Search by features
-
Power cables of nominal voltage up to 3kv
- Power cables for single installation
- VVG, AVVG, VVGE, AVVGE, VBShV, AVBShV, according to specification 16-705.4992010
- VVG-P, AVVG-P, according to specification 16-705.499-2010
- VVG, AVVG, VVGz, AVVGz, VBbShV, AVBbShV, VVG-P, AVVG-P, according to GOST 16442-80
- VVG-KhL, AVVG-KhL, VVGE-KhL, AVVGE-KhL, VBShv-KhL, AVBShv-KhL, VVG-P-KhL, AVVG-P-KhL
- VVGg-KhL, AVVGg-KhL, VVGEg-KhL, AVVGEg-KhL, VBShvg-KhL, AVBShvg-KhL, according to specification 16.K121-017-2011
- VBaShv-KhL, AVBaShv-KhL, VKaShv-KhL, VKShv-KhL, AVKShv-KhL, AVKaShv-KhL, according to specification 16.K121-017-2011
- PvVG, APvVG, PvVGE, APvVGE, PvBShv, APvBShv, PvVG-P, APvVG-P, PvBShP, APvBShP, according to specification 16-705.499-2010
- PvVG-KhL, APvVG-KhL, PvVGE-KhL, APvVGE -KhL, PvVG-P-KhL, APvVG-P-KhL, PVBShv-KhL, APVBShv-KhL, PVBaShv-KhL, APVBaShv-KhL, PvKShv-KhL, APvKShv-KhL, PvKaShv-KhL, APvKaShv-KhL, according to specification 16.K121-017-2011
- ПвВГ-ХЛ (PvVG-KhL)
- АПвВГ-ХЛ (APvVG-KhL)
- ПвВГЭ-ХЛ (PvVGE-KhL)
- АПвВГЭ-ХЛ (APvVGE-KhL)
- ПвВГ-П-ХЛ (PvVG-P-KhL)
- АПвВГ-П-ХЛ (APvVG-P-KhL)
- ПвБШв-ХЛ (PvBShv-KhL)
- АПвБШв-ХЛ (APvBShv-KhL)
- ПвБаШв-ХЛ (PvBaShv-KhL)
- АПвБаШв-ХЛ (APvBaShv-KhL)
- ПвКШв-ХЛ (PvKShv-KhL)
- АПвКШв-ХЛ (APvKShv-KhL)
- ПвКаШв-ХЛ (PvKaShv-KhL)
- АПвКаШв-ХЛ (APvKaShv-KhL)
- NYM-J, NYM-O according to specifications 3521-002-53972660-2007
- NY(F)2Y-J
- Power cables flame retardant at group installation (modification "flame retardant")
- Power cables with plastic insulation flame retardant at group installation in cold-resistant modification
- VVGng(A)-KhL, AVVGng(A)-KhL, VVGEng(A)-KhL, AVVGEng(A)-KhL, VBShvng(A)–KhL, АVBShvng(A), VVG-Png(A)-KhL, AVVG-Png(A)-KhL, according to specifications 16.K121-017-2011
- VBAShvng (A)-KhL, AVBAShvng(A)-KhL, VKShvng(A)-KhL, AVKShvng(A)-KhL, VKaShvng(A)-KhL, AVKaShvng(A)-KhL, according to specifications 16.K121-017-2011
- PvVGng(A)-KhL, APvVGng(A)-KhL, PvVG-Png(A)-KhL, APvVG-Png(A)-KhL, PvVGEng(A)-KhL, APvVGEng(A)-KhL, PvBShvng(A)-KhL, APvBShvng(A)-KhL, PvBaShvng(A)-KhL, APvBaShvng(A)-KhL, PvKShvng(A)-KhL, APvKShvng(A)-KhL, PvKaShvng(A)-KhL, APvKaShvng(A)-KhL
- ПвВГнг(А)-ХЛ (PvVGng(A)-KhL)
- АПвВГнг(А)-ХЛ (APvVGng(A)-KhL)
- ПвВГ-Пнг(А)-ХЛ (PvVG-Png(A)-KhL)
- АПвВГ-Пнг(А)-ХЛ (APvVG-Png(A)-KhL)
- ПвВГЭнг(А)-ХЛ (PvVGEng(A)-KhL)
- АПвВГЭнг(А)-ХЛ (APvVGEng(A)-KhL)
- ПвБШвнг(А)-ХЛ (PvBShvng(A)-KhL)
- АПвБШвнг(А)-ХЛ (APvBShvng(A)-KhL)
- ПвБаШвнг(А)-ХЛ (PvBaShvng(A)-KhL)
- АПвБаШвнг(А)-ХЛ (APvBaShvng(A)-KhL)
- ПвКШвнг(А)-ХЛ (PvKShvng(A)-KhL)
- АПвКШвнг(А)-ХЛ (APvKShvng(A)-KhL)
- ПвКаШвнг(А)-ХЛ (PvKaShvng(A)-KhL)
- АПвКаШвнг(А)-ХЛ (APvKaShvng(A)-KhL)
- VGng (A)-KhL, AVVGng (A)-KhL, VVGEng (A)-KhL, AVVGEng (A)-KhL, VBShVng (A)–KhL, AVBShVng (A)–KhL, VBaShVng (A)–KhL, AVBaShVng (A)–KhL, VeBShvng (A)–KhL, AVeBShvng (A)–KhL, VeBShvng (A)–KhL, АVeBShvng (A)–KhL, according to specifications 16.K121-027-20133
- ВВГнг(А)-ХЛ (VVGng(A)-KhL)
- АВВГнг(А)-ХЛ (AVVGng(A)-KhL)
- ВВГЭнг(А)-ХЛ (VVGEng(A)-KhL)
- АВВГЭнг(А)-ХЛ (AVVGEng(A)-KhL)
- ВБШвнг(А)-ХЛ (VBShVng(A)–KhL)
- АВБШвнг(А)-ХЛ (AVBShVng(A)–KhL)
- ВБаШвнг(А)-ХЛ (VBaShVng(A)–KhL)
- АВБаШвнг(А)-ХЛ (AVBaShVng(A)–KhL)
- ВЭБШвнг(А)-ХЛ (VEBShvng(A)–KhL)
- АВЭБШвнг(А)-ХЛ (AVEBShvng(A)–KhL)
- ВЭБаШвнг(А)-ХЛ (VEBaShvng(A)–KhL)
- АВЭБаШвнг(А)-ХЛ (АVEBaShvng(A)–KhL)
- VVGgng(A)-KhL, AVVGgng(A)-KhL, VVGEgng(A)-KhL, AVVGEgng(A)-KhL, VBShVgng(A)–KhL, AVBShVgng(A)–KhL, VBaShVgng(A)–KhL, AVBaShVgng(A)–KhL, VeBShvgng(A)–KhL, AVeBShvgng(A)–KhL, VeBShvgng(A)–KhL, АVeBShvgng(A)–KhL
- ВВГгнг(А)-ХЛ (VVGgng(A)-KhL)
- АВВГгнг(А)-ХЛ (AVVGgng(A)-KhL)
- ВВГЭгнг(А)-ХЛ (VVGEgng(A)-KhL)
- АВВГЭгнг(А)-ХЛ (AVVGEgng(A)-KhL)
- ВБШвгнг(А)-ХЛ (VBShvgng(A)-KhL)
- АВБШвгнг(А)-ХЛ (AVBShvgng(A)-KhL)
- ВБаШвгнг(А)-ХЛ (VBaShvgng(A)-KhL)
- АВБаШвгнг(А)-ХЛ (AVBaShvgng(A)-KhL)
- ВЭБШвгнг(А)-ХЛ (VEBShvgng(A)-KhL)
- АВЭБШвгнг(А)-ХЛ (AVEBShvgng(A)-KhL)
- ВЭБаШвгнг(А)-ХЛ (VEBaShvgng(A)-KhL)
- АВЭБаШвгнг(А)-ХЛ (АVEBaShvgng(A)-KhL)
- VVG-Png(A)-Kh-L, AVVG-Png(A)-Kh-L, VVG-Pgng(A)-Kh-L, AVVG-Pgng(A)-Kh-L, according to specifications 16.K121-027-2013
- Power cables with plastic insulation, flame retardant at group installation with low smoke- and gas emission
- VVGng(A)-LS, AVVGng(A)-LS, VVGEng(A)-LS, AVVGEng(A)-LS, VBShvng(A)-LS, AVBShvng(A)-LS, according to specifications 16 .K71-310-2001
- VVG-Png(A)-LS, AVVG-Png(A)-LS, according to specifications respectively, 16.K71-310-2001
- VVGng(A)-LS, AVVGng(A)-LS, VVGEng(A)-LS, AVVGEng(A)-LS, VBShvng(A)-LS, AVBShvng(A)-LS, according to specifications 16 .K121-018-2011
- VVG-Png(A)-LS, AVVG-Png(A)-LS, according to specifications 16.K121-018-2011
- PvVGng(A)-LS, APvVGng(A)-LS, PvVGЕng(A)-LS, APvVGЕng(A)-LS, PvBShvng(A)-LS, АPvBShvng(A)-LS, according to specifications 16 .K121-018-2011
- PvVGng(A)-LS, PvVGЕng(A)-LS,PvBShvng(A)-LS according to specifications 16.K71-480-2015
- Power cables with xlpe insulation, flame retardant at group installation with low smoke- and gas emission
- Power cables, flame retardant at group installation and not emitting corrosive active gaseous products at burning and smouldering (modification "flame retardant – halogen-free")
- PPGng(A)-HF, PPGEng(A)-HF, PBPng(A)-HF, PPGgng(A)-HF, PPGEgng(A)-HF, PBPgng(A)-HF, according to specifications 16.K121-023-2011
- PvPGng(A)-HF, PvPGEng(A)-HF, according to specifications 16.K71-341-2004
- PPGng(A)-HF, PPGЕng(A)-HF, PBPng(A)-HF, PvPGng(A)-HF, according to specifications 16.K71-304-2001
- PvPGng(A)-HF, PvPGEng(A)-HF, PvBPng(A)-HF, according to specifications 16.K71-480-2015
- Power cables, fire-resisting, flame retardant at group installation, with low smoke- and gas emission (modification "flame retardant – "fire-resistant low smoke")
- VVGng(A)-FRLS, VVGЕng(A)-FRLS, VBShvng(A)-FRLS, VVG-Png(A)-FRLS, according to specifications 16.K121-022-2011
- VVGng(A)-FRLS, VVGЕng(A)-FRLS, according to specifications 16.K71-337-2004
- PvVGng(A)-FRLS, PvVGEng(A)-FRLS, PvBShvng(A)-FRLS, according to specifications 16.K121-022-2011
- PvVGng(A)-FRLS, according to specifications 16.K71-341-2004
- RVGng(A)-FRLS, RVG-Рng(A)-FRLS, RVGЕng(A)-FRLS, according to specifications 16.K121-026-2013
- PvVGng(A)-FRLS, PvVGEng(A)-FRLS, PvBShvng(A)-FRLS according to specifications 16.K71-480-2015
- Low-toxic power cables flame retardant at group installation with low smokeand gas emission
- Power cables fire-resistant flame retardant at group installation, which do not emmit toxic corrosive active gaseous products while burning and smouldering (modification "flame retardant – fire-resistant halogen-free")
- PvPGng(A)-FRHF, PvPGЕng(A)-FRHF, according to specifications 16.K71-341-2004
- PvPGng-FRHF, PvPGEng-FRHF, PvBPng-FRHF, PvPGgng-FRHF, PvPGEgng-FRHF, PvBPgng-FRHF, according to specifications 16.K121-023-2011
- PPGng(A)-FRHF, PPGЕng(A)-FRHF, PBPng(A)-FRHF, according to specifications 16.K71-341-2004
- PPGng(A)-FRHF, PPGЕng(A)-FRHF, PvPGng(A)-FRHF, PvPGEng(A)-FRHF, according to specifications 16.K71-339-2014
- RPGng(A)-FRHF, RPGEng(A)-FRHF, RPG-Png(A)-FRHF, according to specifications 16.K121-026-2013
- PvPGng(A)-FRHF, PvPGEng(A)-FRHF, PvBPng(A)-FRHF according to specifications16.K71-480-2015
- Power cables fire-resisting with plastic insulation flame retardant at group installation in cold-resistant modification with the temperature of cable installation up to -30 degrees below zero
- Power cables for single installation
-
Power cables for rated voltage up to 6 kV
- VVG, AVVG, VVGg, AVVGg, VBV, AVBV, VBVg, AVBVg, according to specifications 16.K121-028-2013
- PvPGng(A)-HF, PvPGng(A)-HF according to specifications 16.K71-480-2015
- KVEBShv, KVEBShv(u), according to specifications 16.K121-024-2013
- VVG, AVVG, VBV, АVBV, according to specifications 16.K71-359-2005
- KVEBShvng(A), KVEBShv(u)ng(A), according to specifications 16. K121-024-2013
- VVGng(A), AVVGng(A), VVGgng(A), AVVGgng(A), VBVng(A), AVBVng(A), VBVgng(A), AVBVgng(A), according to specifications 16.K121-028-2013
- VBVng(A), AVBVng(A), according to specifications 16.K71-359-2005
- KVEBShv-KhL, KVEBShv(u)-KhL, according to specifications 16.K121-024-2013
- KVEBShvng(A)KhL, KVEBShv(u)ng(A)KhL, according to specifications 16.K121-024-2013
- VVGng(A)-LS, AVVGng(A)-LS, VVGgng(A)-LS, АVVGgng(A)-LS, VBVng(A)-LS, AVBVng(A)-LS, VBVgng(A)-LS, AVBVgng(A)-LS, according to specifications 16.K121-028-2013
- KVEBShvng(A)-FRLS, KVEBShv(u)ng(A)-FRLS according to specifications 16.K121-024-2013
- KVEBShvng(A)-FRKhL, KVEBShv(u)ng(A)-FRKhL according to specifications 16.K121-024-2013
- PvVGng(A)-LS, PvBShvng(A)-LS according to specifications 16.K71-480-2015
-
Control cables
- KVVG, KVVGz, KVVGE, KVBbShv, according to GOST 1508-78
- KVVGng(A), KVVGzng(A), KVVGЕng(A), KVBbShvng(A), KVBbShvzng(A), according to specifications 3563-004-53972660-2008
- KVVGng(A)-KhL, KVVGzng(A)-KhL, KVVGЕng(A)-KhL, KVBbShvng(A)-KhL, KVVG-Png(A)-KhL, according to specifications 16.K121-012-2013
- KVVGng(A)-KhL, KVVGЕng(A)-KhL, KVBbShvng(A)-KhL, KVVGgng(A)-KhL, KVVGЕgng(A)-KhL, KVBbShvgng(A)-KhL, according to specifications 16.K121-030-2013
- KVVGng(A)- FRLSLTx, KVVGЕng(A)- FRLSLTx, KVBbShvng(A)- FRLSLTx according to specifications 3563-010-53972660-2010
- KVVGng(A)-LS, KVVGEng(A)-LS, according to specifications 16.K71-310-2001
- KVVGng(A)-LS, KVVGzng(A)-LS, KVVGЕng(A)-LS, KVBbShvng(A)-LS, KVVG-Png(A)-LS, according to specifications 3563-010-53972660-2010
- KPPGng(A)-HF, KPPGЕng(A)-HF, KPBPng(A)-HF, according to specifications 16.K71-304-2001
- KPPGng(A)-HF, KPPGЕng(A)-HF, KPBbPng(A)-HF, according to specifications 16.K121-029-2013
- KVVGng(A)-FRLS, KVVGЕng(A)-FRLS, according to specifications 16.K71-337-2004
- KVVGng(A)-FRLS, KVVGЕng(A)-FRLS, KVBbShvng(A)-FRLS, according to specifications 3563-010-53972660-2010
- KPPGng(A)-FRHF, KPPGЕng(A)-FRHF, according to specifications 16.K71-339-2004
- KPPGng(A)-FRHF, KPPGЕng(A)-FRHF, KPBbPng(A)-FRHF, according to specifications 16.K121-029-2014
- KPBPng(A)- FRHF, KPvBPng(A)-FRHF according to specifications 16.K71-480-2015
- KVVGng(A)-FRKhL, KVVGЕng(A)-FRKhL, KVBbShvng(A)-FRKhL, according to specifications 16.K121-030-2013
- KPBShvng(A)-FRLS, KPvBShvng(A)-FRLS according to specifications 16.K71-480-2015
- KPBPng(A)- HF, KPvBPng(A)- HF according to specifications 16.K71-480-2015
- KPBShvng(A)-LS, KPvBShvng(A)-LS according to specifications 16.К71-480-2015
- KVVGng(A)- LSLTx, KVVGzng(A)- LSLTx, KVVGЕng(A)- LSLTx, KVBbShvng(A)- LSLTx, KVVG-Png(A)- LSLTx according to specifications 3563-010-53972660-2010
- Wires, cords and connecting cables
-
Wires and cables for electrical units
- PuV, PuGV, PuVV, PuGVV, KuVV, KuGVV, according to specifications 16-705.501-2010
- PV1, PV1-KhL, PV2, PV2-KhL, PV3, PV3-KhL, PV4, PV4-KhL, PPV, PPV-KhL, АPV, АPV-KhL, according to GOST 6323-79
- PuVng(A)-LS, PuGVng(A)-LS, PuVVng(A)-LS, PuGVVng(A)-LS, KuVVng(A)-LS, KuGVVng(A)-LS, according to specifications 16-705.502-2011
- KuRVng(A)-FRLS, KuGRVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuREVng(A)-FRLS, KuGREVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuRKVng(A)-FRLS, KuGRKVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuREVKVng(A)-FRLS, KuGREVKVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuRPng(A)-FRHF, KuGRPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuREPng(A)-FRHF, KuGREPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuRKPng(A)-FRHF, KuGRKPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuREPKPng(A)-FRHF, KuREPKPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuRVng(A)-FRLSTx, KuGRVng(A)-FRLSTx, according to specifications 16-K121-025-2013
- KuRKVng(A)-FRLSTx, KuGRKVng(A)-FRLSTx, according to specifications 16-K121-025-2013
- KuREVng(A)-FRLSTx, KuREVng(A)-FRLSTx, according to specifications 16-K121-025-2013
-
Cables for Fire Alarm Systems
- КPSVVng(А)-LS, КPSVVGng(А)-LS, КPSVEVng(А)-LS, КPSVEVGng(А)-LS, КPSVEEVng(А)-LS, КPSVEEVGng(А)-LS, according to specifications 16.K121-020-2011
- КPSng(А)-FRLS, КPSGng(А)-FRLS, КPSEng(А)-FRLS, КPSEGng(А)-FRLS, КPSEEng(А)-FRLS, КPSEEGng(А)-FRLS, according to specifications 16.K121-021-2011
- KPSng(A)-FRHF, KPSGng(A)-FRHF, KPSEng(A)-FRHF, KPSEGng(A)-FRHF, KPSEEng(A)-FRHF, KPSЕEGng(A)-FRHF, according to specifications 16.K121-021-2011
- KPSSng(A)-FRLS, KPSSGng(A)-FRLS, KPSESng(A)-FRLS, KPSESGng(A)-FRLS, according to specifications 16.K121-021-2011
- KPSSng(A)-FRHF, KPSSGng(A)-FRHF, KPSESng(A)-FRHF, KPSESGng(A)-FRHF, according to specifications 16.K121-021-2011
- KPSSng(A)-FRLSLTx, KPSSGng(A)-FRLSLTx, KPSЕSng(A)-FRLSLTx,KPSЕSGng(A)-FRLSLTx according to specifications 16.K121-021-2011
-
Cables for monitoring and control circuits
- KUGVVng(A)-LS, KUGVEVng(A)-LS, KUGVVEng(A)-LS, according to specifications 16.K71-310-2001
- KUGVVng(A)-FRLS, KUGVEVng(A)-FRLS, KUGVVЕng(A)-LS, according to specifications 16.K71-337-2004
- KUPPng(A)-HF, KUPPlng(A)-HF, according to specifications 3561-411-00217053-2009
- KUPPmng(A)-HF, KUPPmng(A)-FRHF, KUPEfPmng(A)-HF, KUPEfPmng(A)-FRHF, according to specifications 3561-441-00217053-2012
- KUPPng(A)-FRHF, KUPPlng(A)-FRHF, according to specifications 3561-442-00217053-2012
- KUGPvEPvng(A)-HF-LOCA, KUGPvEPvng(A)-HF-T-LOCA, KUGPvEPvng(A)-FRHF-LOCA, KUGPvEPvng(A)-FRHF-T-LOCA, KUGPvEPvng(A)-HF, KUGPvEPvng(A)-HF-T, KUGPvEPvng(A)-FRHF, KUGPvEPvng(A)-FRHF-T according to specifications 16.К71-451-2012
- КУГПвЭПвнг(А)-HF-LOCA (KUGPvEPvng(A)-HF-LOCA)
- КУГПвЭПвнг(А)-HF (KUGPvEPvng(A)-HF)
- КУГПвЭПвнг(А)-HF-Т-LOCA (KUGPvEPvng(A)-HF-T-LOCA)
- КУГПвЭПвнг(А)-HF-Т (KUGPvEPvng(A)-HF-T)
- КУГПвЭПвнг(А)-FRHF-LOCA (KUGPvEPvng(A)-FRHF-LOCA)
- КУГПвЭПвнг(А)-FRHF (KUGPvEPvng(A)-FRHF)
- КУГПвЭПвнг(А)-FRHF-Т-LOCA (KUGPvEPvng(A)-FRHF-T-LOCA)
- КУГПвЭПвнг(А)-FRHF-Т (KUGPvEPvng(A)-FRHF-T)
- Small-size cables
-
Cables for control systems and alarm
- KPEPng(A)-HF, KGPEPng(A)-HF, KUGPPng(A)-HF, KUGPPEng(A)-HF, KUGPPEPng(A)-HF, KUGPEPng(A)-HF, KUGEPPng(A)-HF, KUGEPPEng(A)-HF, KUGEPPEPng(A)-HF, according to specifications 16.K71-338-2004
- KPEPng(A)-FRHF, KGPEPng(A)-FRHF, KUGPPng(A)-FRHF, KUGPPЕng(A)-FRHF, KUGPPЕРng(A)-FRHF, KUGPЕРng(A)-FRHF, KUGЕРРng(A)-FRHF, KUGЕРРЕng(A)-FRHF, KUGЕРРЕРng(A)-FRHF, according to specifications 16.K71-338-2004
- КПЭПнг(А)-FRHF (KPEPng(A)-FRHF)
- КГПЭПнг(А)-FRHF (KGPEPng(A)-FRHF)
- КУГППнг(А)-FRHF (KUGPPng(A)-FRHF)
- КУГППЭнг(А)-FRHF (KUGPPЕng(A)-FRHF)
- КУГППЭПнг(А)-FRHF (KUGPPЕРng(A)-FRHF)
- КУГПЭПнг(А)-FRHF (KUGPЕРng(A)-FRHF)
- КУГЭППнг(А)-FRHF (KUGЕРРng(A)-FRHF)
- КУГЭППЭнг(А)-FRHF (KUGЕРРЕng(A)-FRHF)
- КУГЭППЭПнг(А)-FRHF (KUGЕРРЕРng(A)-FRHF)
-
Telephone cables
- TVBPng(A)-HF – Russian analogue of J-2YF(St)H… Bd, А-2YF(L)H..BD, TVBPBbPng(A)-HF – Russian analogue of J-2YF(St)BH according to Specification 16.K71-468-2015
- TVBVng(A)-LS – Russian analogue of J-2YF(St)Y… Bd, А-2YF(L)Y..BD Flame Retardant Low Smoke, TVBVBbShvng(A)-LS – Russian analogue of J-2YF(St)BY Flame Retardant Low Smoke according to Specification 16.K71-468-2015
КВБбШв (KVBbShv)

- By category
- Force cables
- Voltage
- 660
- In execution
- For a single pad / Armored
- Insulation
- Copper
- Shell
- PVC insulation
- Core material
- Flexible PVC
- Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVBbShv Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km 7х1,0 13,4 324 10х1,0 15,5 415 14х1,0 16,4 486 19х1,0 17,7 570 27х1,0 20,1 728 37х1,0 21,9 895 52х1,0 25,3 1179 4х1,5 12,7 288 5х1,5 13,4 324 7х1,5 14,1 372 10х1,5 16,4 480 14х1,5 17,4 574 19х1,5 18,8 682 27х1,5 21,5 884 37х1,5 23,9 1124 4х2,5 13,6 348 5х2,5 14,4 398 7х2,5 15,2 466 10х2,5 18 601 14х2,5 19,1 733 19х2,5 20,7 899 27х2,5 24,3 1206 37х2,5 26,6 1525 4х4 15,2 447 7х4 17,2 618 10х4 20,6 819 4х6 16,4 547 7х6 18,7 775 10х6 22,6 1049
SCOPE AND PURPOSE
The cables are designed for fixed connection to electrical devices and equipment to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz or direct voltage up to 1000V.
The cables of type KVBbShv are used for installation in the premises, conduits, tunnels, in conditions of aggressive environment and in areas exposed to stray currents, if the cable was not subjected to significant tensile force.
The class of fire hazard of the cables according to GOST 31565 01.8.2.5.4.
STRUCTURE
Conductor
Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.
Insulation
PVC-compound.
Core arrangement
From 4 to 61 insulated conductors.
The insulated conductors are twisted, there is a marker pair in each layer.
Separating layer
PVC-compound or a layer with the PET tape.
Cable armoring
For cables of types KVBbShv is laid helically with two steel, galvanized tapes.
Over sheath or jacket
PVC-compound.
- By category
- Force cables
- Voltage
- 660
- In execution
- For a single pad / Armored
- Insulation
- Copper
- Shell
- PVC insulation
- Core material
- Flexible PVC
- Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVBbShv Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km 7х1,0 13,4 324 10х1,0 15,5 415 14х1,0 16,4 486 19х1,0 17,7 570 27х1,0 20,1 728 37х1,0 21,9 895 52х1,0 25,3 1179 4х1,5 12,7 288 5х1,5 13,4 324 7х1,5 14,1 372 10х1,5 16,4 480 14х1,5 17,4 574 19х1,5 18,8 682 27х1,5 21,5 884 37х1,5 23,9 1124 4х2,5 13,6 348 5х2,5 14,4 398 7х2,5 15,2 466 10х2,5 18 601 14х2,5 19,1 733 19х2,5 20,7 899 27х2,5 24,3 1206 37х2,5 26,6 1525 4х4 15,2 447 7х4 17,2 618 10х4 20,6 819 4х6 16,4 547 7х6 18,7 775 10х6 22,6 1049