Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVVG
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 7,3 81
5х1,0 8 99
7х1,0 9,2 136
10х1,0 11,3 188
14х1,0 12,2 243
19х1,0 13,5 313
27х1,0 15,9 428
37х1,0 17,7 564
52х1,0 21,1 790
4х1,5 7,9 101
5х1,5 9,2 138
7х1,5 9,9 173
10х1,5 12,2 239
14х1,5 13,2 312
19х1,5 14,6 406
27х1,5 17,3 559
37х1,5 19,7 759
4х2,5 9,4 155
5х2,5 10,2 191
7х2,5 11 243
10х2,5 13,8 339
14х2,5 14,9 450
19х2,5 16,5 590
27х2,5 20,1 837
37х2,5 22,4 1114
4х4 11 227
7х4 13 364
10х4 16,4 511
4х6 12,2 306
7х6 14,5 500
10х6 18,8 722

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for fixed connection to electrical devices and equipment to assemblies of clamps of electrical switch gear with the nominal alternating voltage up to 660V of frequency up to 100 Hz or direct voltage up to 1000V.

The cables of type KVVG are used for installation in the premises, conduits, tunnels, in conditions of aggressive environment, in the absence of mechanical effects on cable.

The class of fire hazard of the cables according to GOST 31565 01.8.2.5.4.

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483, with the cross-section from 0.75 to 6 mm2.

Insulation

PVC-compound.

Core arrangement

From 4 to 61 insulated conductors.

The insulated conductors are twisted, there is a marker pair in each layer.

Separating layer

PVC-compound or a layer with the PET tape.

Over sheath or jacket

PVC-compound.

By category
Control cables
Voltage
660
In execution
For a single pad
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KVVG
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х1,0 7,3 81
5х1,0 8 99
7х1,0 9,2 136
10х1,0 11,3 188
14х1,0 12,2 243
19х1,0 13,5 313
27х1,0 15,9 428
37х1,0 17,7 564
52х1,0 21,1 790
4х1,5 7,9 101
5х1,5 9,2 138
7х1,5 9,9 173
10х1,5 12,2 239
14х1,5 13,2 312
19х1,5 14,6 406
27х1,5 17,3 559
37х1,5 19,7 759
4х2,5 9,4 155
5х2,5 10,2 191
7х2,5 11 243
10х2,5 13,8 339
14х2,5 14,9 450
19х2,5 16,5 590
27х2,5 20,1 837
37х2,5 22,4 1114
4х4 11 227
7х4 13 364
10х4 16,4 511
4х6 12,2 306
7х6 14,5 500
10х6 18,8 722