АВБШвнг(А)-ХЛ (АVBShvng(A)–KhL) – Russian analogue of NYIFY Cold Resistance Flame Retardant

АVBShvng(A)–KhL

Description Add to order

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary electric installations on alternating voltage 0,66 and 1 kV and frequency 50 Hz or for direct voltage of 1 and 1.5 kV correspondingly.

The cables are used for group installation in cable constructions, openair electrical installations (cable overpasses, arcades).

While manufacturing the cables one uses the materials, which allow the cables to be resistant to low temperatures up to – 600C (degrees below zero) are used.

The class of fire hazard of the cables according to GOST 31565 П1б.8.2.5.4.

STRUCTURE

Conductor

Aluminum core of circular of sector-shaped form, of the 1 or 2 class according to GOST 22483.

Insulation

PVC-compound (color coded conductor)

Core arrangement and stranding

Insulated conductors of 2, 3, 4, 5 and 6 core cables twisted in cable core.

In cables of types VVG-Png(A)-KhL and AVVG-Png(A)-KhL the cores are situated in parallel in flat formation.

Inner sheath

PVC-compound or PVC-compound of low flammability is manufactured with the filling of exterior gaps between insolated conductors.

Cable armoring

For cables of types АVBShvng(A)–KhL cable armoring is laid helically with two steel, galvanized tapes.

Cable sheath or jacket

PVC-compound of low flammability

Number and nominal cross-section of conductors, mm2 Outer diameter, mm Weight of 1km of cable, kg
АVBShvng(A)–KhL 2x1,5 - -
m
АVBShvng(A)–KhL 2x2,5 13,1 251
m
АVBShvng(A)–KhL 2x4 14,4 303
m
АVBShvng(A)–KhL 2x6 15,4 345
m
АVBShvng(A)–KhL 2x10 18 458
m
АVBShvng(A)–KhL 2x16 19,8 556
m
АVBShvng(A)–KhL 2x25 22,9 735
m
АVBShvng(A)–KhL 2x35 25,4 902
m
АVBShvng(A)–KhL 2x50 28,4 1116
m
АVBShvng(A)–KhL 3x1,5 - -
m
АVBShvng(A)–KhL 3x2,5 13,5 270
m
АVBShvng(A)–KhL 3x4 15 327
m
АVBShvng(A)–KhL 3x6 16 377
m
АVBShvng(A)–KhL 3x10 18,8 504
m
АVBShvng(A)–KhL 3x16 20,8 622
m
АVBShvng(A)–KhL 3x25 24,5 852
m
АVBShvng(A)–KhL 3x35 26,8 1028
m
АVBShvng(A)–KhL 3x50 29,9 1279
m
АVBShvng(A)–KhL 4x1,5 - -
m
АVBShvng(A)–KhL 4x2,5 14,3 301
m
АVBShvng(A)–KhL 4x4 15,9 370
m
АVBShvng(A)–KhL 4x6 17,1 426
m
АVBShvng(A)–KhL 4x10 20,2 584
m
АVBShvng(A)–KhL 4x16 22,4 725
m
АVBShvng(A)–KhL 4x25 26,7 1016
m
АVBShvng(A)–KhL 4x35 29,1 1218
m
АVBShvng(A)–KhL 4x50 32,6 1525
m
АVBShvng(A)–KhL 5x1,5 - -
m
АVBShvng(A)–KhL 5x2,5 15,2 338
m
АVBShvng(A)–KhL 5x4 17 420
m
АVBShvng(A)–KhL 5x6 18,5 490
m
АVBShvng(A)–KhL 5x10 21,8 673
m
АVBShvng(A)–KhL 5x16 24,6 860
m
АVBShvng(A)–KhL 5x25 29 1187
m
АVBShvng(A)–KhL 5x35 31,6 1437
m
АVBShvng(A)–KhL 5x50 36 1843
m
Number and nominal cross-section of conductors, mm2 Outer diameter, mm Weight of 1km of cable, kg
АVBShvng(A)–KhL 2x1,5 - -
m
АVBShvng(A)–KhL 2x2,5 13,9 278
m
АVBShvng(A)–KhL 2x4 15,6 350
m
АVBShvng(A)–KhL 2x6 16,6 393
m
АVBShvng(A)–KhL 2x10 18,4 474
m
АVBShvng(A)–KhL 2x16 20,2 574
m
АVBShvng(A)–KhL 2x25 23,3 757
m
АVBShvng(A)–KhL 2x35 25,8 926
m
АVBShvng(A)–KhL 2x50 28,8 1140
m
АVBShvng(A)–KhL 2x70 27 1094
m
АVBShvng(A)–KhL 2x95 29,9 1340
m
АVBShvng(A)–KhL 2x120 32,2 1560
m
АVBShvng(A)–KhL 2x150 35,4 1866
m
АVBShvng(A)–KhL 2x185 38,3 2180
m
АVBShvng(A)–KhL 2x240 42,4 2666
m
АVBShvng(A)–KhL 3x1,5 - -
m
АVBShvng(A)–KhL 3x2,5 14,4 301
m
АVBShvng(A)–KhL 3x4 16,3 380
m
АVBShvng(A)–KhL 3x6 17,5 433
m
АVBShvng(A)–KhL 3x10 19,2 526
m
АVBShvng(A)–KhL 3x16 21,2 641
m
АVBShvng(A)–KhL 3x25 24,9 879
m
АVBShvng(A)–KhL 3x35 27,2 1055
m
АVBShvng(A)–KhL 3x50 30,3 1310
m
АVBShvng(A)–KhL 3x70 31,3 1439
m
АVBShvng(A)–KhL 3x95 35,2 1820
m
АVBShvng(A)–KhL 3x120 38 2131
m
АVBShvng(A)–KhL 3x150 41,3 2511
m
АVBShvng(A)–KhL 3x185 45,3 3000
m
АVBShvng(A)–KhL 3x240 50,3 3692
m
АVBShvng(A)–KhL 4x1,5 - -
m
АVBShvng(A)–KhL 4x2,5 14,3 336
m
АVBShvng(A)–KhL 4x4 15,3 431
m
АVBShvng(A)–KhL 4x6 17,6 495
m
АVBShvng(A)–KhL 4x10 20,7 608
m
АVBShvng(A)–KhL 4x16 22,9 749
m
АVBShvng(A)–KhL 4x25 27,2 1045
m
АVBShvng(A)–KhL 4x35 29,5 1249
m
АVBShvng(A)–KhL 4x50 33,1 1558
m
АVBShvng(A)–KhL 4x70 35,7 1830
m
АVBShvng(A)–KhL 4x95 39,8 2283
m
АVBShvng(A)–KhL 4x120 43,1 2678
m
АVBShvng(A)–KhL 4x150 47,3 3207
m
АVBShvng(A)–KhL 4x185 51,4 3804
m
АVBShvng(A)–KhL 4x240 57,7 4761
m
АVBShvng(A)–KhL 5x1,5 - -
m
АVBShvng(A)–KhL 5x2,5 16,3 379
m
АVBShvng(A)–KhL 5x4 18,8 491
m
АVBShvng(A)–KhL 5x6 20,2 566
m
АVBShvng(A)–KhL 5x10 22,3 703
m
АVBShvng(A)–KhL 5x16 25,2 891
m
АVBShvng(A)–KhL 5x25 29,5 1222
m
АVBShvng(A)–KhL 5x35 32,2 1472
m
АVBShvng(A)–KhL 5x50 36,5 1879
m
АVBShvng(A)–KhL 5x70 39,3 2188
m
АVBShvng(A)–KhL 5x95 44 2745
m
АVBShvng(A)–KhL 5x120 48 3269
m
АVBShvng(A)–KhL 5x150 52,3 3866
m
АVBShvng(A)–KhL 5x185 57,3 4639
m
АVBShvng(A)–KhL 5x240 61,5 5776
m