КПвБШвнг(А)-FRLS - (KPvBShvng(A)-FRLS)

КПвБШвнг(А)-FRLS - (KPvBShvng(A)-FRLS)
Price on request
₽0
By category
Control cables
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR) / Armored
Insulation
Copper
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPvBShvng(A)-FRLS
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
4х1,5 17,3 1580
5х1,5 18,4 1910
7х1,5 19,5 2552
10х1,5 23,2 651
14х1,5 24,9 730
19х1,5 27,1 820
27х1,5 31,4 1129
37х1,5 34,9 1297
52х1,5 40,1 1529
61х1,5 42,3 2013
4х2,5 18,3 2468
5х2,5 19,5 3223
7х2,5 20,7 3579
10х2,5 25 742
14х2,5 26,7 839
19х2,5 29,1 954
27х2,5 34,2 1345
37х2,5 37,7 1548
4х4 19,4 2499
5х4 20,8 3049
7х4 22,1 4027
10х4 26,9 861
4х6 20,7 982
5х6 22,1 1133
7х6 23,9 1617
10х6 28,9 1005

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary installations, for installation in cable structures, buildings and underground structures, including flammable and explosive areas, as well as for the power circuits of the equipment that operates in the fire.

The class of fire hazard of the cables according to GOST 31565-2012 П1б.1.2.2.2.

 

TECHNICAL DATA

Nominal voltage, kV: 0,66

Ambient temperature during cable operation, °С: from -50 to +50

Resistant with a relative humidity up to 98% at ambient temperature, degree Celsius: +35

Minimum bending radius of the cables, diameters of the cable: 10

Service life, years, not less: 30

Smoke generation in the test cell: not more than 50 %

Test category on the flame retardance : А

Equivalent toxicity index, g/m3 , more than : 40

Fire resistance cables, min, not less: 180

 

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483-2012, with the cross-section from 1.5 to 6 mm2.

Thermal barrier

Mica tape winding

Insulation

For cables of types KPvBShvng(A)-FRLS – cross-linked, halogen free polymer composition.

For cables of types KPBShvng(A)-FRLS – thermoplastic, cross-linked, halogen free polymer composition.

Core arrangement and twisting

Number of conductors from 4 to 61.

The insulated conductors are twisted in a cable core.

The cables have a digital and color coded marking of the conductors.

Inner sheath

It is made by extrusion with filling with the halogen free polymer compositions.

Cable armoring

It is laid helically with two steel, galvanized tapes.

It is possible to lay the PET-tapes by winding or longitudinally over the armor.

Cable sheath or jacket

PVC-compound of low fire hazard.

By category
Control cables
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR) / Armored
Insulation
Copper
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPvBShvng(A)-FRLS
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
4х1,5 17,3 1580
5х1,5 18,4 1910
7х1,5 19,5 2552
10х1,5 23,2 651
14х1,5 24,9 730
19х1,5 27,1 820
27х1,5 31,4 1129
37х1,5 34,9 1297
52х1,5 40,1 1529
61х1,5 42,3 2013
4х2,5 18,3 2468
5х2,5 19,5 3223
7х2,5 20,7 3579
10х2,5 25 742
14х2,5 26,7 839
19х2,5 29,1 954
27х2,5 34,2 1345
37х2,5 37,7 1548
4х4 19,4 2499
5х4 20,8 3049
7х4 22,1 4027
10х4 26,9 861
4х6 20,7 982
5х6 22,1 1133
7х6 23,9 1617
10х6 28,9 1005