Products

Search by features


РВГЭнг(А)-FRLSTx (RVGEng(A)-FRLSTx)

РВГЭнг(А)-FRLSTx (RVGEng(A)-FRLSTx)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Low toxicity (-LTx) / Fireproof (-FR) / Shielded
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
2х1,5ок(N)-0,66  11,5 231
2х2,5ок(N)-0,66  12,3 272
2х4ок(N)-0,66  13,6 344
2х6ок(N)-0,66  14,6 412
3х1,5ок(N,PE)-0,66  11,9 254
3х2,5ок(N,PE)-0,66  12,8 304
3х4ок(N,PE)-0,66  14,2 391
3х6ок(N,PE)-0,66  15,3 477
4х1,5ок(N)-0,66 12,7 288
4х2,5ок(N)-0,66  13,6 349
4х4ок(N)-0,66  15,2 456
4х6ок(N)-0,66  16,6 577
5х1,5ок(N,PE)-0,66  13,5 329
5х2,5ок(N,PE)-0,66  14,5 403
5х4ок(N,PE)-0,66 16,6 545
5х6ок(N,PE)-0,66 18,3 699
2х1,5ок(N)-1  12,3 259
2х2,5ок(N)-1 13,1 301
2х4ок(N)-1  14,4 376
2х6ок(N)-1  15,4 446
3х1,5ок(N,PE)-1  12,8 284
3х2,5ок(N,PE)-1  13,6 336
3х4ок(N,PE)-1  15,1 426
3х6ок(N,PE)-1 16,3 524
4х1,5ок(N)-1 13,7 323
4х2,5ок(N)-1  14,6 385
4х4ок(N)-1  16,4 506
4х6ок(N)-1  17,6 621
5х1,5ок(N,PE)-1 14,6 370
5х2,5ок(N,PE)-1  15,6 445
5х4ок(N,PE)-1  17,6 592
5х6ок(N,PE)-1  19,4 749

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power in stationary installations on the nominal alternating voltage to 0.66 and 1kV and frequency 50 Hz. The cables do not spread combustion at group installation of cable lines in the absence of mechanical effects on the cable and keep working when exposed by flame on the cable not less than 180 minutes.

The cables are designed for wiring and emergency power circuits of equipment (current collectors), in residential and public buildings, in the surgical departments of hospitals, in the office premises, equipped with computer and micro processor devices, spectacular complexes and sports facilities, as well as in other objects with the high demand of fire safety.

The class of fire hazard of the cables according to GOST 31565 П1б.1.2.1.2.

STRUCTURE

Conductor

Copper of round form, single-wire with the cross-section from 1.5 to 16 mm2 of the 1 class or multi-wire core with the cross-section from 10 to 16 mm2 of the 2 class according to GOST 22483.

From 1 to 5 conductors.

Insulation

Ceramic forming silicone rubber.

Core arrangement

Insulated conductors of 2-5 core cables are twisted.

Inner sheath

PVC-compound of low toxicity.

Screen

For cables of types RVGEng(A)-FRLSTx is made of copper tapes.

Over sheath

PVC-compound of low toxicity

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / With low smoke and gas emission (-LS) / Low toxicity (-LTx) / Fireproof (-FR) / Shielded
Insulation
Copper
Shell
Silicon rubber
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
2х1,5ок(N)-0,66  11,5 231
2х2,5ок(N)-0,66  12,3 272
2х4ок(N)-0,66  13,6 344
2х6ок(N)-0,66  14,6 412
3х1,5ок(N,PE)-0,66  11,9 254
3х2,5ок(N,PE)-0,66  12,8 304
3х4ок(N,PE)-0,66  14,2 391
3х6ок(N,PE)-0,66  15,3 477
4х1,5ок(N)-0,66 12,7 288
4х2,5ок(N)-0,66  13,6 349
4х4ок(N)-0,66  15,2 456
4х6ок(N)-0,66  16,6 577
5х1,5ок(N,PE)-0,66  13,5 329
5х2,5ок(N,PE)-0,66  14,5 403
5х4ок(N,PE)-0,66 16,6 545
5х6ок(N,PE)-0,66 18,3 699
2х1,5ок(N)-1  12,3 259
2х2,5ок(N)-1 13,1 301
2х4ок(N)-1  14,4 376
2х6ок(N)-1  15,4 446
3х1,5ок(N,PE)-1  12,8 284
3х2,5ок(N,PE)-1  13,6 336
3х4ок(N,PE)-1  15,1 426
3х6ок(N,PE)-1 16,3 524
4х1,5ок(N)-1 13,7 323
4х2,5ок(N)-1  14,6 385
4х4ок(N)-1  16,4 506
4х6ок(N)-1  17,6 621
5х1,5ок(N,PE)-1 14,6 370
5х2,5ок(N,PE)-1  15,6 445
5х4ок(N,PE)-1  17,6 592
5х6ок(N,PE)-1  19,4 749