ПуВ (PuV) - Russian analogue of H07V-U ПуГВ (PuGV) - Russian analogue of H07V-K ПуВВ (PuVV) - Russian analogue of H07VVH2-U КуВВ (KuVV) - Russian analogue of H07VV-U КуГВВ (KuGVV) - Russian analogue of H07VV-K

PuV, PuGV, PuVV, PuGVV, KuVV, KuGVV, according to specifications 16-705.501-2010

specifications 16-705.501-2010

Construction Application area Technical data To order
To make an order

You can pre-order the products. After the receipt of your order a specialist of our company will contact you and offer the best delivery conditions.

Type of wire or cable Current-carrying conductor Number of insulated conductors Range of cross-sections, mm2 Insulation Sheath
KuGVV Copper, of the 5 class 2, 3, 4, 5 0,75-50 PVC-compound PVC-compound
KuVV Copper, of the 1 and 2 class 2, 3, 4, 5 0,75-50 PVC-compound PVC-compound
PuGVV Copper, of the 5 class 1 0,5-400 PVC-compound PVC-compound
PuVV Copper, of the 1 and 2 class 1, 2, 3 0,5-400 (0,5-4)* PVC-compound PVC-compound
PuGV Copper, of the 5 class 1 0,5-400 PVC-compound -
PuV Copper, of the 1 and 2 class 1 0,5-400 PVC-compound -

The wires and cables are intended for distribution of electric energy in the electric installations at stationary laying in lighting and power electric networks as well as for installation of electrical equipment, machines, tools and other machines, indoor electric settings, for installation outdoors and in the industrial premises, steel pipes, and hollow channels of building structures, hidden under the plaster lining.

The wire is used for the installation of electrical circuits, power motors, various industrial and laboratory equipment and portable devices. The wires of types PuV, PuGV, PuVV and PuGVV are intended for operation on the nominal alternating voltage up to 450/750V inclusive of nominal frequency up to 400 Hz or on direct voltage up to and including 1000V.

The cables of types KuVV, KuGVV are intended for operation on the nominal alternating voltage up to 300/500V inclusive of nominal frequency up to and including 400 Hz.

The wires and cables are used for single installation.

The class of fire hazard of the cables according to GOST 31565 - 01.8.2.5.4.

Ambient temperature during cable operation , °С from – 50 to + 60
Minimum bending radius, of outer diameters -for wires of types PuV and PuVV and cables of type KuVV 10
-for wires of types PuGV and PuGVV and cables of type KuGVV 5
The ambient temperature for installation of the cables (without preheat), 0C not below - 15

Durable permissible heating temperature conductors during operation, °C

+ 70

To make an order

You can pre-order the products. After the receipt of your order a specialist of our company will contact you and offer the best delivery conditions.

«*»- required fields