Products

Search by features


КВБбШвнг(А) (KVBbShvng(A))

КВБбШвнг(А) (KVBbShvng(A))
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Armored
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVBbShvng(A)
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 12,1 263
5х1,0 12,8 293
7х1,0 13,4 330
10х1,0 15,5 422
14х1,0 16,4 494
19х1,0 17,7 579
27х1,0 20,1 739
37х1,0 21,9 906
52х1,0 25,3 1194
4х1,5 12,7 294
5х1,5 13,4 331
7х1,5 14,1 379
10х1,5 16,4 488
14х1,5 17,4 583
19х1,5 18,8 692
27х1,5 21,5 895
37х1,5 23,9 1137
4х2,5 13,6 354
5х2,5 14,4 405
7х2,5 15,2 474
10х2,5 18 610
14х2,5 19,1 742
19х2,5 20,7 910
27х2,5 24,3 1220
37х2,5 26,6 1541
4х4 15,2 454
5х4 16,2 528
7х4 17,2 627
10х4 20,6 830
4х6 16,4 555
5х6 17,5 650
7х6 18,7 784
10х6 22,6 1061

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz or direct voltage up to 1000V for installation in the premises, conduits, tunnels, in conditions of aggressive environment, in the absence of mechanical effects on cable.

It is possible to lay the cable in the ground (trenches) where the places of the exit of the cable from the ground to the surface are protected. The cables are used for installation in cable structures and spaces for providing of fire safety.

The class of fire hazard of the cables according to GOST 31565 01.8.2.5.4.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

PVC-compound.

Core arrangement

From 4 to 127 insulated conductors.

The insulated conductors are twisted; there is a marker pair in each layer.

Separating layer

PVC-compound or a layer with the PET tape.

Cable armoring

For cables of type KVBbShvng(A) is laid helically with two steel, galvanized tapes.

Over sheath or jacket

PVC-compound of low flammability

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Armored
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVBbShvng(A)
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 12,1 263
5х1,0 12,8 293
7х1,0 13,4 330
10х1,0 15,5 422
14х1,0 16,4 494
19х1,0 17,7 579
27х1,0 20,1 739
37х1,0 21,9 906
52х1,0 25,3 1194
4х1,5 12,7 294
5х1,5 13,4 331
7х1,5 14,1 379
10х1,5 16,4 488
14х1,5 17,4 583
19х1,5 18,8 692
27х1,5 21,5 895
37х1,5 23,9 1137
4х2,5 13,6 354
5х2,5 14,4 405
7х2,5 15,2 474
10х2,5 18 610
14х2,5 19,1 742
19х2,5 20,7 910
27х2,5 24,3 1220
37х2,5 26,6 1541
4х4 15,2 454
5х4 16,2 528
7х4 17,2 627
10х4 20,6 830
4х6 16,4 555
5х6 17,5 650
7х6 18,7 784
10х6 22,6 1061