Products

Search by features


КуВВ (KuVV)

КуВВ (KuVV)
Price on request
₽0
By category
Wires and cables for electrical installations
Voltage
450
In execution
For a single pad
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KuVV
Number of conductors, nominal cross-section (mm2) Calculated diameter of wire, mm Calculated weight of cable, kg/km
2х0,75 6,7 105
2х1,0 7,1 117
2х1,5 8 147
2х2,5 9,2 196
2х4 10,1 247
2х6 11,1 311
2х10 13,9 491
2х16 17 741
2х25 20,4 1079
2х35 23,1 1422
2х50 27 1921
3х0,75 7,1 155
3х1,0 7,4 172
3х1,5 8,4 215
3х2,5 9,7 283
3х4 10,7 354
3х6 12,2 482
3х10 14,8 698
3х16 12,2 1042
3х25 22,2 1574
3х35 24,6 1988
3х50 28,8 2679
4х0,75 7,6 218
4х1,0 8 241
4х1,5 9,1 299
4х2,5 10,5 391
4х4 12,1 537
4х6 13,3 662
4х10 16,2 951
4х16 19,9 1407
4х25 24,5 2119
4х35 27,2 2664
4х50 31,8 3586
5х0,75 8,3 291
5х1,0 8,7 320
5х1,5 9,9 396
5х2,5 11,5 515
5х4 13,2 706
5х6 14,6 866
5х10 17,8 1235
5х16 22,4 1930
5х25 27 2722
5х35 30,1 3408
5х50 35,2 4583

₽0 for 1 м

Quantity
- + м Add to cart

SCOPE AND PURPOSE

The wires and cables are intended for distribution of electric energy in the electric installations at stationary laying in lighting and power electric networks as well as for installation of electrical equipment, machines, tools and other machines, indoor electric settings, for installation outdoors and in the industrial premises, steel pipes, and hollow channels of building structures, hidden under the plaster lining.

The cables of type KuVV is intended for operation on the nominal alternating voltage up to 300/500V inclusive of nominal frequency up to and including 400 Hz.

The wires and cables are used for single installation.

STRUCTURE

Current-carrying conductor

Copper, of the 1 and 2 class

Number of insulated conductors

2, 3, 4, 5

Range of cross-sections, mm²

0,75-50

Insulation

PVC-compound

Sheath

PVC-compound

By category
Wires and cables for electrical installations
Voltage
450
In execution
For a single pad
Insulation
Copper
Shell
PVC insulation
Core material
Flexible PVC
Number and nom, cross-section of CCC and screens, nxmm2, external diameter, mm, weight of 1km of cable, kg
KuVV
Number of conductors, nominal cross-section (mm2) Calculated diameter of wire, mm Calculated weight of cable, kg/km
2х0,75 6,7 105
2х1,0 7,1 117
2х1,5 8 147
2х2,5 9,2 196
2х4 10,1 247
2х6 11,1 311
2х10 13,9 491
2х16 17 741
2х25 20,4 1079
2х35 23,1 1422
2х50 27 1921
3х0,75 7,1 155
3х1,0 7,4 172
3х1,5 8,4 215
3х2,5 9,7 283
3х4 10,7 354
3х6 12,2 482
3х10 14,8 698
3х16 12,2 1042
3х25 22,2 1574
3х35 24,6 1988
3х50 28,8 2679
4х0,75 7,6 218
4х1,0 8 241
4х1,5 9,1 299
4х2,5 10,5 391
4х4 12,1 537
4х6 13,3 662
4х10 16,2 951
4х16 19,9 1407
4х25 24,5 2119
4х35 27,2 2664
4х50 31,8 3586
5х0,75 8,3 291
5х1,0 8,7 320
5х1,5 9,9 396
5х2,5 11,5 515
5х4 13,2 706
5х6 14,6 866
5х10 17,8 1235
5х16 22,4 1930
5х25 27 2722
5х35 30,1 3408
5х50 35,2 4583