Products

Search by features


ВВГ-П (VVG-P)

ВВГ-П (VVG-P)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
For a single pad
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-P
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) width height Calculated weight of cable, kg/km  
2х1,5ож(N)-0,66 6,7 4,4 55
2х2,5ож(N)-0,66 7,5 4,7 76
2х4ож(N)-0,66 8,8 5,4 112
2х6ож(N)-0,66 9,8 5,9 152
2х10ож(N)-0,66 12,4 7,3 247
2х16ож(N)-0,66 14,2 8,2 360
3х1,5ож(N,PE)-0,66 9,1 4,4 79
3х2,5ож(N,PE)-0,66 10,2 4,7 110
3х4ож(N,PE)-0,66 12,2 5,4 163
3х6ож(N,PE)-0,66 13,9 5,9 227
3х10ож(N,PE)-0,66 17,5 7,3 363
3х16ож(N,PE)-0,66 20,2 8,2 531
2х1,5ож(N)-1 7,5 4,8 63
2х2,5ож(N)-1 8,3 5,1 84
2х4ож(N)-1 10,0 6,0 126
2х6ож(N)-1 11,0 6,5 167
2х10ож(N)-1 12,8 7,5 253
2х16ож(N)-1 15,2 9,0 384
3х1,5ож(N,PE)-1 10,3 4,8 89
3х2,5ож(N,PE)-1 11,4 5,1 121
3х4ож(N,PE)-1 14,0 6,0 183
3х6ож(N,PE)-1 15,7 6,5 250
3х10ож(N,PE)-1 18,1 7,5 372
3х16ож(N,PE)-1 21,4 9,0 564

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary installations on a nominal alternating voltage 0,66; 1 and 3 kV, 50 Hz. Cables are flame retardant in single installation.

The class of fire hazard of the cables is according to GOST 31565 01.8.2.5.4.

STRUCTURE

Conductor

Copper core, single-wire or multiwire, circular or sector-shaped form of the 1 class according to GOST 22483.

Insulation

PVC- compound (color coded conductor).

Core arrangement

2 or 3 insulated conductors are arranged in one plane.

Cable sheath or jacket

PVC compound.

By category
Force cables
Voltage
660 / 1000
In execution
For a single pad
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
VVG-P
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) width height Calculated weight of cable, kg/km  
2х1,5ож(N)-0,66 6,7 4,4 55
2х2,5ож(N)-0,66 7,5 4,7 76
2х4ож(N)-0,66 8,8 5,4 112
2х6ож(N)-0,66 9,8 5,9 152
2х10ож(N)-0,66 12,4 7,3 247
2х16ож(N)-0,66 14,2 8,2 360
3х1,5ож(N,PE)-0,66 9,1 4,4 79
3х2,5ож(N,PE)-0,66 10,2 4,7 110
3х4ож(N,PE)-0,66 12,2 5,4 163
3х6ож(N,PE)-0,66 13,9 5,9 227
3х10ож(N,PE)-0,66 17,5 7,3 363
3х16ож(N,PE)-0,66 20,2 8,2 531
2х1,5ож(N)-1 7,5 4,8 63
2х2,5ож(N)-1 8,3 5,1 84
2х4ож(N)-1 10,0 6,0 126
2х6ож(N)-1 11,0 6,5 167
2х10ож(N)-1 12,8 7,5 253
2х16ож(N)-1 15,2 9,0 384
3х1,5ож(N,PE)-1 10,3 4,8 89
3х2,5ож(N,PE)-1 11,4 5,1 121
3х4ож(N,PE)-1 14,0 6,0 183
3х6ож(N,PE)-1 15,7 6,5 250
3х10ож(N,PE)-1 18,1 7,5 372
3х16ож(N,PE)-1 21,4 9,0 564