Products

Search by features


ВВГгнг(А) (VVGgng(A))

ВВГгнг(А) (VVGgng(A))
Price on request
₽0
By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А))
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVGgng(A)
Cables with circular conductors
with copper conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
1x16/16 20 627
1x25/16. 21,3 739
1x35/16 22,4 858
1x50/16 23,5 1029
1x70/16 25 1250
1x95/16 26,8 1518
1x120/16 28 1781
1x150/25 30,1 2174
1x185/25 31,9 2537
1x240/25 34,1 3093
1x300/25 36,3 3692
1x400/35 39,4 4763
1x500/35 42,1 5739
1x630/35 45,9 7037
1x800/35 49,6 8672
VVGgng(A)
Cables with circular conductors
with copper conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x16/16 35 1603
3x25/16 37,9 1993
3x35/16 40,1 2396
3x50/16 43,1 2974
3x70/16 47 3763
3x95/16 50,5 4665
3x120/16 53,4 5582
3x150/25 57,1 6670
3x185/25 60,8 7871
3x240/25 65,5 9763
VVGgng(A)
Cables with sector-shaped conductors
with copper conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 37,1
3x50/16 39,2 2421
3x70/16 41,9 3044
3x95/16 44,5 3808
3x120/16 47,5 4610
3x150/25 50 5589
3x185/25 52,9 6636
3x240/25 57,4 8317

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 6kV of frequency 50 Hz for networks with the earthed and insulated neutral.

The climate modification УХЛ, categories of location 1 and 5 according to GOST 15150, including installation in the ground.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.5.4.

STRUCTURE

Conductor

Copper, single-wire or multi-wire, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

Is made of PVC-compound (color coded conductor).

Core arrangement

Insulated conductors of multi-core cables are twisted in a cable core.

Inner sheath

It is made by extrusion with PVC-compound of low flammability or chalk-filled non-cured rubber with the filling of outer gaps between insulated conductors. It is possible to fill the outer gaps between circular insulated cores with the bundles of with the lapping of fastening tape and extrusion inner sheath. It is allowed to wrap the cable core with the tapes of polymer material.

Taping

In waterproof cables – a layer of water blocking tapes.

Screen

Of copper wires and a spirally imposed copper tape. It is allowed the application of the screen with copper tapes.

Separating layer

In waterproof cables – a layer of water blocking tapes.

Over sheath

Of PVC-compound of low flammability.

By category
Force cables
Voltage
6000
In execution
Flame retardant (-ng(А))
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVGgng(A)
Cables with circular conductors
with copper conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
1x16/16 20 627
1x25/16. 21,3 739
1x35/16 22,4 858
1x50/16 23,5 1029
1x70/16 25 1250
1x95/16 26,8 1518
1x120/16 28 1781
1x150/25 30,1 2174
1x185/25 31,9 2537
1x240/25 34,1 3093
1x300/25 36,3 3692
1x400/35 39,4 4763
1x500/35 42,1 5739
1x630/35 45,9 7037
1x800/35 49,6 8672
VVGgng(A)
Cables with circular conductors
with copper conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x16/16 35 1603
3x25/16 37,9 1993
3x35/16 40,1 2396
3x50/16 43,1 2974
3x70/16 47 3763
3x95/16 50,5 4665
3x120/16 53,4 5582
3x150/25 57,1 6670
3x185/25 60,8 7871
3x240/25 65,5 9763
VVGgng(A)
Cables with sector-shaped conductors
with copper conductor
Number and nom. Cross-section of CCC and screens, nxmm2 External diameter, mm Weight of 1km of cable, kg
3x35/16 37,1
3x50/16 39,2 2421
3x70/16 41,9 3044
3x95/16 44,5 3808
3x120/16 47,5 4610
3x150/25 50 5589
3x185/25 52,9 6636
3x240/25 57,4 8317