Products

Search by features


ПвПГЭнг(А)-FRHF (PvPGEng(A)-FRHF)

ПвПГЭнг(А)-FRHF (PvPGEng(A)-FRHF)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR) / Shielded
Insulation
Copper
Shell
Crosslinked polyethylene
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
5х1,5ок(N,PE)-0,66 15,7 393
5х2,5ок(N,PE)-0,66 17,0 482
5х4ок(N,PE)-0,66 18,6 613
5х6ок(N,PE)-0,66 20,0 750
5х10ок(N,PE)-0,66 22,1 1017
5х16ок(N,PE)-0,66 25,1 1407
5х25ок(N,PE)-0,66 29,3 2010
5х35ок(N,PE)-0,66 32,0 2555
5х50ок(N,PE)-0,66 35,8 3303
3х70мс(N,PE)-1 35,4 3088
3х95ок(N,PE)-1 38,6 3938
3х120мс(N,PE)-1 41,6 4739
3х150ок(N,PE)-1 45,9 5772
3х185мс(N,PE)-1 49,8 6971
3х240мс(N,PE)-1 54,9 8792
4х70мс(PE)-1 39,6 3948
4х95ок(PE)-1 43,4 5062
4х120мс(PE)-1 47,7 6232
4х150ок(PE)-1 51,6 7461
4х185мс(PE)-1 57,0 9175
4х240мс(PE)-1 62,5 11540

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power in the fixed networks on the nominal alternating voltage 0.66 and 1kV and nominal frequency 50 Hz.

The cables are used for group installation of cable power lines of safety systems, wiring circuits of fire safety, (the wiring circuits of systems of fire alarm, power of pumps of fire suppression, illuminations of emergency exits and escape routes, smoke removal systems and ventilation, evacuation lifts).

For wiring in the surgical departments of hospitals, of the wiring circuits of emergency power supply of the equipment (current collectors), functioning in case of fire. It keeps working in case of fire during 180 (FE180) or 240 (FE240) minutes.

The class of fire hazard of the cables according to GOST 31565 П1б.1.1.2.1.

STRUCTURE

Conductor

Copper, single-wire or multi-wire core, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483 with the cross-section from 1.5 to 1000mm2

Thermal barrier for CCC (current-carrying conductor)

The overlapping with two mica tapes.

Insulation

XLPE.

Core arrangement

Insulated conductors of 2, 3, 4 and 5 core cables are twisted in a cable core.

Inner sheath

Halogen-free polymer composition.

Thermal barrier

Lapped with mica or fiber glass tapes.

Additional thermal barrier (for “FE240”)

Taped with fiber glass mica tapes.

Screen

For cables of types PvPGEng-FRHF is made of lapping with copper tapes or of copper wires and a spirally imposed copper tape.

Separating layer

For cables of types PvPGEng-FRHF is made of is made in the form of overlapping with fiber glass or mica tapes.

Over sheath or jacket

Of halogen-free polymer composition.

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR) / Shielded
Insulation
Copper
Shell
Crosslinked polyethylene
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
5х1,5ок(N,PE)-0,66 15,7 393
5х2,5ок(N,PE)-0,66 17,0 482
5х4ок(N,PE)-0,66 18,6 613
5х6ок(N,PE)-0,66 20,0 750
5х10ок(N,PE)-0,66 22,1 1017
5х16ок(N,PE)-0,66 25,1 1407
5х25ок(N,PE)-0,66 29,3 2010
5х35ок(N,PE)-0,66 32,0 2555
5х50ок(N,PE)-0,66 35,8 3303
3х70мс(N,PE)-1 35,4 3088
3х95ок(N,PE)-1 38,6 3938
3х120мс(N,PE)-1 41,6 4739
3х150ок(N,PE)-1 45,9 5772
3х185мс(N,PE)-1 49,8 6971
3х240мс(N,PE)-1 54,9 8792
4х70мс(PE)-1 39,6 3948
4х95ок(PE)-1 43,4 5062
4х120мс(PE)-1 47,7 6232
4х150ок(PE)-1 51,6 7461
4х185мс(PE)-1 57,0 9175
4х240мс(PE)-1 62,5 11540