Products

Search by features


РВГЭнг(А)-FRLS (RVGЕng(A)-FRLS)

РВГЭнг(А)-FRLS (RVGЕng(A)-FRLS)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR) / Shielded
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
2х1,5ок(N)-0,66  11,5 226
2х2,5ок(N)-0,66  12,3 266
2х4ок(N)-0,66  13,6 337
2х6ок(N)-0,66  14,6 405
3х1,5ок(N,PE)-0,66  12,0 248
3х2,5ок(N,PE)-0,66  12,8 298
3х4ок(N,PE)-0,66  14,2 384
3х6ок(N,PE)-0,66  15,3 469
4х1,5ок(N)-0,66 12,7 282
4х2,5ок(N)-0,66  13,6 342
4х4ок(N)-0,66  15,2 448
4х6ок(N)-0,66  16,6 569
5х1,5ок(N,PE)-0,66  13,5 322
5х2,5ок(N,PE)-0,66  14,6 396
5х4ок(N,PE)-0,66 16,6 536
5х6ок(N,PE)-0,66 18,3 688
2х1,5ок(N)-1  12,3 253
2х2,5ок(N)-1 13,1 294
2х4ок(N)-1  14,4 369
2х6ок(N)-1  15,4 439
3х1,5ок(N,PE)-1  12,8 278
3х2,5ок(N,PE)-1  13,6 329
3х4ок(N,PE)-1  15,1 419
3х6ок(N,PE)-1 16,3 516
4х1,5ок(N)-1 13,7 316
4х2,5ок(N)-1  14,6 378
4х4ок(N)-1  16,4 498
4х6ок(N)-1  17,6 612
5х1,5ок(N,PE)-1 14,6 363
5х2,5ок(N,PE)-1  15,6 437
5х4ок(N,PE)-1  17,6 582
5х6ок(N,PE)-1  19,4 737

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power in stationary installations on the nominal alternating voltage to 0.66 and 1kV and frequency 50 Hz. The cables do not spread combustion at group stationary installation of cable lines, in the absence of mechanical effects and keep working when exposed to flame not less than 180 minutes.

They are designed for wiring and networks of the wiring circuits of emergency power supply of the equipment (current collectors), in residential and public buildings, in the surgical departments of hospitals, in office premises, equipped with computer and microprocessor devices, entertainment complexes and sports facilities, as well as at other objects with the high demand of fire safety.

The class of fire hazard of the cables according to GOST 31565 for cables П1б.1.2.2.2.

STRUCTURE

Number of conductors

From 1 to 5.

Conductor

Copper, of circular form, single-wire core, with the cross-section from 1.5 to 16mm2 or multiwire core with the cross-section from 10 to 16mm2

Insulation

Ceramics-forming rubber.

Core arrangement and twisting

For RVGЕng(A)-FRLS insulated conductors from 2 to 5 core cables twisted in a cable core.

Inner sheath

PVC-compound of low fire hazard.

Screen

For cables of types RVGЕng(A)-FRLS - copper tape.

Over sheath

PVC-compound of low fire hazard.

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Fireproof (-FR) / Shielded
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
2х1,5ок(N)-0,66  11,5 226
2х2,5ок(N)-0,66  12,3 266
2х4ок(N)-0,66  13,6 337
2х6ок(N)-0,66  14,6 405
3х1,5ок(N,PE)-0,66  12,0 248
3х2,5ок(N,PE)-0,66  12,8 298
3х4ок(N,PE)-0,66  14,2 384
3х6ок(N,PE)-0,66  15,3 469
4х1,5ок(N)-0,66 12,7 282
4х2,5ок(N)-0,66  13,6 342
4х4ок(N)-0,66  15,2 448
4х6ок(N)-0,66  16,6 569
5х1,5ок(N,PE)-0,66  13,5 322
5х2,5ок(N,PE)-0,66  14,6 396
5х4ок(N,PE)-0,66 16,6 536
5х6ок(N,PE)-0,66 18,3 688
2х1,5ок(N)-1  12,3 253
2х2,5ок(N)-1 13,1 294
2х4ок(N)-1  14,4 369
2х6ок(N)-1  15,4 439
3х1,5ок(N,PE)-1  12,8 278
3х2,5ок(N,PE)-1  13,6 329
3х4ок(N,PE)-1  15,1 419
3х6ок(N,PE)-1 16,3 516
4х1,5ок(N)-1 13,7 316
4х2,5ок(N)-1  14,6 378
4х4ок(N)-1  16,4 498
4х6ок(N)-1  17,6 612
5х1,5ок(N,PE)-1 14,6 363
5х2,5ок(N,PE)-1  15,6 437
5х4ок(N,PE)-1  17,6 582
5х6ок(N,PE)-1  19,4 737