КППГнг(А)-FRHF (KPPGng(A)-FRHF)

КППГнг(А)-FRHF (KPPGng(A)-FRHF)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGng(A)-FRHF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Outside diameter of cable, mm Calculated weight of cable, kg/km The volume of the fuel mass, l / km
4х1 12,3 220 100
5х1 13,5 258 116
7х1 14,5 311 134
10х1 17,8 426 180
14х1 19,1 519 208
19х1 21 645 249
27х1 25,4 902 349
37х1 28,2 1144 425
52х1 32,9 1522 548
4х1,5 12,9 254 108
5х1,5 14,2 300 125
7х1,5 15,2 366 145
10х1,5 18,8 503 196
14х1,5 20,2 620 227
19х1,5 22,3 777 271
27х1,5 27 1088 379
37х1,5 30 1391 463
52х1,5 35,4 1898 620
4х2,5 14,1 324 126
5х2,5 15,3 376 141
7х2,5 16,4 465 163
10х2,5 20,4 645 221
14х2,5 22 807 256
19х2,5 24,9 1060 331
27х2,5 29,5 1434 429
37х2,5 32,8 1852 523
52х2,5 38,8 2539 701
4х4 15,7 431 155
7х4 18,5 633 203
10х4 23,1 884 278
4х6 17 542 175
7х6 20 811 229
10х6 25,7 1176 340

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz for group installation with taking into account the volume of combustible load of the cables in the fire protection systems and other systems that must remain capacity for work case of fire within 180 minutes.

The cables are manufactured for use at nuclear power stations (NPP) outside the containment area in systems of NPP of class 2 according to classification OPB 88/97 (PNAE G-01-011) as well as at large thermal power stations, petrochemical objects, in the subway, in buildings and structures with mass stay of people, concert halls and indoor stadiums, theatres, airports and railway stations; in premises, equipped with computer and microprocessor appliances and other objects which have increased requirements for fire safety.

The class of fire hazard of the cables according to GOST 31565 П1б.1.1.2.1.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 1.0 to 6 mm2.

Thermal barrier

The lapping with mica tapes.

Insulation

Halogen free polymer composition.

Core arrangement

Number of conductors from 4 to 52.

The insulated conductors are twisted in the cable core, the conductors are color-coded, which provide the identification of each core during installation.

Color-coded is solid or in the form of longitudinal strips of a width not less than 1mm.

Inner sheath

Halogen free polymer composition.

Cable sheath

Halogen free polymer composition.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Shell
Polymer composition
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPPGng(A)-FRHF
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Outside diameter of cable, mm Calculated weight of cable, kg/km The volume of the fuel mass, l / km
4х1 12,3 220 100
5х1 13,5 258 116
7х1 14,5 311 134
10х1 17,8 426 180
14х1 19,1 519 208
19х1 21 645 249
27х1 25,4 902 349
37х1 28,2 1144 425
52х1 32,9 1522 548
4х1,5 12,9 254 108
5х1,5 14,2 300 125
7х1,5 15,2 366 145
10х1,5 18,8 503 196
14х1,5 20,2 620 227
19х1,5 22,3 777 271
27х1,5 27 1088 379
37х1,5 30 1391 463
52х1,5 35,4 1898 620
4х2,5 14,1 324 126
5х2,5 15,3 376 141
7х2,5 16,4 465 163
10х2,5 20,4 645 221
14х2,5 22 807 256
19х2,5 24,9 1060 331
27х2,5 29,5 1434 429
37х2,5 32,8 1852 523
52х2,5 38,8 2539 701
4х4 15,7 431 155
7х4 18,5 633 203
10х4 23,1 884 278
4х6 17 542 175
7х6 20 811 229
10х6 25,7 1176 340