Products

Search by features


AВБВгнг(А)-LS (AVBVgng(A)-LS)

AВБВгнг(А)-LS (AVBVgng(A)-LS)
Price on request
₽0
By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Armored
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVBVgng(A)-LS
Cables with circular conductors
with aluminum conductor
Number and nom. cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x16/16 39 2014
3x25/16 41,9 2296
3x35/16 44,2 2557
3x50/16 47,3 2952
3x70/16 51 3398
3x95/16 54,5 3898
3x120/16 57,9 4455
3x150/25 61 4994
3x185/25 64,9 5611
3x240/25 70,7 6743
AVBVgng(A)-LS
Cables with sector-shaped conductors
with aluminum conductor
Number and nom. cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 41,1 2033
3x50/16 43,5 2281
3x70/16 46,2 2617
3x95/16 48,9 2962
3x120/16 51,5 3310
3x150/25 54 3773
3x185/25 57,4 4266
3x240/25 61,6 4948

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 6kV of frequency 50 Hz for networks with the earthed and insulated neutral.

The climate modification УХЛ, categories of location 1 and 5 according to GOST 15150, including installation in the ground.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.2.2.

STRUCTURE

Conductor

Aluminum, single-wire or multi-wire, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

Is made of PVC-compound of low fire hazard (color coded conductor).

Core arrangement

Insulated conductors of multi-core cables are twisted in a cable core.

Inner sheath

It is made by extrusion with PVC-compound of low fire hazard or chalk-filled non-cured rubber with the filling of outer gaps between insulated conductors. It is possible to fill the outer gaps between circular insulated cores with the bundles of with the lapping of fastening tape and extrusion inner sheath. It is allowed to wrap the cable core with the tapes of polymer material.

Taping

Layer of water blocking tapes.

Screen

Of copper wires and a spirally imposed copper tape. It is allowed the application of the screen with copper tapes.

Separating layer

Layer of water blocking tapes.

Bedding

Of PVC-compound of low fire hazard.

Cable armoring

Is lapped helically with two steel, galvanized tapes.

Over sheath

Of PVC-compound of low fire hazard.

By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Armored
Insulation
Aluminum
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
AVBVgng(A)-LS
Cables with circular conductors
with aluminum conductor
Number and nom. cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x16/16 39 2014
3x25/16 41,9 2296
3x35/16 44,2 2557
3x50/16 47,3 2952
3x70/16 51 3398
3x95/16 54,5 3898
3x120/16 57,9 4455
3x150/25 61 4994
3x185/25 64,9 5611
3x240/25 70,7 6743
AVBVgng(A)-LS
Cables with sector-shaped conductors
with aluminum conductor
Number and nom. cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 41,1 2033
3x50/16 43,5 2281
3x70/16 46,2 2617
3x95/16 48,9 2962
3x120/16 51,5 3310
3x150/25 54 3773
3x185/25 57,4 4266
3x240/25 61,6 4948