Search by features
-
Power cables of nominal voltage up to 3kv
- Power cables for single installation
- VVG, AVVG, VVGE, AVVGE, VBShV, AVBShV, according to specification 16-705.4992010
- VVG-P, AVVG-P, according to specification 16-705.499-2010
- VVG, AVVG, VVGz, AVVGz, VBbShV, AVBbShV, VVG-P, AVVG-P, according to GOST 16442-80
- VVG-KhL, AVVG-KhL, VVGE-KhL, AVVGE-KhL, VBShv-KhL, AVBShv-KhL, VVG-P-KhL, AVVG-P-KhL
- VVGg-KhL, AVVGg-KhL, VVGEg-KhL, AVVGEg-KhL, VBShvg-KhL, AVBShvg-KhL, according to specification 16.K121-017-2011
- VBaShv-KhL, AVBaShv-KhL, VKaShv-KhL, VKShv-KhL, AVKShv-KhL, AVKaShv-KhL, according to specification 16.K121-017-2011
- PvVG, APvVG, PvVGE, APvVGE, PvBShv, APvBShv, PvVG-P, APvVG-P, PvBShP, APvBShP, according to specification 16-705.499-2010
- PvVG-KhL, APvVG-KhL, PvVGE-KhL, APvVGE -KhL, PvVG-P-KhL, APvVG-P-KhL, PVBShv-KhL, APVBShv-KhL, PVBaShv-KhL, APVBaShv-KhL, PvKShv-KhL, APvKShv-KhL, PvKaShv-KhL, APvKaShv-KhL, according to specification 16.K121-017-2011
- ПвВГ-ХЛ (PvVG-KhL)
- АПвВГ-ХЛ (APvVG-KhL)
- ПвВГЭ-ХЛ (PvVGE-KhL)
- АПвВГЭ-ХЛ (APvVGE-KhL)
- ПвВГ-П-ХЛ (PvVG-P-KhL)
- АПвВГ-П-ХЛ (APvVG-P-KhL)
- ПвБШв-ХЛ (PvBShv-KhL)
- АПвБШв-ХЛ (APvBShv-KhL)
- ПвБаШв-ХЛ (PvBaShv-KhL)
- АПвБаШв-ХЛ (APvBaShv-KhL)
- ПвКШв-ХЛ (PvKShv-KhL)
- АПвКШв-ХЛ (APvKShv-KhL)
- ПвКаШв-ХЛ (PvKaShv-KhL)
- АПвКаШв-ХЛ (APvKaShv-KhL)
- NYM-J, NYM-O according to specifications 3521-002-53972660-2007
- NY(F)2Y-J
- Power cables flame retardant at group installation (modification "flame retardant")
- Power cables with plastic insulation flame retardant at group installation in cold-resistant modification
- VVGng(A)-KhL, AVVGng(A)-KhL, VVGEng(A)-KhL, AVVGEng(A)-KhL, VBShvng(A)–KhL, АVBShvng(A), VVG-Png(A)-KhL, AVVG-Png(A)-KhL, according to specifications 16.K121-017-2011
- VBAShvng (A)-KhL, AVBAShvng(A)-KhL, VKShvng(A)-KhL, AVKShvng(A)-KhL, VKaShvng(A)-KhL, AVKaShvng(A)-KhL, according to specifications 16.K121-017-2011
- PvVGng(A)-KhL, APvVGng(A)-KhL, PvVG-Png(A)-KhL, APvVG-Png(A)-KhL, PvVGEng(A)-KhL, APvVGEng(A)-KhL, PvBShvng(A)-KhL, APvBShvng(A)-KhL, PvBaShvng(A)-KhL, APvBaShvng(A)-KhL, PvKShvng(A)-KhL, APvKShvng(A)-KhL, PvKaShvng(A)-KhL, APvKaShvng(A)-KhL
- ПвВГнг(А)-ХЛ (PvVGng(A)-KhL)
- АПвВГнг(А)-ХЛ (APvVGng(A)-KhL)
- ПвВГ-Пнг(А)-ХЛ (PvVG-Png(A)-KhL)
- АПвВГ-Пнг(А)-ХЛ (APvVG-Png(A)-KhL)
- ПвВГЭнг(А)-ХЛ (PvVGEng(A)-KhL)
- АПвВГЭнг(А)-ХЛ (APvVGEng(A)-KhL)
- ПвБШвнг(А)-ХЛ (PvBShvng(A)-KhL)
- АПвБШвнг(А)-ХЛ (APvBShvng(A)-KhL)
- ПвБаШвнг(А)-ХЛ (PvBaShvng(A)-KhL)
- АПвБаШвнг(А)-ХЛ (APvBaShvng(A)-KhL)
- ПвКШвнг(А)-ХЛ (PvKShvng(A)-KhL)
- АПвКШвнг(А)-ХЛ (APvKShvng(A)-KhL)
- ПвКаШвнг(А)-ХЛ (PvKaShvng(A)-KhL)
- АПвКаШвнг(А)-ХЛ (APvKaShvng(A)-KhL)
- VGng (A)-KhL, AVVGng (A)-KhL, VVGEng (A)-KhL, AVVGEng (A)-KhL, VBShVng (A)–KhL, AVBShVng (A)–KhL, VBaShVng (A)–KhL, AVBaShVng (A)–KhL, VeBShvng (A)–KhL, AVeBShvng (A)–KhL, VeBShvng (A)–KhL, АVeBShvng (A)–KhL, according to specifications 16.K121-027-20133
- ВВГнг(А)-ХЛ (VVGng(A)-KhL)
- АВВГнг(А)-ХЛ (AVVGng(A)-KhL)
- ВВГЭнг(А)-ХЛ (VVGEng(A)-KhL)
- АВВГЭнг(А)-ХЛ (AVVGEng(A)-KhL)
- ВБШвнг(А)-ХЛ (VBShVng(A)–KhL)
- АВБШвнг(А)-ХЛ (AVBShVng(A)–KhL)
- ВБаШвнг(А)-ХЛ (VBaShVng(A)–KhL)
- АВБаШвнг(А)-ХЛ (AVBaShVng(A)–KhL)
- ВЭБШвнг(А)-ХЛ (VEBShvng(A)–KhL)
- АВЭБШвнг(А)-ХЛ (AVEBShvng(A)–KhL)
- ВЭБаШвнг(А)-ХЛ (VEBaShvng(A)–KhL)
- АВЭБаШвнг(А)-ХЛ (АVEBaShvng(A)–KhL)
- VVGgng(A)-KhL, AVVGgng(A)-KhL, VVGEgng(A)-KhL, AVVGEgng(A)-KhL, VBShVgng(A)–KhL, AVBShVgng(A)–KhL, VBaShVgng(A)–KhL, AVBaShVgng(A)–KhL, VeBShvgng(A)–KhL, AVeBShvgng(A)–KhL, VeBShvgng(A)–KhL, АVeBShvgng(A)–KhL
- ВВГгнг(А)-ХЛ (VVGgng(A)-KhL)
- АВВГгнг(А)-ХЛ (AVVGgng(A)-KhL)
- ВВГЭгнг(А)-ХЛ (VVGEgng(A)-KhL)
- АВВГЭгнг(А)-ХЛ (AVVGEgng(A)-KhL)
- ВБШвгнг(А)-ХЛ (VBShvgng(A)-KhL)
- АВБШвгнг(А)-ХЛ (AVBShvgng(A)-KhL)
- ВБаШвгнг(А)-ХЛ (VBaShvgng(A)-KhL)
- АВБаШвгнг(А)-ХЛ (AVBaShvgng(A)-KhL)
- ВЭБШвгнг(А)-ХЛ (VEBShvgng(A)-KhL)
- АВЭБШвгнг(А)-ХЛ (AVEBShvgng(A)-KhL)
- ВЭБаШвгнг(А)-ХЛ (VEBaShvgng(A)-KhL)
- АВЭБаШвгнг(А)-ХЛ (АVEBaShvgng(A)-KhL)
- VVG-Png(A)-Kh-L, AVVG-Png(A)-Kh-L, VVG-Pgng(A)-Kh-L, AVVG-Pgng(A)-Kh-L, according to specifications 16.K121-027-2013
- Power cables with plastic insulation, flame retardant at group installation with low smoke- and gas emission
- VVGng(A)-LS, AVVGng(A)-LS, VVGEng(A)-LS, AVVGEng(A)-LS, VBShvng(A)-LS, AVBShvng(A)-LS, according to specifications 16 .K71-310-2001
- VVG-Png(A)-LS, AVVG-Png(A)-LS, according to specifications respectively, 16.K71-310-2001
- VVGng(A)-LS, AVVGng(A)-LS, VVGEng(A)-LS, AVVGEng(A)-LS, VBShvng(A)-LS, AVBShvng(A)-LS, according to specifications 16 .K121-018-2011
- VVG-Png(A)-LS, AVVG-Png(A)-LS, according to specifications 16.K121-018-2011
- PvVGng(A)-LS, APvVGng(A)-LS, PvVGЕng(A)-LS, APvVGЕng(A)-LS, PvBShvng(A)-LS, АPvBShvng(A)-LS, according to specifications 16 .K121-018-2011
- PvVGng(A)-LS, PvVGЕng(A)-LS,PvBShvng(A)-LS according to specifications 16.K71-480-2015
- Power cables with xlpe insulation, flame retardant at group installation with low smoke- and gas emission
- Power cables, flame retardant at group installation and not emitting corrosive active gaseous products at burning and smouldering (modification "flame retardant – halogen-free")
- PPGng(A)-HF, PPGEng(A)-HF, PBPng(A)-HF, PPGgng(A)-HF, PPGEgng(A)-HF, PBPgng(A)-HF, according to specifications 16.K121-023-2011
- PvPGng(A)-HF, PvPGEng(A)-HF, according to specifications 16.K71-341-2004
- PPGng(A)-HF, PPGЕng(A)-HF, PBPng(A)-HF, PvPGng(A)-HF, according to specifications 16.K71-304-2001
- PvPGng(A)-HF, PvPGEng(A)-HF, PvBPng(A)-HF, according to specifications 16.K71-480-2015
- Power cables, fire-resisting, flame retardant at group installation, with low smoke- and gas emission (modification "flame retardant – "fire-resistant low smoke")
- VVGng(A)-FRLS, VVGЕng(A)-FRLS, VBShvng(A)-FRLS, VVG-Png(A)-FRLS, according to specifications 16.K121-022-2011
- VVGng(A)-FRLS, VVGЕng(A)-FRLS, according to specifications 16.K71-337-2004
- PvVGng(A)-FRLS, PvVGEng(A)-FRLS, PvBShvng(A)-FRLS, according to specifications 16.K121-022-2011
- PvVGng(A)-FRLS, according to specifications 16.K71-341-2004
- RVGng(A)-FRLS, RVG-Рng(A)-FRLS, RVGЕng(A)-FRLS, according to specifications 16.K121-026-2013
- PvVGng(A)-FRLS, PvVGEng(A)-FRLS, PvBShvng(A)-FRLS according to specifications 16.K71-480-2015
- Low-toxic power cables flame retardant at group installation with low smokeand gas emission
- Power cables fire-resistant flame retardant at group installation, which do not emmit toxic corrosive active gaseous products while burning and smouldering (modification "flame retardant – fire-resistant halogen-free")
- PvPGng(A)-FRHF, PvPGЕng(A)-FRHF, according to specifications 16.K71-341-2004
- PvPGng-FRHF, PvPGEng-FRHF, PvBPng-FRHF, PvPGgng-FRHF, PvPGEgng-FRHF, PvBPgng-FRHF, according to specifications 16.K121-023-2011
- PPGng(A)-FRHF, PPGЕng(A)-FRHF, PBPng(A)-FRHF, according to specifications 16.K71-341-2004
- PPGng(A)-FRHF, PPGЕng(A)-FRHF, PvPGng(A)-FRHF, PvPGEng(A)-FRHF, according to specifications 16.K71-339-2014
- RPGng(A)-FRHF, RPGEng(A)-FRHF, RPG-Png(A)-FRHF, according to specifications 16.K121-026-2013
- PvPGng(A)-FRHF, PvPGEng(A)-FRHF, PvBPng(A)-FRHF according to specifications16.K71-480-2015
- Power cables fire-resisting with plastic insulation flame retardant at group installation in cold-resistant modification with the temperature of cable installation up to -30 degrees below zero
- Power cables for single installation
-
Power cables for rated voltage up to 6 kV
- VVG, AVVG, VVGg, AVVGg, VBV, AVBV, VBVg, AVBVg, according to specifications 16.K121-028-2013
- PvPGng(A)-HF, PvPGng(A)-HF according to specifications 16.K71-480-2015
- KVEBShv, KVEBShv(u), according to specifications 16.K121-024-2013
- VVG, AVVG, VBV, АVBV, according to specifications 16.K71-359-2005
- KVEBShvng(A), KVEBShv(u)ng(A), according to specifications 16. K121-024-2013
- VVGng(A), AVVGng(A), VVGgng(A), AVVGgng(A), VBVng(A), AVBVng(A), VBVgng(A), AVBVgng(A), according to specifications 16.K121-028-2013
- VBVng(A), AVBVng(A), according to specifications 16.K71-359-2005
- KVEBShv-KhL, KVEBShv(u)-KhL, according to specifications 16.K121-024-2013
- KVEBShvng(A)KhL, KVEBShv(u)ng(A)KhL, according to specifications 16.K121-024-2013
- VVGng(A)-LS, AVVGng(A)-LS, VVGgng(A)-LS, АVVGgng(A)-LS, VBVng(A)-LS, AVBVng(A)-LS, VBVgng(A)-LS, AVBVgng(A)-LS, according to specifications 16.K121-028-2013
- KVEBShvng(A)-FRLS, KVEBShv(u)ng(A)-FRLS according to specifications 16.K121-024-2013
- KVEBShvng(A)-FRKhL, KVEBShv(u)ng(A)-FRKhL according to specifications 16.K121-024-2013
- PvVGng(A)-LS, PvBShvng(A)-LS according to specifications 16.K71-480-2015
-
Control cables
- KVVG, KVVGz, KVVGE, KVBbShv, according to GOST 1508-78
- KVVGng(A), KVVGzng(A), KVVGЕng(A), KVBbShvng(A), KVBbShvzng(A), according to specifications 3563-004-53972660-2008
- KVVGng(A)-KhL, KVVGzng(A)-KhL, KVVGЕng(A)-KhL, KVBbShvng(A)-KhL, KVVG-Png(A)-KhL, according to specifications 16.K121-012-2013
- KVVGng(A)-KhL, KVVGЕng(A)-KhL, KVBbShvng(A)-KhL, KVVGgng(A)-KhL, KVVGЕgng(A)-KhL, KVBbShvgng(A)-KhL, according to specifications 16.K121-030-2013
- KVVGng(A)- FRLSLTx, KVVGЕng(A)- FRLSLTx, KVBbShvng(A)- FRLSLTx according to specifications 3563-010-53972660-2010
- KVVGng(A)-LS, KVVGEng(A)-LS, according to specifications 16.K71-310-2001
- KVVGng(A)-LS, KVVGzng(A)-LS, KVVGЕng(A)-LS, KVBbShvng(A)-LS, KVVG-Png(A)-LS, according to specifications 3563-010-53972660-2010
- KPPGng(A)-HF, KPPGЕng(A)-HF, KPBPng(A)-HF, according to specifications 16.K71-304-2001
- KPPGng(A)-HF, KPPGЕng(A)-HF, KPBbPng(A)-HF, according to specifications 16.K121-029-2013
- KVVGng(A)-FRLS, KVVGЕng(A)-FRLS, according to specifications 16.K71-337-2004
- KVVGng(A)-FRLS, KVVGЕng(A)-FRLS, KVBbShvng(A)-FRLS, according to specifications 3563-010-53972660-2010
- KPPGng(A)-FRHF, KPPGЕng(A)-FRHF, according to specifications 16.K71-339-2004
- KPPGng(A)-FRHF, KPPGЕng(A)-FRHF, KPBbPng(A)-FRHF, according to specifications 16.K121-029-2014
- KPBPng(A)- FRHF, KPvBPng(A)-FRHF according to specifications 16.K71-480-2015
- KVVGng(A)-FRKhL, KVVGЕng(A)-FRKhL, KVBbShvng(A)-FRKhL, according to specifications 16.K121-030-2013
- KPBShvng(A)-FRLS, KPvBShvng(A)-FRLS according to specifications 16.K71-480-2015
- KPBPng(A)- HF, KPvBPng(A)- HF according to specifications 16.K71-480-2015
- KPBShvng(A)-LS, KPvBShvng(A)-LS according to specifications 16.К71-480-2015
- KVVGng(A)- LSLTx, KVVGzng(A)- LSLTx, KVVGЕng(A)- LSLTx, KVBbShvng(A)- LSLTx, KVVG-Png(A)- LSLTx according to specifications 3563-010-53972660-2010
- Wires, cords and connecting cables
-
Wires and cables for electrical units
- PuV, PuGV, PuVV, PuGVV, KuVV, KuGVV, according to specifications 16-705.501-2010
- PV1, PV1-KhL, PV2, PV2-KhL, PV3, PV3-KhL, PV4, PV4-KhL, PPV, PPV-KhL, АPV, АPV-KhL, according to GOST 6323-79
- PuVng(A)-LS, PuGVng(A)-LS, PuVVng(A)-LS, PuGVVng(A)-LS, KuVVng(A)-LS, KuGVVng(A)-LS, according to specifications 16-705.502-2011
- KuRVng(A)-FRLS, KuGRVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuREVng(A)-FRLS, KuGREVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuRKVng(A)-FRLS, KuGRKVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuREVKVng(A)-FRLS, KuGREVKVng(A)-FRLS, according to specifications 16-K121-025-2013
- KuRPng(A)-FRHF, KuGRPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuREPng(A)-FRHF, KuGREPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuRKPng(A)-FRHF, KuGRKPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuREPKPng(A)-FRHF, KuREPKPng(A)-FRHF, according to specifications 16.K121-025-2013
- KuRVng(A)-FRLSTx, KuGRVng(A)-FRLSTx, according to specifications 16-K121-025-2013
- KuRKVng(A)-FRLSTx, KuGRKVng(A)-FRLSTx, according to specifications 16-K121-025-2013
- KuREVng(A)-FRLSTx, KuREVng(A)-FRLSTx, according to specifications 16-K121-025-2013
-
Cables for Fire Alarm Systems
- КPSVVng(А)-LS, КPSVVGng(А)-LS, КPSVEVng(А)-LS, КPSVEVGng(А)-LS, КPSVEEVng(А)-LS, КPSVEEVGng(А)-LS, according to specifications 16.K121-020-2011
- КPSng(А)-FRLS, КPSGng(А)-FRLS, КPSEng(А)-FRLS, КPSEGng(А)-FRLS, КPSEEng(А)-FRLS, КPSEEGng(А)-FRLS, according to specifications 16.K121-021-2011
- KPSng(A)-FRHF, KPSGng(A)-FRHF, KPSEng(A)-FRHF, KPSEGng(A)-FRHF, KPSEEng(A)-FRHF, KPSЕEGng(A)-FRHF, according to specifications 16.K121-021-2011
- KPSSng(A)-FRLS, KPSSGng(A)-FRLS, KPSESng(A)-FRLS, KPSESGng(A)-FRLS, according to specifications 16.K121-021-2011
- KPSSng(A)-FRHF, KPSSGng(A)-FRHF, KPSESng(A)-FRHF, KPSESGng(A)-FRHF, according to specifications 16.K121-021-2011
- KPSSng(A)-FRLSLTx, KPSSGng(A)-FRLSLTx, KPSЕSng(A)-FRLSLTx,KPSЕSGng(A)-FRLSLTx according to specifications 16.K121-021-2011
-
Cables for monitoring and control circuits
- KUGVVng(A)-LS, KUGVEVng(A)-LS, KUGVVEng(A)-LS, according to specifications 16.K71-310-2001
- KUGVVng(A)-FRLS, KUGVEVng(A)-FRLS, KUGVVЕng(A)-LS, according to specifications 16.K71-337-2004
- KUPPng(A)-HF, KUPPlng(A)-HF, according to specifications 3561-411-00217053-2009
- KUPPmng(A)-HF, KUPPmng(A)-FRHF, KUPEfPmng(A)-HF, KUPEfPmng(A)-FRHF, according to specifications 3561-441-00217053-2012
- KUPPng(A)-FRHF, KUPPlng(A)-FRHF, according to specifications 3561-442-00217053-2012
- KUGPvEPvng(A)-HF-LOCA, KUGPvEPvng(A)-HF-T-LOCA, KUGPvEPvng(A)-FRHF-LOCA, KUGPvEPvng(A)-FRHF-T-LOCA, KUGPvEPvng(A)-HF, KUGPvEPvng(A)-HF-T, KUGPvEPvng(A)-FRHF, KUGPvEPvng(A)-FRHF-T according to specifications 16.К71-451-2012
- КУГПвЭПвнг(А)-HF-LOCA (KUGPvEPvng(A)-HF-LOCA)
- КУГПвЭПвнг(А)-HF (KUGPvEPvng(A)-HF)
- КУГПвЭПвнг(А)-HF-Т-LOCA (KUGPvEPvng(A)-HF-T-LOCA)
- КУГПвЭПвнг(А)-HF-Т (KUGPvEPvng(A)-HF-T)
- КУГПвЭПвнг(А)-FRHF-LOCA (KUGPvEPvng(A)-FRHF-LOCA)
- КУГПвЭПвнг(А)-FRHF (KUGPvEPvng(A)-FRHF)
- КУГПвЭПвнг(А)-FRHF-Т-LOCA (KUGPvEPvng(A)-FRHF-T-LOCA)
- КУГПвЭПвнг(А)-FRHF-Т (KUGPvEPvng(A)-FRHF-T)
- Small-size cables
-
Cables for control systems and alarm
- KPEPng(A)-HF, KGPEPng(A)-HF, KUGPPng(A)-HF, KUGPPEng(A)-HF, KUGPPEPng(A)-HF, KUGPEPng(A)-HF, KUGEPPng(A)-HF, KUGEPPEng(A)-HF, KUGEPPEPng(A)-HF, according to specifications 16.K71-338-2004
- KPEPng(A)-FRHF, KGPEPng(A)-FRHF, KUGPPng(A)-FRHF, KUGPPЕng(A)-FRHF, KUGPPЕРng(A)-FRHF, KUGPЕРng(A)-FRHF, KUGЕРРng(A)-FRHF, KUGЕРРЕng(A)-FRHF, KUGЕРРЕРng(A)-FRHF, according to specifications 16.K71-338-2004
- КПЭПнг(А)-FRHF (KPEPng(A)-FRHF)
- КГПЭПнг(А)-FRHF (KGPEPng(A)-FRHF)
- КУГППнг(А)-FRHF (KUGPPng(A)-FRHF)
- КУГППЭнг(А)-FRHF (KUGPPЕng(A)-FRHF)
- КУГППЭПнг(А)-FRHF (KUGPPЕРng(A)-FRHF)
- КУГПЭПнг(А)-FRHF (KUGPЕРng(A)-FRHF)
- КУГЭППнг(А)-FRHF (KUGЕРРng(A)-FRHF)
- КУГЭППЭнг(А)-FRHF (KUGЕРРЕng(A)-FRHF)
- КУГЭППЭПнг(А)-FRHF (KUGЕРРЕРng(A)-FRHF)
-
Telephone cables
- TVBPng(A)-HF – Russian analogue of J-2YF(St)H… Bd, А-2YF(L)H..BD, TVBPBbPng(A)-HF – Russian analogue of J-2YF(St)BH according to Specification 16.K71-468-2015
- TVBVng(A)-LS – Russian analogue of J-2YF(St)Y… Bd, А-2YF(L)Y..BD Flame Retardant Low Smoke, TVBVBbShvng(A)-LS – Russian analogue of J-2YF(St)BY Flame Retardant Low Smoke according to Specification 16.K71-468-2015
КПЭПнг(А)-HF (KPEPng(A)-HF)
- By category
- Cables for control and signaling
- Voltage
- 250 / 380 / 1000
- In execution
- Flame retardant (-ng(А)) / Halogen free (-HF) / Shielded
- Insulation
- Copper
- Shell
- Polymer composition
- Core material
- Polymer composition
- Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPEPng(A)-HF Number of conductors, nominal cross-section (mm2) Calculated diameter of cable, mm Calculated weight of cable, kg/km 1х2х0,5 5,9 49 2х2х0,5 7,0 66 4х2х0,5 8,3 94 6х2х0,5 9,1 117 8х2х0,5 9,8 137 10х2х0,5 11,1 165 12х2х0,5 12,5 193 14х2х0,5 12,5 207 16х2х0,5 13,7 228 20х2х0,5 14,5 264 24х2х0,5 15,9 306 30х2х0,5 17,2 364 40х2х0,5 19,3 469 50х2х0,5 21,8 571 60х2х0,5 23,2 660 80х2х0,5 26,3 861 100х2х0,5 29,2 1069 1х2х0,6 6,1 53 2х2х0,6 7,2 73 4х2х0,6 8,7 105 6х2х0,6 9,6 133 8х2х0,6 10,3 158 10х2х0,6 11,7 191 12х2х0,6 13,2 223 14х2х0,6 13,8 242 16х2х0,6 14,7 267 20х2х0,6 16,2 312 24х2х0,6 18,0 363 30х2х0,6 18,2 451 40х2х0,6 20,5 561 50х2х0,6 23,1 686 60х2х0,6 24,7 820 80х2х0,6 28,0 1041 100х2х0,6 31,2 1293 1х2х0,8 6,5 61 2х2х0,8 7,8 89 4х2х0,8 9,5 133 6х2х0,8 10,5 171 8х2х0,8 11,2 207 10х2х0,8 12,9 252 12х2х0,8 14,6 297 14х2х0,8 14,6 325 16х2х0,8 15,9 361 20х2х0,8 17,0 425 24х2х0,8 18,6 499 30х2х0,8 20,3 620 40х2х0,8 22,9 781 50х2х0,8 25,8 984 60х2х0,8 27,6 1148 80х2х0,8 31,7 1501 100х2х0,8 35,9 1916 1х2х1,13 7,1 82 2х2х1,13 9,3 130 4х2х1,13 11,5 205 6х2х1,13 12,9 272 8х2х1,13 13,9 336 10х2х1,13 16,1 411 12х2х1,13 18,7 505 14х2х1,13 18,7 558 16х2х1,13 19,7 623 20х2х1,13 21,1 742 24х2х1,13 23,7 896 30х2х1,13 26,4 1084 40х2х1,13 30,1 1409 50х2х1,13 33,1 1734 60х2х1,13 36,8 2122 80х2х1,13 41,7 2729 100х2х1,13 45,9 3337 1х2х1,38 7,49 99 2х2х1,38 10,0 163 4х2х1,38 12,4 266 6х2х1,38 14,0 361 8х2х1,38 15,1 451 10х2х1,38 17,6 555 12х2х1,38 20,5 678 14х2х1,38 20,5 758 16х2х1,38 21,6 850 20х2х1,38 23,1 1021 24х2х1,38 26,0 1230 30х2х1,38 29,2 1527 40х2х1,38 33,1 1963 50х2х1,38 37,5 2510 60х2х1,38 40,5 2949 80х2х1,38 45,9 3821 100х2х1,38 50,7 4695
SCOPE AND PURPOSE
The cables are designed for transmission OF ELECTRIC SIGNALS and distribution of electric energy in control circuits, alarm, communications, and unit connections of voltage 250, 380 and 1000V of alternating current of frequency up to 200 kHz or at voltage correspondingly 350, 750 and 1500V of direct current.
The cables are manufactured for general industrial use and nuclear power stations at usage out of under containment zone of NPP.
The climate modification B, categories of location – 5, according to GOST 15150-69.
The class of fire hazard of the cables according to GOST 31565- 2012 П1б.8.1.2.1.
STRUCTURE
Current-carrying conductor
Copper, single-wire of the 1 class according to GOST 22483- 2012.
Insulation
Halogen-free polymer composition.
Twisting in pairs.
For cables with pair twisting the insulated conductors are twisted in pairs.
Separating layer
Taping with PET–E film.
Screen
Common screen in the form of foil, composite flexible material under the sheath, copper galvanized contact wire is laid under the screen.
Over sheath
Halogen-free polymer composition.
- By category
- Cables for control and signaling
- Voltage
- 250 / 380 / 1000
- In execution
- Flame retardant (-ng(А)) / Halogen free (-HF) / Shielded
- Insulation
- Copper
- Shell
- Polymer composition
- Core material
- Polymer composition
- Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KPEPng(A)-HF Number of conductors, nominal cross-section (mm2) Calculated diameter of cable, mm Calculated weight of cable, kg/km 1х2х0,5 5,9 49 2х2х0,5 7,0 66 4х2х0,5 8,3 94 6х2х0,5 9,1 117 8х2х0,5 9,8 137 10х2х0,5 11,1 165 12х2х0,5 12,5 193 14х2х0,5 12,5 207 16х2х0,5 13,7 228 20х2х0,5 14,5 264 24х2х0,5 15,9 306 30х2х0,5 17,2 364 40х2х0,5 19,3 469 50х2х0,5 21,8 571 60х2х0,5 23,2 660 80х2х0,5 26,3 861 100х2х0,5 29,2 1069 1х2х0,6 6,1 53 2х2х0,6 7,2 73 4х2х0,6 8,7 105 6х2х0,6 9,6 133 8х2х0,6 10,3 158 10х2х0,6 11,7 191 12х2х0,6 13,2 223 14х2х0,6 13,8 242 16х2х0,6 14,7 267 20х2х0,6 16,2 312 24х2х0,6 18,0 363 30х2х0,6 18,2 451 40х2х0,6 20,5 561 50х2х0,6 23,1 686 60х2х0,6 24,7 820 80х2х0,6 28,0 1041 100х2х0,6 31,2 1293 1х2х0,8 6,5 61 2х2х0,8 7,8 89 4х2х0,8 9,5 133 6х2х0,8 10,5 171 8х2х0,8 11,2 207 10х2х0,8 12,9 252 12х2х0,8 14,6 297 14х2х0,8 14,6 325 16х2х0,8 15,9 361 20х2х0,8 17,0 425 24х2х0,8 18,6 499 30х2х0,8 20,3 620 40х2х0,8 22,9 781 50х2х0,8 25,8 984 60х2х0,8 27,6 1148 80х2х0,8 31,7 1501 100х2х0,8 35,9 1916 1х2х1,13 7,1 82 2х2х1,13 9,3 130 4х2х1,13 11,5 205 6х2х1,13 12,9 272 8х2х1,13 13,9 336 10х2х1,13 16,1 411 12х2х1,13 18,7 505 14х2х1,13 18,7 558 16х2х1,13 19,7 623 20х2х1,13 21,1 742 24х2х1,13 23,7 896 30х2х1,13 26,4 1084 40х2х1,13 30,1 1409 50х2х1,13 33,1 1734 60х2х1,13 36,8 2122 80х2х1,13 41,7 2729 100х2х1,13 45,9 3337 1х2х1,38 7,49 99 2х2х1,38 10,0 163 4х2х1,38 12,4 266 6х2х1,38 14,0 361 8х2х1,38 15,1 451 10х2х1,38 17,6 555 12х2х1,38 20,5 678 14х2х1,38 20,5 758 16х2х1,38 21,6 850 20х2х1,38 23,1 1021 24х2х1,38 26,0 1230 30х2х1,38 29,2 1527 40х2х1,38 33,1 1963 50х2х1,38 37,5 2510 60х2х1,38 40,5 2949 80х2х1,38 45,9 3821 100х2х1,38 50,7 4695