Products

Search by features


КППГЭнг(А)-HF (KPPGЕng(A)-HF)

КППГЭнг(А)-HF (KPPGЕng(A)-HF)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Shielded
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGЕng(A)-HF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 10,7 163
5х1,0 11,4 187
7х1,0 12 219
10х1,0 14,3 296
14х1,0 15,2 360
19х1,0 16,5 443
27х1,0 18,9 583
37х1,0 20,7 738
52х1,0 24,3 1015
4х1,5 11,3 188
5х1,5 12 219
7х1,5 12,7 262
10х1,5 15,3 355
14х1,5 16,2 439
19х1,5 17,6 547
27х1,5 20,3 727
37х1,5 22,3 931
4х2,5 12,2 238
5х2,5 13,2 287
7х2,5 14 349
10х2,5 16,8 469
14х2,5 17,9 592
19х2,5 19,5 749
27х2,5 22,7 1010
37х2,5 25,6 1350
4х4 14 331
7х4 16 489
10х4 19,5 667
4х6 15,2 421
7х6 17,5 637
10х6 21,4 878

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of nominal electric power and electric signals at the stationary installation on the nominal alternating voltage 660 V of nominal frequency up to 100 Hz including for use in NPP systems of class 3H according to classification ОПБ-88/97 (ПНАЭ Г-01-011).

The cables recommended, especially for use at nuclear power stations, large thermal power stations, petrochemical objects, in the subway, on ships; buildings with mass stay of people: concert halls and indoor stadiums, theatres, airports and railway stations; in premises, equipped with computer and microprocessor appliances and other objects which have increased requirements for fire safety.

The class of fire hazard of the cables according to GOST 31565 П1б.8.1.2.1.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 1 to 6 mm2.

Insulation

Halogen-free polymer composition.

Core arrangement

From 4 to 52 insulated conductors.

The insulated conductors of the cables are twisted.

Control cables have distinctive markings of insulated conductors (digital or color).

Inner sheath

Halogen-free polymer composition.

Screen

For cables of types KPPGЕng(A)-HF is made in the form of taping with the foiled flexible alumoflex with the contact conductor with a copper, galvanized wire.

Over sheath or jacket

Of halogen-free polymer composition.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Shielded
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGЕng(A)-HF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 10,7 163
5х1,0 11,4 187
7х1,0 12 219
10х1,0 14,3 296
14х1,0 15,2 360
19х1,0 16,5 443
27х1,0 18,9 583
37х1,0 20,7 738
52х1,0 24,3 1015
4х1,5 11,3 188
5х1,5 12 219
7х1,5 12,7 262
10х1,5 15,3 355
14х1,5 16,2 439
19х1,5 17,6 547
27х1,5 20,3 727
37х1,5 22,3 931
4х2,5 12,2 238
5х2,5 13,2 287
7х2,5 14 349
10х2,5 16,8 469
14х2,5 17,9 592
19х2,5 19,5 749
27х2,5 22,7 1010
37х2,5 25,6 1350
4х4 14 331
7х4 16 489
10х4 19,5 667
4х6 15,2 421
7х6 17,5 637
10х6 21,4 878