КПвБПнг(А)-FRHF - (KPvBPng(A)-FRHF)

КПвБПнг(А)-FRHF - (KPvBPng(A)-FRHF)
Price on request
₽0
By category
Control cables
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPvBPng(A)-FRHF
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
4х1,5 17,3 1559
5х1,5 18,4 1886
7х1,5 19,5 2522
10х1,5 23,2 640
14х1,5 24,9 717
19х1,5 27,1 807
27х1,5 31,4 1113
37х1,5 34,9 1279
52х1,5 40,1 1508
61х1,5 42,3 1989
4х2,5 18,3 2438
5х2,5 19,5 3189
7х2,5 20,7 3544
10х2,5 25 729
14х2,5 26,7 825
19х2,5 29,1 940
27х2,5 34,2 1327
37х2,5 37,7 1528
4х4 19,4 2471
5х4 20,8 3017
7х4 22,1 3990
10х4 26,9 848
4х6 20,7 968
5х6 22,1 1118
7х6 23,9 1597
10х6 28,9 990

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary installations, for installation in cable structures, buildings and underground structures, including flammable and explosive areas as well as for the power circuits of the equipment that operates in the fire.

The class of fire hazard of the cables according to GOST 31565-2012 П1б.1.1.2.1

 

TECHNICAL DATA

Nominal voltage, kV: 0,66

Ambient temperature during cable operation, °С: from -50 to +50

Resistant with a relative humidity up to 98% at ambient temperature, °С: +35

Minimum bending radius of the cables, diameters of the cable: 10

Service life, years, not less: 40

Fire resistance of the cable, minutes, not less than: 180

Smoke generation in the test cell: not more than 40%

Test category on the flame retardance: А

Equivalent index of toxicity, g/m3 , more: 40

 

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483-2012, with the cross-section from 1.5 to 6 mm2.

Thermal barrier

Mica tape winding.

Insulation

For cables of types KPvBPng(A)- FRHF – cross-linked, halogen free polymer composition.

For cables of types KPBPng(A)- FRHF – thermoplastic, halogen free polymer composition.

Core arrangement

The number of conductors from 4 to 61. The insulated conductors are twisted in a cable core. The cables have a digital and color coded marking of the insulated conductors.

Inner sheath

It is made by halogen free, polymer composition extrusion with the filling.

Cable armoring

It is laid helically with two steel, galvanized tapes.

It is possible to lay the PET-tapes by winding or longitudinally over the armor.

Cable sheath or jacket

Halogen free polymer composition.

By category
Control cables
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPvBPng(A)-FRHF
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
4х1,5 17,3 1559
5х1,5 18,4 1886
7х1,5 19,5 2522
10х1,5 23,2 640
14х1,5 24,9 717
19х1,5 27,1 807
27х1,5 31,4 1113
37х1,5 34,9 1279
52х1,5 40,1 1508
61х1,5 42,3 1989
4х2,5 18,3 2438
5х2,5 19,5 3189
7х2,5 20,7 3544
10х2,5 25 729
14х2,5 26,7 825
19х2,5 29,1 940
27х2,5 34,2 1327
37х2,5 37,7 1528
4х4 19,4 2471
5х4 20,8 3017
7х4 22,1 3990
10х4 26,9 848
4х6 20,7 968
5х6 22,1 1118
7х6 23,9 1597
10х6 28,9 990