Products

Search by features


КУППнг(А)-HF (KUPPng(A)-HF)

КУППнг(А)-HF (KUPPng(A)-HF)
Price on request
₽0
By category
Cables for monitoring and control circuits
Voltage
250
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Shielded
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KUPPng(A)-HF
Number of strands, area (mm2), version
Design cable size, mm Design cable weight, kg/km
2* 7,8 58
2 7,8 54
4 9,9 105
8 12,6 173
12 15,3 250
16 16,9 314
20 18,4 376
32 22,8 577
40 25,0 697

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed to transmit signals of up to 250VAC, 50 Hz or up to 350VDC/300mA when connecting detectors and actuators to SCADA hardware and software and to be used in the process areas outside the containment building of nuclear power stations, classes 3N, 3U, 4N and 4U as per NP-001 (rules and regulations).

Climate version B, siting category 5, atmosphere type IV (coastal industrial) as per GOST 15150 Zerohalogen, non corrosive gases: GOST IEC 60754-2

Fire retardant: GOST IEC 60332-3-22

Smoky density: GOST IEC 61034-2

The class of fire hazard of the cables according to GOST R 31565 P1b.8.1.2.1.

STRUCTURE

Number of pairs in the cable

12; 4; 8; 12; 16; 20; 32 and 40.

Current-carrying conductor

Copper or tin-plated copper, nominal diameter 0.8 mm (area 0.5 mm2).

Insulation 

Halogen-free polymer composition. Color coded.

Core arrangement and twisting

Two insulated colour-coded strands are twisted into a pair. 

The pairs are twisted into elementary four-pair bundles, with elementary bundles twisted into a core.

Belt insulation

PET-E tapes wound (helically with overlap) over the twisted core (two- and four-pair cable) or elementary bundle.

Screen

Aluminium polymer tape wrapping (helically with overlap) and tin-plated copper contact wire.

Over sheath

Grey Halogen-free polymer composition.


The cables are designed to connect to equipment using Maxi-Termi-Point technology 

Salt-resistant cables 

Dust-resistant cables 

The cables are unaffected by exposure to earthquakes up to MSK magnitude 9

By category
Cables for monitoring and control circuits
Voltage
250
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Shielded
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KUPPng(A)-HF
Number of strands, area (mm2), version
Design cable size, mm Design cable weight, kg/km
2* 7,8 58
2 7,8 54
4 9,9 105
8 12,6 173
12 15,3 250
16 16,9 314
20 18,4 376
32 22,8 577
40 25,0 697