Products

Search by features


КВВГЭнг(А)-LS (KVVGЕng(A)-LS)

КВВГЭнг(А)-LS (KVVGЕng(A)-LS)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Shielded
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg

Number of conductors, nominal cross-section (mm2), construction, voltage (kV)

KVVGЕng(A)-LS
Calculated diameter of cable, mm Calculated weight of cable, kg/km
4x1 10,5 154
5x1 11,1 178
7x1 11,7 209
10x1 13,9 276
14x1 14,7 339
19x1 16,0 420
27x1 18,8 574
37x1 20,6 729
52x1 24,0 992
4x1,5 11,0 179
5x1,5 11,7 210
7x1,5 12,4 250
10x1,5 14,8 334
14x1,5 15,7 416
19x1,5 17,1 521
27x1,5 20,2 718
37x1,5 22,3 921
4x2,5 11,9 228
5x2,5 12,7 271
7x2,5 13,6 329
10x2,5 16,3 445
14x2,5 17,4 566
19x2,5 19,4 741
27x2,5 22,6 999
37x2,5 25,3 1325
4x4 13,6 312
5х4 14,5 376
7x4 15,6 466
10x4 19,4 659
4x6 14,7 400
5х6 15,9 484
7x6 17,0 612
10x6 21,3 869

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage 660V of frequency 100 Hz or direct voltage up to 1000V, for group installation with taking into account the volume of combustible load of the cables, in cable structures and premises of indoor electric units including residential and public buildings.

The screened cables are used when it is necessary to protect the electrical circuits from the influence of external electric fields.

The climate modification УХЛ and T, categories of location 1 and 5 according to GOST 15150.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.2.2.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

PVC-compound of low flammability.

Core arrangement and twisting

From 4 to 127 insulated conductors.

The insulated conductors are twisted; there is a marker pair in each layer. It is allowed digital and color coded marking of the conductors.

Separating layer

PVC-compound of low flammability.

Screen

For cables of types KVVGЕng(A)-LS is made in the form of taping with aluminum polyethylene tape.

Over sheath

PVC-compound of low fire hazard.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Shielded
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg

Number of conductors, nominal cross-section (mm2), construction, voltage (kV)

KVVGЕng(A)-LS
Calculated diameter of cable, mm Calculated weight of cable, kg/km
4x1 10,5 154
5x1 11,1 178
7x1 11,7 209
10x1 13,9 276
14x1 14,7 339
19x1 16,0 420
27x1 18,8 574
37x1 20,6 729
52x1 24,0 992
4x1,5 11,0 179
5x1,5 11,7 210
7x1,5 12,4 250
10x1,5 14,8 334
14x1,5 15,7 416
19x1,5 17,1 521
27x1,5 20,2 718
37x1,5 22,3 921
4x2,5 11,9 228
5x2,5 12,7 271
7x2,5 13,6 329
10x2,5 16,3 445
14x2,5 17,4 566
19x2,5 19,4 741
27x2,5 22,6 999
37x2,5 25,3 1325
4x4 13,6 312
5х4 14,5 376
7x4 15,6 466
10x4 19,4 659
4x6 14,7 400
5х6 15,9 484
7x6 17,0 612
10x6 21,3 869