Products

Search by features


ВВГ-Пнг(А)-FRХЛ (VVG-Png(A)-FRKhL)

ВВГ-Пнг(А)-FRХЛ (VVG-Png(A)-FRKhL)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Fireproof (-FR) / Cold-resistant (-HL)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated width of cable, mm Calculated height of cable, mm Calculated weight of cable, kg/km
2х1,5ок(N)-0,66  9,7 6,0 97
2х2,5ок(N)-0,66  10,5 6,4 121
2х4ок(N)-0,66  11,9 7,0 165
2х6ок(N)-0,66  12,8 7,5 210
2х10ок(N)-0,66  15,8 9,3 335
2х16ок(N)-0,66  17,6 10,2 461
3х1,5ок(N,PE)-0,66  13,5 6,0 141
3х2,5ок(N,PE)-0,66  14,7 6,4 178
3х4ок(N,PE)-0,66  16,7 7,0 244
3х6ок(N,PE)-0,66  18,2 7,5 312
3х10ок(N,PE)-0,66  22,4 9,3 497
3х16ок(N,PE)-0,66  25,1 10,2 687
2х1,5ок(N)-1 10,5 6,4 109
2х2,5ок(N)-1 11,3 6,8 134
2х4ок(N)-1 13,1 7,6 187
2х6ок(N)-1 14,0 8,1 234
2х10ок(N)-1 16,2 9,5 345
2х16ок(N)-1  18,0 10,4 471
3х1,5ок(N,PE)-1  14,7 6,4 159
3х2,5ок(N,PE)-1 15,9 6,8 197
3х4ок(N,PE)-1 18,5 7,6 277
3х6ок(N,PE)-1 20,0 8,1 347
3х10ок(N,PE)-1 23,0 9,5 511
3х16ок(N,PE)-1 25,7 10,4 702

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 0.66 and 1kV and frequency 50 Hz or at direct voltage 1 and 1.5 kV with the possibility of installation without preheat at temperatures up to minus 300C.

The cables are used at group installation of cable lines in cable structures, outdoor (open-air) electric units (cable racks and galleries). Fire resisting cables in modification “flame retardant – Fire-Resistant Cold-Resistant” keep working in terms of exposure by the flame for 180 minutes.

For manufacturing of the cables the materials which provide resistance of the cables to the impact of ambient low temperature to minus 600C are used.

The class of fire hazard of the cables according to GOST П1б.1.2.5.4.

STRUCTURE

Conductor

Copper, single-wire core to 16 mm2 of circular form of the 1 class according to GOST 22483

Thermal barrier

The lapping with two fiber glass mica tapes.

Insulation

PVC-compound of low flammability (color coded conductor)

Core arrangement and twisting

Insulated conductors of 2, 3 core cables are arranged in parallel in one flat .

Inner sheath

PVC-compound of low flammability is made of filling of outer space between conductors.

Over sheath

Nominal voltage, kV 0,66 or 1 PVC-compound of low flammability

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Fireproof (-FR) / Cold-resistant (-HL)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated width of cable, mm Calculated height of cable, mm Calculated weight of cable, kg/km
2х1,5ок(N)-0,66  9,7 6,0 97
2х2,5ок(N)-0,66  10,5 6,4 121
2х4ок(N)-0,66  11,9 7,0 165
2х6ок(N)-0,66  12,8 7,5 210
2х10ок(N)-0,66  15,8 9,3 335
2х16ок(N)-0,66  17,6 10,2 461
3х1,5ок(N,PE)-0,66  13,5 6,0 141
3х2,5ок(N,PE)-0,66  14,7 6,4 178
3х4ок(N,PE)-0,66  16,7 7,0 244
3х6ок(N,PE)-0,66  18,2 7,5 312
3х10ок(N,PE)-0,66  22,4 9,3 497
3х16ок(N,PE)-0,66  25,1 10,2 687
2х1,5ок(N)-1 10,5 6,4 109
2х2,5ок(N)-1 11,3 6,8 134
2х4ок(N)-1 13,1 7,6 187
2х6ок(N)-1 14,0 8,1 234
2х10ок(N)-1 16,2 9,5 345
2х16ок(N)-1  18,0 10,4 471
3х1,5ок(N,PE)-1  14,7 6,4 159
3х2,5ок(N,PE)-1 15,9 6,8 197
3х4ок(N,PE)-1 18,5 7,6 277
3х6ок(N,PE)-1 20,0 8,1 347
3х10ок(N,PE)-1 23,0 9,5 511
3х16ок(N,PE)-1 25,7 10,4 702