Products

Search by features


ППГнг(А)-FRHF (PPGng(A)-FRHF)

ППГнг(А)-FRHF (PPGng(A)-FRHF)
Price on request
₽0
By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Shell
Crosslinked polyethylene
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
PPGng(A)-FRHF FE180
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
1х1,5ок-0,66 6,4 61
1х2,5ок-0,66 6,8 74
1х4ок-0,66 7,4 96
1х6ок-0,66 7,9 119
1х10ок-0,66 9,3 176
1х16ок-0,66 10,2 239
1х25ок-0,66 11,8 345
1х35ок-0,66 12,7 445
1х50ок-0,66 14,2 579
2х1,5ок(N)-0,66 13 228
2х2,5ок(N)-0,66 13,7 266
2х4ок(N)-0,66 15,1 334
2х6ок(N)-0,66 16,2 407
2х10ок(N)-0,66 18,6 565
2х16ок(N)-0,66 20,4 732
2х25ок(N)-0,66 23,9 1050
2х35ок(N)-0,66 25,9 1304
2х50ок(N)-0,66 28,8 1667
3х1,5ок(N,PE)-0,66 13,5 256
3х2,5ок(N,PE)-0,66 14,3 304
3х4ок(N,PE)-0,66 16 397
3х6ок(N,PE)-0,66 17 481
3х10ок(N,PE)-0,66 19,6 680
3х16ок(N,PE)-0,66 21,6 900
3х25ок(N,PE)-0,66 25,3 1307
3х35ок(N,PE)-0,66 27,4 1645
3х50ок(N,PE)-0,66 30,5 2122
4х1,5ок(N)-0,66 14,5 297
4х2,5ок(N)-0,66 15,4 357
4х4ок(N)-0,66 17,2 471
PPGng(A)-FRHF FE180
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х6ок(N)-0,66 18,4 580
4х10ок(N)-0,66 21,3 833
4х16ок(N)-0,66 23,9 1139
4х25ок(N)-0,66 27,6 1628
4х35ок(N)-0,66 30 2065
4х50ок(N)-0,66 33,5 2675
5х1,5ок(N,PE)-0,66 15,8 355
5х2,5ок(N,PE)-0,66 16,8 430
5х4ок(N,PE)-0,66 18,6 561
5х6ок(N,PE)-0,66 20 692
5х10ок(N,PE)-0,66 23,6 1028
5х16ок(N,PE)-0,66 26 1376
5х25ок(N,PE)-0,66 30,2 1980
5х35ок(N,PE)-0,66 32,8 2518
5х50ок(N,PE)-0,66 37,2 3312
1х1,5ок-1 6,8 68
1х2,5ок-1 7,2 81
1х4ок-1 8 107
1х6ок-1 8,5 131
1х10ок-1 9,5 181
1х16ок-1 10,4 244
1х25ок-1 12 351
1х35ок-1 12,9 451
1х50ок-1 14,4 586
2х1,5ок(N)-1 13,8 254
2х2,5ок(N)-1 14,5 293
2х4ок(N)-1 16,5 388
2х6ок(N)-1 17,4 456
2х10ок(N)-1 19 583
2х16ок(N)-1 20,8 752
PPGng(A)-FRHF FE180
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
2х25ок(N)-1 24,3 1073
2х35ок(N)-1 26,3 1329
2х50ок(N)-1 29,2 1695
3х1,5ок(N,PE)-1 14,4 286
3х2,5ок(N,PE)-1 15,2 335
3х4ок(N,PE)-1 17,3 449
3х6ок(N,PE)-1 18,3 536
3х10ок(N,PE)-1 20,1 701
3х16ок(N,PE)-1 22 922
3х25ок(N,PE)-1 25,7 1333
3х35ок(N,PE)-1 27,8 1673
3х50ок(N,PE)-1 30,9 2154
4х1,5ок(N)-1 15,5 332
4х2,5ок(N)-1 16,6 402
4х4ок(N)-1 18,7 532
4х6ок(N)-1 19,9 645
4х10ок(N)-1 21,8 857
4х16ок(N)-1 24,4 1166
4х25ок(N)-1 28,1 1659
4х35ок(N)-1 30,4 2099
4х50ок(N)-1 34,4 2747
5х1,5ок(N,PE)-1 16,9 396
5х2,5ок(N,PE)-1 17,9 474
5х4ок(N,PE)-1 20,3 634
5х6ок(N,PE)-1 21,6 768
5х10ок(N,PE)-1 24,1 1057
5х16ок(N,PE)-1 26,6 1408
5х25ок(N,PE)-1 30,7 2017
5х35ок(N,PE)-1 33,4 2558
5х50ок(N,PE)-1 37,7 3357

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power in the fixed networks on the nominal alternating voltage 0.66 and 1kV and frequency 50 Hz.

The cables are used for group installation of cable power lines of safety systems, wiring circuits of fire safety, (the wiring circuits of systems of fire alarm, power of pumps of fire suppression, illuminations of emergency exits and escape routes, smoke removal systems and ventilation, evacuation lifts).

For wiring in the surgical departments of hospitals, of the wiring circuits of emergency power supply of the equipment (current collectors), functioning in case of fire.

The cables of type PPGng(A)-FRHF is designed for group installation of cable lines in cable structures and premises of indoor (closed) electric installation in the absence of danger of mechanical damage during operation.

The class of fire hazard of the cables according to GOST 31565 П1б.1.1.2.1.

STRUCTURE

Conductor

Copper, single-wire or multi-wire core, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483 with the cross-section from 1.5 to 1000 mm2.

Thermal barrier for CCC (current-carrying conductor) (for “FE180” and “FE240”)

The overlapping with two mica tapes.

Insulation

With halogen-free polymer composition.

Core arrangement and twisting

Insulated conductors of 2, 3, 4 and 5 core cables are twisted in a cable core.

Waterproof cables are twisted with water blocking elements.

Inner sheath

It is made in the form of filling of outer gaps between the insulated conductors with the halogen-free polymer composition.

Thermal barrier (for “FE 240”)

Overlapped with mica tapes.

Over sheath or jacket

Of halogen-free polymer composition.

By category
Force cables
Voltage
660 / 1000
In execution
Flame retardant (-ng(А)) / Halogen free (-HF) / Fireproof (-FR)
Insulation
Copper
Shell
Crosslinked polyethylene
Core material
Polymer composition
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
PPGng(A)-FRHF FE180
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
1х1,5ок-0,66 6,4 61
1х2,5ок-0,66 6,8 74
1х4ок-0,66 7,4 96
1х6ок-0,66 7,9 119
1х10ок-0,66 9,3 176
1х16ок-0,66 10,2 239
1х25ок-0,66 11,8 345
1х35ок-0,66 12,7 445
1х50ок-0,66 14,2 579
2х1,5ок(N)-0,66 13 228
2х2,5ок(N)-0,66 13,7 266
2х4ок(N)-0,66 15,1 334
2х6ок(N)-0,66 16,2 407
2х10ок(N)-0,66 18,6 565
2х16ок(N)-0,66 20,4 732
2х25ок(N)-0,66 23,9 1050
2х35ок(N)-0,66 25,9 1304
2х50ок(N)-0,66 28,8 1667
3х1,5ок(N,PE)-0,66 13,5 256
3х2,5ок(N,PE)-0,66 14,3 304
3х4ок(N,PE)-0,66 16 397
3х6ок(N,PE)-0,66 17 481
3х10ок(N,PE)-0,66 19,6 680
3х16ок(N,PE)-0,66 21,6 900
3х25ок(N,PE)-0,66 25,3 1307
3х35ок(N,PE)-0,66 27,4 1645
3х50ок(N,PE)-0,66 30,5 2122
4х1,5ок(N)-0,66 14,5 297
4х2,5ок(N)-0,66 15,4 357
4х4ок(N)-0,66 17,2 471
PPGng(A)-FRHF FE180
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
4х6ок(N)-0,66 18,4 580
4х10ок(N)-0,66 21,3 833
4х16ок(N)-0,66 23,9 1139
4х25ок(N)-0,66 27,6 1628
4х35ок(N)-0,66 30 2065
4х50ок(N)-0,66 33,5 2675
5х1,5ок(N,PE)-0,66 15,8 355
5х2,5ок(N,PE)-0,66 16,8 430
5х4ок(N,PE)-0,66 18,6 561
5х6ок(N,PE)-0,66 20 692
5х10ок(N,PE)-0,66 23,6 1028
5х16ок(N,PE)-0,66 26 1376
5х25ок(N,PE)-0,66 30,2 1980
5х35ок(N,PE)-0,66 32,8 2518
5х50ок(N,PE)-0,66 37,2 3312
1х1,5ок-1 6,8 68
1х2,5ок-1 7,2 81
1х4ок-1 8 107
1х6ок-1 8,5 131
1х10ок-1 9,5 181
1х16ок-1 10,4 244
1х25ок-1 12 351
1х35ок-1 12,9 451
1х50ок-1 14,4 586
2х1,5ок(N)-1 13,8 254
2х2,5ок(N)-1 14,5 293
2х4ок(N)-1 16,5 388
2х6ок(N)-1 17,4 456
2х10ок(N)-1 19 583
2х16ок(N)-1 20,8 752
PPGng(A)-FRHF FE180
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
2х25ок(N)-1 24,3 1073
2х35ок(N)-1 26,3 1329
2х50ок(N)-1 29,2 1695
3х1,5ок(N,PE)-1 14,4 286
3х2,5ок(N,PE)-1 15,2 335
3х4ок(N,PE)-1 17,3 449
3х6ок(N,PE)-1 18,3 536
3х10ок(N,PE)-1 20,1 701
3х16ок(N,PE)-1 22 922
3х25ок(N,PE)-1 25,7 1333
3х35ок(N,PE)-1 27,8 1673
3х50ок(N,PE)-1 30,9 2154
4х1,5ок(N)-1 15,5 332
4х2,5ок(N)-1 16,6 402
4х4ок(N)-1 18,7 532
4х6ок(N)-1 19,9 645
4х10ок(N)-1 21,8 857
4х16ок(N)-1 24,4 1166
4х25ок(N)-1 28,1 1659
4х35ок(N)-1 30,4 2099
4х50ок(N)-1 34,4 2747
5х1,5ок(N,PE)-1 16,9 396
5х2,5ок(N,PE)-1 17,9 474
5х4ок(N,PE)-1 20,3 634
5х6ок(N,PE)-1 21,6 768
5х10ок(N,PE)-1 24,1 1057
5х16ок(N,PE)-1 26,6 1408
5х25ок(N,PE)-1 30,7 2017
5х35ок(N,PE)-1 33,4 2558
5х50ок(N,PE)-1 37,7 3357