Products

Search by features


VVG, AVVG, VBV, АVBV, according to specifications 16.K71-359-2005
specifications 16.K71-359-2005

Conductor

Copper or aluminum, single-wire or multi-wire core, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

Is made of PVC-compound (color coded conductor)

Core arrangement

Insulated conductors of three-core cables are twisted in a cable core.

Inner sheath

It is made by extrusion with PVC-compound or chalk-filled non-cured rubber with the filling of outer gaps between insulated conductors. It is possible to fill the outer gaps between circular insulated cores with the bundles of non hygroscopic fiber or polymer materials with the lapping of fastening tape, on the top of which the expressional inner sheath is laid. It is allowed to wrap the cable core with the layer of tapes of polymer material, compatible with the materials of insulation and over sheath.

Taping

It is made of tape or tapes of conductive paper or conductive, synthetic tape or of tapes of non-woven fabric.

Screen

Is made of copper wires and a spirally imposed copper tape. It is allowed the taping of the screen with copper tapes.

Separating layer

Of polymer tape or non-woven fabric.

Bedding

For types VBV, АVBV is made of PVC-compound.

Cable armoring

It is laid helically with two steel, galvanized tapes. It is possible to overlap or longitudinally with PET or polypropylene tape.

Over sheath

PVC-compound.

The cables are designed for transmission and distribution of electric power at the stationary installation on the nominal alternating voltage 6 kV of frequency 50 Hz for networks with the earthed and insulated neutral.

They can be laid in dry soils (sand, sandy-clay and normal soil with a moisture content of 14%).

The climate modification УХЛ and T, categories of location 1 and 5 according to GOST 15150/ including installation in the ground.

The class of fire hazard of the cables according to GOST 31565 01.8.2.5.4.

Nominal voltage, kV 6
Ambient temperature during cable operation, °С from – 50 to + 50
Minimum bending radius, diameters of cable for multi-wire 12
for single-wire 15
at installation with usage of a special template 7,5
The cables are laid at temperature (without preheat), °С, not below - 15

TABLE 1

Current-carrying conductors are manufactured single- or multi-wire according to the table

Type of current-carrying conductor Nominal cross-section of conductor, mm2
circular sector-shaped
single- multi- single- multi-
wire wire wire wire
Copper for single-wire cables 16 - 50 16 - 800
for multi-wire cables 16 - 240 50 - 240
Aluminum for single-wire cables 16 - 240 25 - 800
for multi-wire cables 16 - 240 25 - 240 35 - 240 35 - 240

 

TABLE 2

Minimum nominal cross-section of a copper screen

Designation Nominal cross-section, mm2
Main conductor 16-120 150-300 400 и более
Screen 16 25 35
You can create an application yourself. Using the "Add brand manually" button, select the required cable brand and specify the quantity. After submitting the form, our managers will contact you and clarify the details of the order.

« * »  - required fields


FULL NAME:*

E-mail:*

Telephone:*

A comment:

Attach file