 294
5х1,5 13,2 339
7х1,5 14,3 412
10х1,5 18,4 590
14х1,5 20,0 721
19х1,5 22,2 898
27х1,5 26,8 1234
37х1,5 30,0 1570
52х1,5 35,6 2132
61х1,5 37,8 2426
4х2,5 13,1 361
5х2,5 14,3 419
7х2,5 15,6 517
10х2,5 20,1 741
14х2,5 21,7 919
19х2,5 24,6 1184
27х2,5 29,3 1596
37х2,5 32,8 2050
52х2,5 39,0 2798
4х4 14,8 475
7х4 17,6 695
10х4 22,7 996
4х6 16,0 591
7х6 19,5 901
10х6 25,2 1289

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz or direct voltage up to 1000V, for group installation with taking into account the volume of combustible load of the cables in the fire protection systems and other systems that must remain operational in case of fire within 180 minutes.

The cables are manufactured for general industrial use and use in nuclear power stations (NPP) outside the hermetical unit in the system as class 2 according to the classification ОПБ 88/97 (ПНАЭ Г-01-11)

The class of fire hazard of the cables according to GOST 31565 П1б.1.2.2.2.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Thermal barrier

The lapping with two mica tapes.

Insulation

PVC-compound of low fire hazard.

Core arrangement

Number of conductors from 4 to 61.

The insulated conductors are twisted in the cable core, the conductors are color-coded, which provide the identification of each core during installation.

Color-coded is solid or in the form of longitudinal strips of a width not less than 1mm.

Over sheath

PVC-compound of low fire hazard.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х0,75 11,2 236
5х0,75 12,1 270
7х0,75 13,1 324
10х0,75 16,4 443
14х0,75 17,8 536
19х0,75 20,1 684
27х0,75 24,3 934
37х0,75 27,1 1173
52х0,75 31,8 1547
61х0,75 33,7 1753
4х1,0 11,6 257
5х1,0 12,6 294
7х1,0 13,6 355
10х1,0 17,0 488
14х1,0 18,8 614
19х1,0 20,9 758
27х1,0 25,2 1038
37х1,0 28,2 1311
52х1,0 33,0 1736
61х1,0 35,5 2012
4х1,5 12,2 294
5х1,5 13,2 339
7х1,5 14,3 412
10х1,5 18,4 590
14х1,5 20,0 721
19х1,5 22,2 898
27х1,5 26,8 1234
37х1,5 30,0 1570
52х1,5 35,6 2132
61х1,5 37,8 2426
4х2,5 13,1 361
5х2,5 14,3 419
7х2,5 15,6 517
10х2,5 20,1 741
14х2,5 21,7 919
19х2,5 24,6 1184
27х2,5 29,3 1596
37х2,5 32,8 2050
52х2,5 39,0 2798
4х4 14,8 475
7х4 17,6 695
10х4 22,7 996
4х6 16,0 591
7х6 19,5 901
10х6 25,2 1289