Products

Search by features


КВВГнг(А)-FRLS (KVVGng(A)-FRLS)

КВВГнг(А)-FRLS (KVVGng(A)-FRLS)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVVGng(A)-FRLS
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х0,75 FE180 10,3 134
5х0,75 FE180 11,2 163
7х0,75 FE180 12,1 199
10х0,75 FE180 15,2 274
14х0,75 FE180 16,5 351
19х0,75 FE180 18,7 470
27х0,75 FE180 22,3 637
37х0,75 FE180 25,3 856
52х0,75 FE180 29,7 1155
4х1,0 FE180 10,6 148
5х1,0 FE180 11,6 181
7х1,0 FE180 12,6 223
10х1,0 FE180 15,8 307
14х1,0 FE180 17,1 397
19х1,0 FE180 19,5 532
27х1,0 FE180 23,2 724
37х1,0 FE180 26,4 976
52х1,0 FE180 30,9 1321
4х1,5 FE180 11,2 170
5х1,5 FE180 12,2 210
7х1,5 FE180 13,2 258
10х1,5 FE180 16,7 357
14х1,5 FE180 18,5 484
19х1,5 FE180 20,6 624
27х1,5 FE180 25 879
37х1,5 FE180 28 1151
4х2,5 FE180 12,1 216
5х2,5 FE180 13,2 267
7х2,5 FE180 14,4 336
10х2,5 FE180 18,6 488
14х2,5 FE180 20,2 638
19х2,5 FE180 22,5 829
27х2,5 FE180 27,3 1171
37х2,5 FE180 30,6 1546
4х4 FE180 13,7 297
5х4 FE180 15 370
7х4 FE180 16,4 471
10х4 FE180 21,3 683
4х6 FE180 14,9 383
5х6 FE180 16,4 481
7х6 FE180 18,3 637
10х6 FE180 23,7 918

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz or direct voltage up to 1000V, for group installation with taking into account the volume of combustible load of the cables in the fire protection systems and other systems that must remain operational in case of fire within 180 minutes.

The class of fire hazard of the cables according to GOST 31565 П1б.1.2.2.2.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Thermal barrier

The lapping with two mica tapes.

Insulation

PVC-compound of low fire hazard.

Core arrangement

From 4 to 127 insulated conductors.

The insulated conductors are twisted; there is a marker pair in each layer.

It is allowed digital and color coded marking of the conductors.

Cable sheath or jacket

PVC-compound of low fire hazard.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVVGng(A)-FRLS
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х0,75 FE180 10,3 134
5х0,75 FE180 11,2 163
7х0,75 FE180 12,1 199
10х0,75 FE180 15,2 274
14х0,75 FE180 16,5 351
19х0,75 FE180 18,7 470
27х0,75 FE180 22,3 637
37х0,75 FE180 25,3 856
52х0,75 FE180 29,7 1155
4х1,0 FE180 10,6 148
5х1,0 FE180 11,6 181
7х1,0 FE180 12,6 223
10х1,0 FE180 15,8 307
14х1,0 FE180 17,1 397
19х1,0 FE180 19,5 532
27х1,0 FE180 23,2 724
37х1,0 FE180 26,4 976
52х1,0 FE180 30,9 1321
4х1,5 FE180 11,2 170
5х1,5 FE180 12,2 210
7х1,5 FE180 13,2 258
10х1,5 FE180 16,7 357
14х1,5 FE180 18,5 484
19х1,5 FE180 20,6 624
27х1,5 FE180 25 879
37х1,5 FE180 28 1151
4х2,5 FE180 12,1 216
5х2,5 FE180 13,2 267
7х2,5 FE180 14,4 336
10х2,5 FE180 18,6 488
14х2,5 FE180 20,2 638
19х2,5 FE180 22,5 829
27х2,5 FE180 27,3 1171
37х2,5 FE180 30,6 1546
4х4 FE180 13,7 297
5х4 FE180 15 370
7х4 FE180 16,4 471
10х4 FE180 21,3 683
4х6 FE180 14,9 383
5х6 FE180 16,4 481
7х6 FE180 18,3 637
10х6 FE180 23,7 918