Products

Search by features


КВВГзнг(А)-LS (KVVGzng(A)-LS)

КВВГзнг(А)-LS (KVVGzng(A)-LS)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVVGzng(A)-LS
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4x1 7,5 101
5x1 8,2 121
7x1 9,4 166
10x1 11,5 229
14x1 12,4 286
19x1 13,7 362
27x1 16,1 490
37x1 17,9 635
52x1 21,3 883
4x1,5 8,1 125
5x1,5 9,4 166
7x1,5 10,1 206
10x1,5 12,4 286
14x1,5 13,4 362
19x1,5 14,8 462
27x1,5 17,5 630
37x1,5 19,9 844
4x2,5 9,6 186
5x2,5 10,4 226
7x2,5 11,2 285
10x2,5 14 397
14x2,5 15,1 511
19x2,5 16,7 659
27x2,5 20,3 929
37x2,5 22,6 1219
4x4 11,2 270
5х4 12,2 330
7x4 13,2 422
10x4 16,6 593
4x6 12,4 359
5х6 13,5 438
7x6 14,7 570
10x6 19 827

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage 660V of frequency 100 Hz or direct voltage up to 1000V, for group installation with taking into account the volume of combustible load of the cables, in cable structures and premises of indoor electric units including residential and public buildings.

The climate modification УХЛ and T, categories of location 1 and 5 according to GOST 15150.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.2.2.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

PVC-compound of low flammability.

Core arrangement and twisting

From 4 to 127 insulated conductors.

The insulated conductors are twisted; there is a marker pair in each layer. It is allowed digital and color coded marking of the conductors.

Separating layer

PVC-compound of low flammability.

Over sheath

PVC-compound of low fire hazard.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS)
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVVGzng(A)-LS
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4x1 7,5 101
5x1 8,2 121
7x1 9,4 166
10x1 11,5 229
14x1 12,4 286
19x1 13,7 362
27x1 16,1 490
37x1 17,9 635
52x1 21,3 883
4x1,5 8,1 125
5x1,5 9,4 166
7x1,5 10,1 206
10x1,5 12,4 286
14x1,5 13,4 362
19x1,5 14,8 462
27x1,5 17,5 630
37x1,5 19,9 844
4x2,5 9,6 186
5x2,5 10,4 226
7x2,5 11,2 285
10x2,5 14 397
14x2,5 15,1 511
19x2,5 16,7 659
27x2,5 20,3 929
37x2,5 22,6 1219
4x4 11,2 270
5х4 12,2 330
7x4 13,2 422
10x4 16,6 593
4x6 12,4 359
5х6 13,5 438
7x6 14,7 570
10x6 19 827