Products

Search by features


ВВГ-П (VVG-P)

ВВГ-П (VVG-P)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
For a single pad
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-P
Number of conductors Calculated dimensions of cable, mm Calculated weight of cable, kg/km
height width
2х1,5ок(N)-0,66 5,5 8,1 76
2х2,5ок(N)-0,66 5,8 8,9 99
2х4ок(N)-0,66 6,5 10,2 140
2х6ок(N)-0,66 7 11,2 183
2х10ок(N)-0,66 8,2 13,6 283
2х16ок(N)-0,66 9,3 15,6 409
3х1,5ок(N,PE)-0,66 5,5 10,8 108
3х2,5ок(N,PE)-0,66 5,8 11,9 142
3х4ок(N,PE)-0,66 6,5 13,9 204
3х6ок(N,PE)-0,66 7 15,4 268
3х10ок(N,PE)-0,66 8,2 19 418
3х16ок(N,PE)-0,66 9,3 21,9 606
2х1,5ок(N)-1 5,9 8,9 86
2х2,5ок(N)-1 6,2 9,7 110
2х4ок(N)-1 7,1 11,4 158
2х6ок(N)-1 7,6 12,4 203
2х10ок(N)-1 8,4 14 290
2х16ок(N)-1 9,5 16 417
3х1,5ок(N,PE)-1 5,6 12 122
3х2,5ок(N,PE)-1 6,2 13,1 158
3х4ок(N,PE)-1 7,1 15,7 231
3х6ок(N,PE)-1 7,6 17,2 298
3х10ок(N,PE)-1 8,4 19,6 429
3х16ок(N,PE)-1 9,5 22,5 619

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electricity in fixed electrical installations on a nominal alternating voltage 0,66, 1 and 3 kV, frequency - 50 Hz.

Cables of types VVG-P are designed for laying single cable lines in cable installations and premises.

Cables of types VVG-P in a single-conductor modification is designed for use in DC voltage.

The class of fire hazard of the cables is according to GOST 31565 01.8.2.5.4.

STRUCTURE

Conductor

Aluminum or copper core, single-wire, circular form, 1 class according to GOST 22483.

Numbers of conductors

2 or 3

Nominal cross-section area of main conductors, mm2

Copper 1,5-16

Aluminum 2,5-16

Stranding

Insulated cores are laid parallel in one flat.

Insulation

PVC- compound (color coded conductor).

Over sheath or protective covering

PVC-compound

By category
Force cables
Voltage
660 / 1000
In execution
For a single pad
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-P
Number of conductors Calculated dimensions of cable, mm Calculated weight of cable, kg/km
height width
2х1,5ок(N)-0,66 5,5 8,1 76
2х2,5ок(N)-0,66 5,8 8,9 99
2х4ок(N)-0,66 6,5 10,2 140
2х6ок(N)-0,66 7 11,2 183
2х10ок(N)-0,66 8,2 13,6 283
2х16ок(N)-0,66 9,3 15,6 409
3х1,5ок(N,PE)-0,66 5,5 10,8 108
3х2,5ок(N,PE)-0,66 5,8 11,9 142
3х4ок(N,PE)-0,66 6,5 13,9 204
3х6ок(N,PE)-0,66 7 15,4 268
3х10ок(N,PE)-0,66 8,2 19 418
3х16ок(N,PE)-0,66 9,3 21,9 606
2х1,5ок(N)-1 5,9 8,9 86
2х2,5ок(N)-1 6,2 9,7 110
2х4ок(N)-1 7,1 11,4 158
2х6ок(N)-1 7,6 12,4 203
2х10ок(N)-1 8,4 14 290
2х16ок(N)-1 9,5 16 417
3х1,5ок(N,PE)-1 5,6 12 122
3х2,5ок(N,PE)-1 6,2 13,1 158
3х4ок(N,PE)-1 7,1 15,7 231
3х6ок(N,PE)-1 7,6 17,2 298
3х10ок(N,PE)-1 8,4 19,6 429
3х16ок(N,PE)-1 9,5 22,5 619