Products

Search by features


КВБбШвнг(А)-ХЛ (KVBbShvng(A)-KhL)

КВБбШвнг(А)-ХЛ (KVBbShvng(A)-KhL)
Price on request
₽0
By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Cold-resistant (-HL) / Armored
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVBbShvng(A)-KhL
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
 4х1,0 11,9 250
5х1,0 12,6 277
7х1,0 13,2 313
10х1,0     15,3 402
14х1,0 16,2 471
19х1,0 17,5 557
27х1,0 19,9 712
37х1,0 21,7 878
52х1,0 25,1 1159
4х1,5 12,5 278
5х1,5 13,2 314
7х1,5 13,9 361
10х1,5     16,2 468
14х1,5 17,2 557
19х1,5 18,6 668
27х1,5 21,3 867
37х1,5 23,3 1081
4х2,5 13,4 337
5х2,5 14,2 387
7х2,5 15,0 452
10х2,5     17,8 588
14х2,5 18,9 718
19х2,5 20,5 883
27х2,5 24,1 1189
37х2,5 26,4 1504
4х4 15,0 435
5х4 16,0 508
7х4 17,0 607
10х4  20,4 803
4х6 16,2 535
5х6 17,3 629
7х6 18,5 760
10х6  22,4 1031

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment, to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz or direct voltage up to 1000V.

The cables are used at group installation of cable lines in cable structures, outdoor (open-air) electric units (cable racks and galleries) and they are designed for use at ambient low temperature from minus 600C to plus 500C.

For manufacturing of the cables the materials which provide resistance of the cables to the impact of ambient low temperature are used.

The armored cables are used in case of danger of mechanic damage in process of operation, if the cable is not exposed to significant tensile force.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.5.4.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

PVC-compound.

Core arrangement

From 4 to 127 insulated conductors. The insulated conductors are twisted; there is a marker pair in each layer. It is allowed a digital and color coded marking of the conductors.

Separating layer

PVC-compound or a layer with the PET tape.

Cable armoring

For cables of types KVBbShvng(A)-KhL is laid helically with two steel, galvanized tapes.

Over sheath

PVC-compound of low flammability.

By category
Control cables
Voltage
660
In execution
Flame retardant (-ng(А)) / Cold-resistant (-HL) / Armored
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVBbShvng(A)-KhL
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
 4х1,0 11,9 250
5х1,0 12,6 277
7х1,0 13,2 313
10х1,0     15,3 402
14х1,0 16,2 471
19х1,0 17,5 557
27х1,0 19,9 712
37х1,0 21,7 878
52х1,0 25,1 1159
4х1,5 12,5 278
5х1,5 13,2 314
7х1,5 13,9 361
10х1,5     16,2 468
14х1,5 17,2 557
19х1,5 18,6 668
27х1,5 21,3 867
37х1,5 23,3 1081
4х2,5 13,4 337
5х2,5 14,2 387
7х2,5 15,0 452
10х2,5     17,8 588
14х2,5 18,9 718
19х2,5 20,5 883
27х2,5 24,1 1189
37х2,5 26,4 1504
4х4 15,0 435
5х4 16,0 508
7х4 17,0 607
10х4  20,4 803
4х6 16,2 535
5х6 17,3 629
7х6 18,5 760
10х6  22,4 1031