ВВГнг(А)-ХЛ (VVGng(A)-KhL) – Russian analogue of NYY Cold Resistance Flame Retardant

VVGng(A)-KhL

Description Add to order

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary electric installations on alternating voltage 0,66 and 1 kV and frequency 50 Hz or for direct voltage of 1 and 1.5 kV correspondingly.

The cables are used for group installation in cable constructions, openair electrical installations (cable overpasses, arcades).

While manufacturing the cables one uses the materials, which allow the cables to be resistant to low temperatures up to – 600C (degrees below zero) are used.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.5.4.

STRUCTURE

Conductor

Copper core of circular of sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

PVC-compound (color coded conductor)

Core arrangement and stranding

Insulated conductors of 2, 3, 4, 5 and 6 core cables twisted in cable core.

Inner sheath

PVC-compound or PVC-compound of low flammability is manufactured with the filling of exterior gaps between insolated conductors.

Cable sheath or jacket

PVC-compound of low flammability

Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
VVGng(A)-KhL 1х1,5ок-0,66 5,3 43
km
VVGng(A)-KhL 1х2,5ок-0,66 5,6 55
km
VVGng(A)-KhL 1х4ок-0,66 6,3 75
km
VVGng(A)-KhL 1х6ок-0,66 6,8 97
km
VVGng(A)-KhL 1х10ок-0,66 8 145
km
VVGng(A)-KhL 1х16ок-0,66 9,1 209
km
VVGng(A)-KhL 1х25ок-0,66 10,6 309
km
VVGng(A)-KhL 1х35ок-0,66 11,6 403
km
VVGng(A)-KhL 1х50ок-0,66 13,1 531
km
VVGng(A)-KhL 2х1,5ок(N)-0,66 8,9 117
km
VVGng(A)-KhL 2х2,5ок(N)-0,66 9,7 147
km
VVGng(A)-KhL 2х4ок(N)-0,66 11 201
km
VVGng(A)-KhL 2х6ок(N)-0,66 12 255
km
VVGng(A)-KhL 2х10ок(N)-0,66 14,4 386
km
VVGng(A)-KhL 2х16ок(N)-0,66 16,2 532
km
VVGng(A)-KhL 2х25ок(N)-0,66 21,3 887
km
VVGng(A)-KhL 2х35ок(N)-0,66 23,6 1148
km
VVGng(A)-KhL 2х50ок(N)-0,66 26,6 1490
km
VVGng(A)-KhL 3х1,5ок(N,PE)-0,66 9,3 136
km
VVGng(A)-KhL 3х2,5ок(N,PE)-0,66 10,1 175
km
VVGng(A)-KhL 3х4ок(N,PE)-0,66 11,6 243
km
VVGng(A)-KhL 3х6ок(N,PE)-0,66 12,6 314
km
VVGng(A)-KhL 3х10ок(N,PE)-0,66 15,2 482
km
VVGng(A)-KhL 3х16ок(N,PE)-0,66 17,1 678
km
VVGng(A)-KhL 3х25ок(N,PE)-0,66 22,5 1121
km
VVGng(A)-KhL 3х35ок(N,PE)-0,66 25 1465
km
VVGng(A)-KhL 3х50ок(N,PE)-0,66 28,1 1916
km
VVGng(A)-KhL 4х1,5ок(N)-0,66 10 160
km
VVGng(A)-KhL 4х2,5ок(N)-0,66 10,9 209
km
VVGng(A)-KhL 4х4ок(N)-0,66 12,5 294
km
VVGng(A)-KhL 4х6ок(N)-0,66 13,7 385
km
VVGng(A)-KhL 4х10ок(N)-0,66 16,6 601
km
Number of conductors, nominal cross-section (mm2), construction, voltage (kV) Calculated diameter of cable, mm Calculated weight of cable, kg/km
VVGng(A)-KhL 4х16ок(N)-0,66 18,8 855
km
VVGng(A)-KhL 4х25ок(N)-0,66 24,9 1427
km
VVGng(A)-KhL 4х35ок(N)-0,66 27,3 1843
km
VVGng(A)-KhL 4х50ок(N)-0,66 30,8 2418
km
VVGng(A)-KhL 5х1,5ок(N,PE)-0,66 10,8 189
km
VVGng(A)-KhL 5х2,5ок(N,PE)-0,66 11,8 250
km
VVGng(A)-KhL 5х4ок(N,PE)-0,66 13,6 356
km
VVGng(A)-KhL 5х6ок(N,PE)-0,66 14,9 470
km
VVGng(A)-KhL 5х10ок(N,PE)-0,66 18,2 731
km
VVGng(A)-KhL 5х16ок(N,PE)-0,66 20,6 1042
km
VVGng(A)-KhL 5х25ок(N,PE)-0,66 27,2 1731
km
VVGng(A)-KhL 5х35ок(N,PE)-0,66 29,8 2249
km
VVGng(A)-KhL 5х50ок(N,PE)-0,66 34,2 2996
km
VVGng(A)-KhL 1х1,5ок-1 5,7 48
km
VVGng(A)-KhL 1х2,5ок-1 6 60
km
VVGng(A)-KhL 1х4ок-1 6,9 84
km
VVGng(A)-KhL 1х6ок-1 7,4 106
km
VVGng(A)-KhL 1х10ок-1 8,2 149
km
VVGng(A)-KhL 1х16ок-1 9,3 213
km
VVGng(A)-KhL 1х25ок-1 10,8 314
km
VVGng(A)-KhL 1х35ок-1 11,8 408
km
VVGng(A)-KhL 1х50ок-1 13,3 536
km
VVGng(A)-KhL 2х1,5ок(N)-1 9,7 134
km
VVGng(A)-KhL 2х2,5ок(N)-1 10,5 166
km
VVGng(A)-KhL 2х4ок(N)-1 12,2 233
km
VVGng(A)-KhL 2х6ок(N)-1 13,2 290
km
VVGng(A)-KhL 2х10ок(N)-1 14,8 399
km
VVGng(A)-KhL 2х16ок(N)-1 16,6 547
km
VVGng(A)-KhL 2х25ок(N)-1 21,7 906
km
VVGng(A)-KhL 2х35ок(N)-1 24 1170
km
VVGng(A)-KhL 2х50ок(N)-1 27 1514
km
VVGng(A)-KhL 3х1,5ок(N,PE)-1 10,2 155
km
3х2,5ок    