Products

Search by features


КППГнг(А)-HF (KPPGng(A)-HF)

КППГнг(А)-HF (KPPGng(A)-HF)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF)
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGng(A)-HF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 9,9 163
5х1,0 10,6 188
7х1,0 11,2 223
10х1,0 13,5 305
14х1,0 14,4 368
19х1,0 15,7 451
27х1,0 18,1 595
37х1,0 19,9 752
52х1,0 22,9 996
4х1,5 10,5 191
5х1,5 11,2 222
7х1,5 11,9 268
10х1,5 14,4 369
14х1,5 15,4 451
19х1,5 16,8 559
27х1,5 19,5 745
37х1,5 21,5 950
4х2,5 9,4 166
5х2,5 10,2 203
7х2,5 11 258
10х2,5 13,8 360
14х2,5 14,9 475
19х2,5 16,5 620
27х2,5 20,1 880
37х2,5 22,4 1167
4х4 11 241
7х4 13 384
10х4 16,4 538
4х6 12,2 322
7х6 14,5 522
10х6 18,8 755

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of nominal electric power and electric signals at the stationary installation on the nominal alternating voltage 660 V of nominal frequency up to 100 Hz including for use in NPP systems of class 3H according to classification ОПБ-88/97 (ПНАЭ Г-01-011).

The cables recommended, especially for use at nuclear power stations, large thermal power stations, petrochemical objects, in the subway, on ships; buildings with mass stay of people: concert halls and indoor stadiums, theatres, airports and railway stations; in premises, equipped with computer and microprocessor appliances and other objects which have increased requirements for fire safety.

The class of fire hazard of the cables according to GOST 31565 П1б.8.1.2.1.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 1 to 6 mm2.

Insulation

Halogen-free polymer composition.

Core arrangement

From 4 to 52 insulated conductors.

The insulated conductors of the cables are twisted.

Control cables have distinctive markings of insulated conductors (digital or color).

Inner sheath

Halogen-free polymer composition.

Over sheath or jacket

Of halogen-free polymer composition.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF)
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGng(A)-HF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 9,9 163
5х1,0 10,6 188
7х1,0 11,2 223
10х1,0 13,5 305
14х1,0 14,4 368
19х1,0 15,7 451
27х1,0 18,1 595
37х1,0 19,9 752
52х1,0 22,9 996
4х1,5 10,5 191
5х1,5 11,2 222
7х1,5 11,9 268
10х1,5 14,4 369
14х1,5 15,4 451
19х1,5 16,8 559
27х1,5 19,5 745
37х1,5 21,5 950
4х2,5 9,4 166
5х2,5 10,2 203
7х2,5 11 258
10х2,5 13,8 360
14х2,5 14,9 475
19х2,5 16,5 620
27х2,5 20,1 880
37х2,5 22,4 1167
4х4 11 241
7х4 13 384
10х4 16,4 538
4х6 12,2 322
7х6 14,5 522
10х6 18,8 755