Products

Search by features


КВБбШв (KVBbShv)

КВБбШв (KVBbShv)
Price on request
₽0
By category
Force cables
Voltage
660
In execution
For a single pad / Armored
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVBbShv
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
7х1,0 13,4 324
10х1,0 15,5 415
14х1,0 16,4 486
19х1,0 17,7 570
27х1,0 20,1 728
37х1,0 21,9 895
52х1,0 25,3 1179
4х1,5 12,7 288
5х1,5 13,4 324
7х1,5 14,1 372
10х1,5 16,4 480
14х1,5 17,4 574
19х1,5 18,8 682
27х1,5 21,5 884
37х1,5 23,9 1124
4х2,5 13,6 348
5х2,5 14,4 398
7х2,5 15,2 466
10х2,5 18 601
14х2,5 19,1 733
19х2,5 20,7 899
27х2,5 24,3 1206
37х2,5 26,6 1525
4х4 15,2 447
7х4 17,2 618
10х4 20,6 819
4х6 16,4 547
7х6 18,7 775
10х6 22,6 1049

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz or direct voltage up to 1000V.

The cables of type KVBbShv are used for installation in the premises, conduits, tunnels, in conditions of aggressive environment and in areas exposed to stray currents, if the cable was not subjected to significant tensile force.

The class of fire hazard of the cables according to GOST 31565 01.8.2.5.4.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

PVC-compound.

Core arrangement

From 4 to 61 insulated conductors.

The insulated conductors are twisted, there is a marker pair in each layer.

Separating layer

PVC-compound or a layer with the PET tape.

Cable armoring

For cables of types KVBbShv is laid helically with two steel, galvanized tapes.

Over sheath or jacket

PVC-compound.

By category
Force cables
Voltage
660
In execution
For a single pad / Armored
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVBbShv
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
7х1,0 13,4 324
10х1,0 15,5 415
14х1,0 16,4 486
19х1,0 17,7 570
27х1,0 20,1 728
37х1,0 21,9 895
52х1,0 25,3 1179
4х1,5 12,7 288
5х1,5 13,4 324
7х1,5 14,1 372
10х1,5 16,4 480
14х1,5 17,4 574
19х1,5 18,8 682
27х1,5 21,5 884
37х1,5 23,9 1124
4х2,5 13,6 348
5х2,5 14,4 398
7х2,5 15,2 466
10х2,5 18 601
14х2,5 19,1 733
19х2,5 20,7 899
27х2,5 24,3 1206
37х2,5 26,6 1525
4х4 15,2 447
7х4 17,2 618
10х4 20,6 819
4х6 16,4 547
7х6 18,7 775
10х6 22,6 1049